Francesca Milesi

Dr. Francesca Milesi


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FMFrancesca Milesi
Francesca Milesi
MGMarco Giacometti
Marco Giacometti
LCLorenzo Coppadoro
Lorenzo Coppadoro
GFGiorgio Ferrari
Giorgio Ferrari
GFGianfranco Beniamino Fiore
Gianfranco Beniamino Fiore
Riccardo BertaccoRiccardo Bertacco
Riccardo Bertacco
The development of innovative diagnostic tests is fundamental in the route towards malaria eradication. Here, we discuss the sorting capabilities of an innovative test for malaria which allows the quantitative and rapid detection of all malaria species. The physical concept of the test exploits the paramagnetic property of infected erythrocytes and hemozoin crystals, the magnetic fingerprints of malaria common to all species, which allows them to undergo a selective magnetophoretic separation driven by a magnetic field gradient in competition with gravity. Upon separation, corpuscles concentrate at the surface of a silicon microchip where interdigitated electrodes are placed in close proximity to magnetic concentrators. The impedance variation proportional to the amount of attracted particles is then measured. The capability of our test to perform the selective detection of infected erythrocytes and hemozoin crystals has been tested by means of capture experiments on treated bovine red blood cells, mimicking the behavior of malaria-infected ones, and suspensions of synthetic hemozoin crystals. Different configuration angles of the chip with respect to gravity force and different thicknesses of the microfluidic chamber containing the blood sample have been investigated experimentally and by multiphysics simulations. In the paper, we describe the optimum conditions leading to maximum sensitivity and specificity of the test.

25 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PBPiero Borga
Piero Borga
FMFrancesca Milesi
Francesca Milesi
NPNicola Peserico
Nicola Peserico
CGChiara Groppi
Chiara Groppi
Francesco DaminFrancesco Damin
Francesco Damin
Riccardo BertaccoRiccardo Bertacco
Riccardo Bertacco
Integrated optical biosensors are gaining increasing attention for their exploitation in lab-on-chip platforms. The standard detection method is based on the measurement of the shift of some optical quantity induced by the immobilization of target molecules at the surface of an integrated optical element upon biomolecular recognition. However, this requires the acquisition of said quantity over the whole hybridization process, which can take hours, during which any external perturbation (e.g., temperature and mechanical instability) can seriously affect the measurement and contribute to a sizeable percentage of invalid tests. Here, we present a different assay concept, named Opto-Magnetic biosensing, allowing us to optically measure off-line (i.e., post hybridization) tiny variations of the effective refractive index seen by microring resonators upon immobilization of magnetic nanoparticles labelling target molecules. Bound magnetic nanoparticles are driven in oscillation by an external AC magnetic field and the corresponding modulation of the microring transfer function, due to the effective refractive index dependence on the position of the particles above the ring, is recorded using a lock-in technique. For a model system of DNA biomolecular recognition we reached a lowest detected concentration on the order of 10 pm, and data analysis shows an expected effective refractive index variation limit of detection of 7.5×10−9 RIU, in a measurement time of just a few seconds.