Andrea Cicconetti

Prof. Dr. Andrea Cicconetti

university "sapienza" rome

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Alessio ZanzaAlessio Zanza
Alessio Zanza
AMAlessandro Mazzoni
Alessandro Mazzoni
ACAndrea Cicconetti
Andrea Cicconetti
Luca TestarelliLuca Testarelli
Luca Testarelli
Dario Di NardoDario Di Nardo
Dario Di Nardo
This narrative review aims to evaluate the current evidence for the application of magnetic resonance imaging (MRI), a radiation-free diagnostic exam, in some fields of dentistry. Background: Radiographic imaging plays a significant role in current first and second level dental diagnostics and treatment planning. However, the main disadvantage is the high exposure to ionizing radiation for patients. Methods: A search for articles on dental MRI was performed using the PubMed electronic database, and 37 studies were included. Only some articles about endodontics, conservative dentistry, implantology, and oral and craniofacial surgery that best represented the aim of this study were selected. Results: All the included articles showed that MRI can obtain well-defined images, which can be applied in operative dentistry. Conclusions: This review highlights the potential of MRI for diagnosis in dental clinical practice, without the risk of biological damage from continuous ionizing radiation exposure.

21 October 2013 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SASusanna Annibali
Susanna Annibali
DBDiana Bellavia
Diana Bellavia
LOLivia Ottolenghi
Livia Ottolenghi
ACAndrea Cicconetti
Andrea Cicconetti
MCMaria Paola Cristalli
Maria Paola Cristalli
APAndrea Pilloni
Andrea Pilloni

1 November 2007 in Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology
Verified
Journal Article
Closed access
ACAndrea Cicconetti
Andrea Cicconetti
BSBenedetto Sacchetti
Benedetto Sacchetti
ABAdriano Bartoli
Adriano Bartoli
SMStefano Michienzi
Stefano Michienzi
ACAlessandro Corsi
Alessandro Corsi
MRMara Riminucci
Mara Riminucci

14 November 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Alessio ZanzaAlessio Zanza
Alessio Zanza
ACAndrea Cicconetti
Andrea Cicconetti
SBShilpa Bhandi
Shilpa Bhandi
GMGabriele Miccoli
Gabriele Miccoli
Dario Di NardoDario Di Nardo
Dario Di Nardo
(1) Background: the frequency with which diagnostic tests are prescribed with exposure to ionizing radiation, a cause of biological damage, has been studied, and with much more attention, patients are subjected to these diagnostic tests for diagnosis and follow-up. This review aimed, given the recent developments of this technology, to evaluate the possible use of ultrasound in different branches of dentistry. The possibility of applying ionizing-radiation-free diagnostic exams in dentistry, overcoming the limits of this application, has led scientific research in this area to obtain interesting results that bode well for the future. (2) Methods: a search for articles on the application of ultrasounds in dentistry was performed using the PubMed electronic database. (3) Results: only 32 studies were included, and these clearly stated that this examination is widely usable and in great progress. (4) Conclusions: regarding the modern application techniques of this diagnostic test, it is essential to consider technological evolution as an objective to reduce the damage and side effects of necessary diagnostic tests. The use of ultrasound in dentistry can represent a valid radiation-free alternative, in certain contexts, to the other most used exams.

17 January 2022 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Alessio ZanzaAlessio Zanza
Alessio Zanza
ACAndrea Cicconetti
Andrea Cicconetti
SBShilpa Bhandi
Shilpa Bhandi
RGRenzo Guarnieri
Renzo Guarnieri
Dario Di NardoDario Di Nardo
Dario Di Nardo
Background: The most used types of retention of implant-supported prostheses are screw-retained or cement-retained restorations. The advantages and disadvantages of both have been identified by various authors over the years. However, cement-retained implant crowns and fixed partial dentures are among the most used types of restorations in implant prostheses, due to their aesthetic and clinical advantages. When cemented prostheses are made on implants, the problem of cement residues is important and often associated with biological implant pathologies. The objective of this research was to establish to what extent the techniques to reduce excess cement really affect the volume of cement residues. Materials and Methods: This review was written following the PRISMA statement; a detailed search was carried out in three different electronic databases—PubMed, Scopus, and Cochrane Library. The inclusion criteria were prospective clinical studies, with at least 10 participants per group, and with at least 6 months of the follow-up period. Results: There have been many proposals for techniques supposed to reduce the amount of excess cement in the peri-implant sulcus and on the prosthetic components, but of these, which are exceptional in their in vitro capabilities, very few have been clinically validated, and this represents the real limitation and a great lack of knowledge regarding this topic. Three articles met the inclusion criteria, which were analyzed and compared, to obtain the information necessary for the purposes of the systematic review. Discussion: Extraoral cementation can reduce the excess cement, which, after a normal excess removal procedure, is, nevertheless, of such size that it does not affect the possibility of peri-implant pathologies developing. All these studies concluded that a small amount of cement residue is found in the gingival sulcus, and using eugenol-free oxide cements, the residues were only deposited on the metal surfaces, with a better peri-implant tissues health. Conclusion: Despite the limitations of this study, it was possible to carefully analyze these characteristics and obtain valuable suggestions for daily clinical practice. Resinous cements are considered, due to the free monomers present in them, toxic for the soft tissues. The provisional zinc-oxide cements, also eugenol-free, represent the ideal choice. The different grades of retentive forces provided by these cements do not seem to have clinical effects on the decementation of restorations.

13 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gianluca GambariniGianluca Gambarini
Gianluca Gambarini
ACAndrea Cicconetti
Andrea Cicconetti
Dario Di NardoDario Di Nardo
Dario Di Nardo
GMGabriele Miccoli
Gabriele Miccoli
Alessio ZanzaAlessio Zanza
Alessio Zanza
MSMarco Seracchiani
Marco Seracchiani
Protaper Universal (PTU), Protaper Gold (PTG) (Maillefer, Ballaigues, CH), EdgeTaper (ET), and EdgeTaper Platinum (ETP) (Albuquerque, NM, USA) were tested for both torsional and flexural resistance. The aim of the present study was to evaluate the influence of proprietary heat treatment on the metallurgical properties of the aforementioned instruments. Four groups of 30 different instruments (size 20.07) were tested, then divided into two subgroups of 15 instruments—one for the cyclic fatigue test in a curved canal (90°—2 mm radius) at 300 rpm and 2.5 Ncm. The time to fracture (TtF) and fragment length (FL) were recorded. The other subgroup was subjected to the torsional test (300 rpm, 5.5 Ncm). The torque to fracture and TtF were recorded. All the instruments underwent a SEM analysis. The heat-treated instruments showed a significantly higher fatigue resistance than the non-heat-treated instruments (p < 0.05). No significant differences were found in the torsional resistance between the ET and PTU, and the ETP and PTG. However, when comparing all the groups, the heat-treated instruments showed less torsional resistance. The improvement from heat treatment was mainly found in the cyclic fatigue resistance.