Expanding metabolome coverage to include complex lipids and polar metabolites is essential in the generation of well-founded hypotheses in biological assays. Traditionally, lipid extraction is performed by liquid-liquid extraction using either methyl-tert-butyl ether (MTBE) or chloroform, and polar metabolite extraction using methanol. Here, we evaluated the performance of single-step sample preparation methods for simultaneous extraction of the complex lipidome and polar metabolome from human plasma. The method performance was evaluated using high-coverage Hydrophilic Interaction Liquid Chromatography-ESI coupled to tandem mass spectrometry (HILIC-ESI-MS/MS) methodology targeting a panel of 1159 lipids and 374 polar metabolites. The criteria used for method evaluation comprised protein precipitation efficiency, and relative MS signal abundance and repeatability of detectable lipid and polar metabolites in human plasma. Among the tested methods, the isopropanol (IPA) and 1-butanol:methanol (BUME) mixtures were selected as the best compromises for the simultaneous extraction of complex lipids and polar metabolites, allowing for the detection of 584 lipid species and 116 polar metabolites. The extraction with IPA showed the greatest reproducibility with the highest number of lipid species detected with the coefficient of variation (CV) < 30%. Besides this difference, both IPA and BUME allowed for the high-throughput extraction and reproducible measurement of a large panel of complex lipids and polar metabolites, thus warranting their application in large-scale human population studies.
1 November 2017 in International Journal of Analytical Chemistry
The sensorial properties of Colombian coffee are renowned worldwide, which is reflected in its market value. This raises the threat of fraud by adulteration using coffee grains from other countries, thus creating a demand for robust and cost-effective methods for the determination of geographical origin of coffee samples. Spectroscopic techniques such as Nuclear Magnetic Resonance (NMR), near infrared (NIR), and mid-infrared (mIR) have arisen as strong candidates for the task. Although a body of work exists that reports on their individual performances, a faithful comparison has not been established yet. We evaluated the performance of 1H-NMR, Attenuated Total Reflectance mIR (ATR-mIR), and NIR applied to fraud detection in Colombian coffee. For each technique, we built classification models for discrimination by species (C. arabica versus C. canephora (or robusta)) and by origin (Colombia versus other C. arabica) using a common set of coffee samples. All techniques successfully discriminated samples by species, as expected. Regarding origin determination, ATR-mIR and 1H-NMR showed comparable capacity to discriminate Colombian coffee samples, while NIR fell short by comparison. In conclusion, ATR-mIR, a less common technique in the field of coffee adulteration and fraud detection, emerges as a strong candidate, faster and with lower cost compared to 1H-NMR and more discriminating compared to NIR.
18 July 2016 in Journal of Analytical Methods in Chemistry
In a previous work using1H-NMR we reported encouraging steps towards the construction of a robust expert system for the discrimination of coffees from Colombia versus nearby countries (Brazil and Peru), to assist the recent protected geographical indication granted to Colombian coffee in 2007. This system relies on fingerprints acquired on a 400 MHz magnet and is thus well suited for small scale random screening of samples obtained at resellers or coffee shops. However, this approach cannot easily be implemented at harbour’s installations, due to the elevated operational costs of cryogenic magnets. This limitation implies shipping the samples to the NMR laboratory, making the overall approach slower and thereby more expensive and less attractive for large scale screening at harbours. In this work, we report on our attempt to obtain comparable classification results using alternative techniques that have been reported promising as an alternative to NMR: GC-MS and GC-C-IRMS. Although statistically significant information could be obtained by all three methods, the results show that the quality of the classifiers depends mainly on the number of variables included in the analysis; hence NMR provides an advantage since more molecules are detected to obtain a model with better predictions.
Lipid metabolism and circulatory lipid levels are tightly associated with the (cardio)metabolic health. Consequently, MS-based lipidomics has emerged as a powerful phenotyping tool in epidemiological, human population, and in clinical intervention studies. However, ensuring high-throughput and reproducible measurement of a wide panel of circulatory lipid species in large-scale studies poses a significant challenge. Here, we applied a recently developed quantitative LC-MS/MS lipidomics approach to a subset of 1,086 fasted plasma samples belonging to apparently healthy participants from prospective Lausanne population study. This high-coverage and high-throughput hydrophilic interaction liquid chromatography-based methodology allowed for the robust measurement of 782 circulatory lipid species spanning 22 lipid classes and six orders of magnitude-wide concentration range. This was achieved by combining semiautomated sample preparation using a stable isotope dilution approach and the alternate analysis of National Institute of Standards and Technology plasma reference material, as a quality control. Based on National Institute of Standards and Technology quality control analysis, median between-batch reproducibility was 8.5%, over the course of analysis of 13 independent batches comprising 1,086 samples collected from 364 individuals at three time points. Importantly, the biological variability, per lipid species, was significantly higher than the batch-to-batch analytical variability. Furthermore, the significantly lower between-subject (than within-subject) variability and unsupervised sample clustering demonstrated the high individuality and sex specificity of circulatory lipidome. The most prominent sex differences were reported for sphingomyelins and ether-linked phospholipids present in significantly higher concentrations in female plasma. The high individuality and sex specificity of circulatory lipidome constitute important pre-requisites for the application of lipidomics in next-generation metabolic health monitoring.
Between 2012 and 2014, 715 green coffee samples were gathered by Almacafé S.A. (Bogotá, Colombia) from 27 countries. These were analysed at the nuclear magnetic resonance (NMR) laboratory at Universidad del Valle (Cali, Colombia). Over 1000 methanolic coffee extracts were prepared and 4563 spectra were acquired in a fully automatic manner using a 400 MHz NMR spectrometer (Bruker Biospin, Germany). The dataset spans the variance that could be expected for an industrial application of origin monitoring, including samples from different harvest times, collected over several years, and processed by at least two distinct operators. The resulting 1D and 2D spectra can be used to develop and evaluate feature extraction methods, multivariate algorithms, and automation monitoring techniques. They can also be used as datasets for teaching, or as a reference for new studies of similar samples and approaches.
Lipid analysis at the molecular species level represents a valuable opportunity for clinical applications due to the essential roles that lipids play in metabolic health. However, a comprehensive and high-throughput lipid profiling remains challenging given the lipid structural complexity and exceptional diversity. Herein, we present an ‘omic-scale targeted LC-MS/MS approach for the straightforward and high-throughput quantification of a broad panel of complex lipid species across 21 lipid (sub)classes. The workflow involves an automated single-step extraction with 2-propanol, followed by lipid analysis using Hydrophilic Interaction Liquid Chromatography (HILIC) in a dual-column setup coupled to tandem mass spectrometry with data acquisition in timed-selective reaction monitoring (t-SRM) mode (12 min total run time). The analysis pipeline consists of an initial screen of 1922 lipid species, followed by high-throughput quantification of robustly detected species. Lipid quantification is achieved by a single-point calibration with 75 isotopically labeled standards representative of different lipid classes, covering lipid species with diverse acyl/alkyl chain lengths and unsaturation degrees. When applied to human plasma, 807 lipid species were measured with median intra- and inter-day precision of 9.5 % and 13.6 %, respectively, evaluated within a single and across multiple batches. The concentration ranges measured in NIST plasma were in accordance with the consensus intervals determined in previous ring-trials. Finally, to benchmark our workflow, we characterized NIST plasma materials with different clinical and ethnic backgrounds and analyzed a sub-set of sera (n=81) from a clinically healthy elderly population. Our quantitative lipidomic platform allowed for a clear distinction between different NIST materials and revealed the sex-specificity of the serum lipidome, highlighting numerous statistically significant sex differences.