Renzo Guarnieri

Dr. Renzo Guarnieri

Department of Oral and Maxillofacial Sciences, School of Dentistry, University La Sapienza, Rome, Italy
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 January 2022 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Alessio ZanzaAlessio Zanza
Alessio Zanza
ACAndrea Cicconetti
Andrea Cicconetti
SBShilpa Bhandi
Shilpa Bhandi
RGRenzo Guarnieri
Renzo Guarnieri
Dario Di NardoDario Di Nardo
Dario Di Nardo
Background: The most used types of retention of implant-supported prostheses are screw-retained or cement-retained restorations. The advantages and disadvantages of both have been identified by various authors over the years. However, cement-retained implant crowns and fixed partial dentures are among the most used types of restorations in implant prostheses, due to their aesthetic and clinical advantages. When cemented prostheses are made on implants, the problem of cement residues is important and often associated with biological implant pathologies. The objective of this research was to establish to what extent the techniques to reduce excess cement really affect the volume of cement residues. Materials and Methods: This review was written following the PRISMA statement; a detailed search was carried out in three different electronic databases—PubMed, Scopus, and Cochrane Library. The inclusion criteria were prospective clinical studies, with at least 10 participants per group, and with at least 6 months of the follow-up period. Results: There have been many proposals for techniques supposed to reduce the amount of excess cement in the peri-implant sulcus and on the prosthetic components, but of these, which are exceptional in their in vitro capabilities, very few have been clinically validated, and this represents the real limitation and a great lack of knowledge regarding this topic. Three articles met the inclusion criteria, which were analyzed and compared, to obtain the information necessary for the purposes of the systematic review. Discussion: Extraoral cementation can reduce the excess cement, which, after a normal excess removal procedure, is, nevertheless, of such size that it does not affect the possibility of peri-implant pathologies developing. All these studies concluded that a small amount of cement residue is found in the gingival sulcus, and using eugenol-free oxide cements, the residues were only deposited on the metal surfaces, with a better peri-implant tissues health. Conclusion: Despite the limitations of this study, it was possible to carefully analyze these characteristics and obtain valuable suggestions for daily clinical practice. Resinous cements are considered, due to the free monomers present in them, toxic for the soft tissues. The provisional zinc-oxide cements, also eugenol-free, represent the ideal choice. The different grades of retentive forces provided by these cements do not seem to have clinical effects on the decementation of restorations.

24 August 2020 in Prosthesis
Verified
Journal Article
Open access
PDF file
LPLuigi Paracchini
Luigi Paracchini
CBChristian Barbieri
Christian Barbieri
MRMattia Redaelli
Mattia Redaelli
DCDomenico Di Croce
Domenico Di Croce
CVcorrado vincenzi
corrado vincenzi
RGRenzo Guarnieri
Renzo Guarnieri
Dental implant macro- and micro-shape should be designed to maximize the delivery of optimal favorable stresses in the surrounding bone region. The present study aimed to evaluate the stress distribution in cortical and cancellous bone surrounding two models of dental implants with the same diameter and length (4.0 × 11 mm) and different implant/neck design and thread patterns. Sample A was a standard cylindric implant with cylindric neck and V-shaped threads, and sample B was a new conical implant with reverse conical neck and with “nest shape” thread design, optimized for the favorable stress distribution in the peri-implant marginal bone region. Materials and methods: The three-dimensional model was composed of trabecular and cortical bone corresponding to the first premolar mandibular region. The response to static forces on the samples A and B were compared by finite element analysis (FEA) using an axial load of 100 N and an oblique load of 223.6 N (resulting from a vertical load of 100 N and a horizontal load of 200 N). Results: Both samples provided acceptable results under loadings, but the model B implant design showed lower strain values than the model A implant design, especially in cortical bone surrounding the neck region of the implant. Conclusions: Within the limitation of the present study, analyses suggest that the new dental implant design may minimize the transfer of stress to the peri-implant cortical bone.

1 July 2014 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
SPSabrina Pappalardo
Sabrina Pappalardo
RGRenzo Guarnieri
Renzo Guarnieri

26 October 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
RGRenzo Guarnieri
Renzo Guarnieri
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Alessio ZanzaAlessio Zanza
Alessio Zanza
GMGabriele Miccoli
Gabriele Miccoli
Dario Di NardoDario Di Nardo
Dario Di Nardo
Luca TestarelliLuca Testarelli
Luca Testarelli
The aim of this retrospective study was to investigate the relationship between the amount of early bone remodeling, the marginal bone loss (MBL) progression, and the peri-implant sulcular fluid concentration of active metalloproteinase-8 (a-MMP-8) and the incidence of peri-implantitis (P) over 5 years of implant function. It has been documented that dental implants with a high degree of early marginal bone loss (MBL) are likely to achieve additional increased MBL during function. Moreover, it has been speculated that early increased MBL might be a predictive factor for the subsequent onset of peri-implant inflammatory diseases. Clinical and radiographic data at implant placement (T0) and restoration delivery (TR) at 6 months (T1), 2 years (T2), and 5 years (T5) post-loading were retrospectively collected. MBL levels/rates (MBLr) and peri-implant sulcular fluid levels/rates of a-MMP-8 were assessed at TR, T1, T2, and T5. Implants were divided into two groups: group 1 with peri-implantitis (P+) and group 2 without peri-implantitis (P−). A multi-level simple binary logistic regression, using generalized estimation equations (GEEs), was implemented to assess the association between each independent variable and P+. A receiver operating characteristics (ROC) curve was used to evaluate an optimal cutoff point for T1 MBL degree and a-MMP-8 level to discriminate between P+ and P− implants. A total of 80 patients who had received 80 implants between them (39 implants with a laser-microtextured collar surface (LMS) and 41 implants with a machined collar surface (MS)) were included. Periapical radiographs and a software package were used to measure MBL rates. Peri-implant sulcular implant fluid samples were analyzed by a chairside mouth-rinse test (ImplantSafe®) in combination with a digital reader (ORALyzer®). Twenty-four implants (six with an LMS and eighteen with an MS) were classified as P+. No statistically significant association was found between the amount of early bone remodeling, MBL progression, and MBLr and the incidence of peri-implantitis. Implants with a-MMP-8 levels >15.3 ng/mL at T1 presented a significantly higher probability of P+. The amount of early marginal bone remodeling cannot be considered as an indicator of the subsequent onset of P, whereas high a-MMP-8 levels 6 months after loading could have a distinct ability to predict P.

8 October 2021 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
RGRenzo Guarnieri
Renzo Guarnieri
GMGabriele Miccoli
Gabriele Miccoli
RRRodolfo Reda
Rodolfo Reda
AMAlessandro Mazzoni
Alessandro Mazzoni
DNDario Di Nardo
Dario Di Nardo
LTLuca Testarelli
Luca Testarelli

5 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
RGRenzo Guarnieri
Renzo Guarnieri
Rodolfo RedaRodolfo Reda
Rodolfo Reda
Dario Di NardoDario Di Nardo
Dario Di Nardo
GMGabriele Miccoli
Gabriele Miccoli
Alessio ZanzaAlessio Zanza
Alessio Zanza
Luca TestarelliLuca Testarelli
Luca Testarelli
Aim: The aim of the present study was to compare the direct and indirect cytotoxicity of a porcine dried acellular dermal matrix (PDADM) versus a porcine hydrated acellular dermal matrix (PHADM) in vitro. Both are used for periodontal and peri-implant soft tissue regeneration. Materials and methods: Two standard direct cytotoxicity tests—namely, the Trypan exclusion method (TEM) and the reagent WST-1 test (4-3-[4-iodophenyl]-2-[4-nitrophenyl]-2H-[5-tetrazolio]-1,3-benzol-desulphonated)—were performed using human primary mesenchymal stem cells (HPMSCs) seeded directly onto a PDADM and PHADM after seven days. Two standard indirect cytotoxicity tests—namely, lactate dehydrogenase (LTT) and MTT (3-[4,5-dimethyl-2-thiazolyl]-2,5-diphenyl-2H-tetrazoliumbromide)—were performed using HPMSCs cultivated in eluates from the matrices incubated for 0.16 h (10 min), 1 h, and 24 h in a serum-free cell culture medium. Results: The WST and the TEM tests revealed significantly lower direct cytotoxicity values of HPMSCs on the PHADM compared with the PDADM. The indirect cytotoxicity levels were low for both the PHADM and PDADM, peaking in short-term eluates and decreasing with longer incubation times. However, they were lower for the PHADM with a statistically significant difference (p < 0.005). Conclusions: The results of the current study demonstrated a different biologic behavior between the PHADM and the PDADM, with the hydrated form showing a lower direct and indirect cytotoxicity.