Aditya Suryadi Tan

Mr. Aditya Suryadi Tan

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BKBo-Gyu Kim
Bo-Gyu Kim
DYDal-Seong Yoon
Dal-Seong Yoon
GKGi Woo Kim
Gi Woo Kim
Seung-Bok ChoiSeung-Bok Choi
Seung-Bok Choi
ATAditya Suryadi Tan
Aditya Suryadi Tan
TSThomas Sattel
Thomas Sattel
In this study, a new class of magnetorheological (MR) damper, which can realize desired damping force at both low and high speeds of vehicle suspension systems, is proposed and its salient characteristics are shown through computer simulations. Unlike conventional MR dampers, the proposed MR damper has a specific pole shape function and therefore the damping coefficient is changed by varying the effective area of the main orifice. In addition, by controlling the opening or closing the bypass orifice, the drastic change of the damping coefficient is realizable. After briefly describing the operating principle, a mathematical modeling is performed considering the pole shape function which is a key feature of the proposed MR damper. Then, the field-dependent damping force and piston velocity-dependent characteristics are presented followed by an example on how to achieve desired damping force characteristics by changing the damping coefficient and slope breaking point which represents the bilinear damping property.

21 May 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
ATAditya Suryadi Tan
Aditya Suryadi Tan
JBJohannes Belkner
Johannes Belkner
ASAdrian Stroschke
Adrian Stroschke
TSThomas Sattel
Thomas Sattel
A digital ER-valve with a segmentation of its electrode in the parallel direction to the flow leads to a change in the gradient of the volume flow rate-pressure difference characteristic in both valve’s ends. When such a valve is used in a damper, it presents an opportunity to have a damper with an adjustable damping constant. Despite its promising features, there is no experimental investigation yet found for this kind of digital ER-valve. In this work, a new model to describe the valve behavior is proposed and a comparison with the experimental results is presented. The experimental results show that the damping constant is able to be varied by changing the excitation pattern of the valve. Additionally, the comparison with the model shows that the measurement results and the model are in agreement. It proves that the new model is able to describe the behavior of such digital valve better compared to the existing model.

20 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JGJanusz Goldasz
Janusz Goldasz
BSBogdan Sapiński
Bogdan Sapiński
Michal KubíkMichal Kubík
Michal Kubík
OMOndřej Macháček
Ondřej Macháček
WBWojciech Bańkosz
Wojciech Bańkosz
ATAditya Suryadi Tan
Aditya Suryadi Tan
Magnetorheological (MR) actuators are semi-active devices controlled by magnetic stimuli. The technology has been commercialized in the automotive industry or high-quality optical finishing applications. It harnesses the rheology of smart fluids to result in the unique application of the material. By a wide margin, the most common example of an MR actuator is a flow-mode single-tube housing with a control valve (electromagnet with a fixed-size air gap filled with the MR fluid) operating in a semi-active vibration control environment. The analysis of the prior art shows that the developed configurations of MR valves vary in size, complexity, the ability to generate adequate levels of pressure, and the interactions with the MR fluid’s rheology resulting in various performance envelopes. Moreover, miscellaneous testing procedures make a direct valve-to-valve comparison difficult. Therefore, in this paper we present a detailed and systematic review of MR control valves, provide classification criteria, highlight the operating principle, and then attempt to categorize the valves into groups sharing similarities in the design and performance envelope(s). Moreover, a simple performance metric based on the shear stress calculation is proposed, too, for evaluating the performance of particular valving prototypes. In the review, we discuss the key configurations, highlight their strengths and weaknesses and explore various opportunities for tuning their performance range. The review provides complementary information for the engineers and researchers with a keen interest in MR applications, in general. It is an organized and and critical study targeted at improvements in the categorization and description of MR devices.

30 September 2022 in Actuators
Verified
Journal Article
Open access
PDF file
KJKiran Jacob
Kiran Jacob
ATAditya Suryadi Tan
Aditya Suryadi Tan
TSThomas Sattel
Thomas Sattel
Manfred KohlManfred Kohl
Manfred Kohl
A hybrid damper concept is presented here using a combination of a Magnetorheological (MR) Fluid (MRF) and Shape Memory Alloy (SMA)-based energy dissipation. A demonstration is performed utilizing the shear operating mode of the MRF and the one-way effect of the SMA. The damping performance of different MRF-SMA configurations is investigated and the corresponding energy consumption is evaluated. We demonstrate that the operation of MRF and SMA dampers complement each other, compensating for each other’s weaknesses. In particular, the slow response from the MR damper is compensated by passive SMA damping using the pseudoplastic effect of martensite reorientation, which can dissipate a significant amount of shock energy at the beginning of the shock occurrence. The MR damper compensates for the incapability of the SMA to dampen subsequent vibrations as long as the magnetic field is applied. The presented hybrid SMA-MR damper demonstrates superior performance compared to individual dampers, allowing for up to five-fold reduction in energy consumption of the MR damper alone and thereby opening up the possibility of reducing the construction volume of the MR damper.

7 July 2023 in Fluids
Verified
Journal Article
Open access
PDF file
ATAditya Suryadi Tan
Aditya Suryadi Tan
TSThomas Sattel
Thomas Sattel
RSRichard Subianto
Richard Subianto
Magnetorheological (MR) dampers have a virtue over conventional dampers, where their damping properties can be adjusted using a magnetic field. However, MR dampers have been barely implemented in small vibratory systems, in which the modal mass and stiffness are relatively small. This is due to two major reasons, namely its high parasitic damping force and big moving mass. When such an MR damper is installed in a small vibratory system, the system‘s default damping ratio is increased and therefore its dynamic is reduced. Here, a new concept of an MR damper utilizing the porous medium and shear operating mode together with an external non-moving electromagnet is proposed. This combination results in an MR damper with a low parasitic damping force and a small moving mass. For comparison purposes, a benchmark MR damper with comparable geometry is constructed. The proposed MR damper possesses a passive friction force that is 8× smaller and OFF-state passive viscous damping that is 10–20× smaller than the benchmark MR damper. An investigation of the proposed MR damper performance in a test vibratory system shows almost no reduction of the system dynamic. Therefore, this proposed MR damper configuration can be suitable for applications in small vibratory systems.

8 September 2020 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
ZZZhiyong Zhang
Zhiyong Zhang
TSThomas Sattel
Thomas Sattel
ATAditya Suryadi Tan
Aditya Suryadi Tan
XRXiaoting Rui
Xiaoting Rui
SYShaopu Yang
Shaopu Yang
XLXuan Li
Xuan Li
It is traditionally considered that, due to the Hertzian contact force-deformation relationship, the stiffness of rolling bearings has stiffening characteristics, and gradually researchers find that the supporting characteristics of the system may stiffen, soften, and even coexist from them. The resonant hysteresis affects the stability and safety of the system, and its jumping effect can make an impact on the system. However, the ball bearing contains many nonlinearities such as the Hertzian contact between the rolling elements and raceways, bearing clearance, and time-varying compliances (VC), leading great difficulties to clarify the dynamical mechanism of resonant hysteresis of the system. With the aid of the harmonic balance and alternating frequency/time domain (HB-AFT) method and Floquet theory, this paper will investigate the hysteretic characteristics of the Hertzian contact resonances of a ball bearing system under VC excitations. Moreover, the linearized dynamic bearing stiffness of the system will be presented for assessing the locations of VC resonances, and the nonlinear characteristics of bearing stiffness will also be discussed in depth. Our analysis indicates that the system possesses many types of VC resonances such as the primary, internal, superharmonic, and even combination resonances, and the evolutions of these resonances are presented. Finally, the suppression of resonances and hysteresis of the system will be proposed by adjusting the bearing clearance.