Magnetorheological (MR) actuators are semi-active devices controlled by magnetic stimuli. The technology has been commercialized in the automotive industry or high-quality optical finishing applications. It harnesses the rheology of smart fluids to result in the unique application of the material. By a wide margin, the most common example of an MR actuator is a flow-mode single-tube housing with a control valve (electromagnet with a fixed-size air gap filled with the MR fluid) operating in a semi-active vibration control environment. The analysis of the prior art shows that the developed configurations of MR valves vary in size, complexity, the ability to generate adequate levels of pressure, and the interactions with the MR fluid’s rheology resulting in various performance envelopes. Moreover, miscellaneous testing procedures make a direct valve-to-valve comparison difficult. Therefore, in this paper we present a detailed and systematic review of MR control valves, provide classification criteria, highlight the operating principle, and then attempt to categorize the valves into groups sharing similarities in the design and performance envelope(s). Moreover, a simple performance metric based on the shear stress calculation is proposed, too, for evaluating the performance of particular valving prototypes. In the review, we discuss the key configurations, highlight their strengths and weaknesses and explore various opportunities for tuning their performance range. The review provides complementary information for the engineers and researchers with a keen interest in MR applications, in general. It is an organized and and critical study targeted at improvements in the categorization and description of MR devices.
Magnetorheological (MR) fluids are suspensions of micrometer-sized ferromagnetic particles in a carrier fluid, which react to magnetic fields. The fluids can be operated in several fundamental modes. Contrary to the other modes, the rheology and microstructure formation of the MR fluid in the gradient pinch mode have been studied to a far lesser extent. The magnetic field distribution in the flow channel is intentionally made non-uniform. It is hypothesized that the Venturi-like contraction is achieved via fluid property changes, leading to a unique behavior and the presence of a pseudo-orifice. The main goal is to investigate the presence of the Venturi-like contraction effect in the fluid by means of optical imaging and hydraulic measurements. To accomplish the goal, a unique test rig has been developed including a fluorescence microscope and MR valve prototype. The Venturi-like contraction hypothesis was confirmed. The results indicate that the effective flow channel size decreases by 92% at the maximum magnetic flux applied. This has a direct impact on the flow characteristics of the MR valve. The variation of the pressure–flow rate curve slope with magnetic field was demonstrated. The results provide valuable information for understanding the rheology and microstructure formation mechanism in MR fluids in the pinch mode.
Core-shell nanostructures are widely used in many fields, including medicine and the related areas. An example of such structures are nanogold-shelled Fe3O4 magnetic nanoparticles. Systems consisting of a magnetic core and a shell made from nanogold show unique optical and magnetic properties. Thus, it is essential to develop the methodology of their preparation. Here, we report the synthesis methodology of Fe3O4@Au developed so as to limit their agglomeration and increase their stability. For this purpose, the impact of the reaction environment was verified. The properties of the particles were characterized via UV-Vis spectrophotometry, dynamic light scattering (DLS), X-ray diffraction (XRD), and Scanning Electron Microscopy-Energy Dispersive X-ray analysis (SEM-EDS technique). Moreover, biological investigations, including determining the cytotoxicity of the particles towards murine fibroblasts and the pro-inflammatory activity were also performed. It was demonstrated that the application of an oil and water reaction environment leads to the preparation of the particles with lower polydispersity, whose agglomerates’ disintegration is 24 times faster than the disintegration of nanoparticle agglomerates formed as a result of the reaction performed in a water environment. Importantly, developed Fe3O4@Au nanoparticles showed no pro-inflammatory activity regardless of their concentration and the reaction environment applied during their synthesis and the viability of cell lines incubated for 24 h with the particle suspensions was at least 92.88%. Thus, the developed synthesis methodology of the particles as well as performed investigations confirmed a great application potential of developed materials for biomedical purposes.
Magnetorheological (MR) fluids are representatives of smart materials. They react to magnetic fields by developing a yield stress. The effect has been employed in real-world applications such as automotive chassis systems or optical finishing. By convention, MR devices can be operated in at least one of the fundamental modes: flow, shear, squeeze, gradient pinch of which the former has been the least studied and understood. In pinch mode, the material in the flow channel is exposed to non-uniform magnetic fields in the direction parallel to fluid flow. As a result, only the volume of MR fluid near the channel walls are energized to modify the particular material property (yield stress). The result is the channel’s effective diameter change. The behavior of the material in pinch mode is unique and unseen in the other controllable fluids. To study the material’s characteristics in the specific mode, the authors developed a novel circuit concept for energizing the material in an effort to achieve the ‘true-zero’ pinch mode magnetic behavior. Contrary to the existing pinch mode valve concepts, the concept valve allows to achieve zero magnetic flux density in the center of the flow channel regardless of the current level. To test the hypothesis a prototype valve was modeled, manufactured and tested across a range of external (flow rate, current/magnetic flux) stimuli. The obtained results yield sufficient evidence proven by results of magnetic simulations to support the underlying hypothesis. The experimental results illustrate the pinch mode type behaviour, i.e. the slope change in the pressure vs flow rate characteristics.