Reliable packaging for implantable neural prosthetic devices in body fluids is a long-standing challenge for devices’ chronic applications. This work studied the stability of Parylene C (PA), SiO2, and Si3N4 packages and coating strategies on tungsten wires using accelerated, reactive aging tests in three solutions: pH 7.4 phosphate-buffered saline (PBS), PBS + 30 mM H2O2, and PBS + 150 mM H2O2. Different combinations of coating thicknesses and deposition methods were studied at various testing temperatures. Analysis of the preliminary data shows that the pinholes/defects, cracks, and interface delamination are the main attributes of metal erosion and degradation in reactive aging solutions. Failure at the interface of package and metal is the dominating factor in the wire samples with open tips.
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed “bridge+trench” structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
Towards a distributed neural interface, consisting of multiple miniaturized implants, for interfacing with large-scale neuronal ensembles over large brain areas, this paper presents a mm-sized free-floating wirelessly-powered implantable opto-electro stimulation (FF-WIOS2) device equipped with 16-ch optical and 4-ch electrical stimulation for reconfigurable neuromodulation. The FF-WIOS2 is wirelessly powered and controlled through a 3-coil inductive link at 60 MHz. The FF-WIOS2 receives stimulation parameters via on-off keying (OOK) while sending its rectified voltage information to an external headstage for closed-loop power control (CLPC) via load-shift-keying (LSK). The FF-WIOS2 system-on-chip (SoC), fabricated in a 0.35-µm standard CMOS process, employs switched-capacitor-based stimulation (SCS) architecture to provide large instantaneous current needed for surpassing the optical stimulation threshold. The SCS charger charges an off-chip capacitor up to 5 V at 37% efficiency. At the onset of stimulation, the capacitor delivers charge with peak current in 1.7–12 mA range to a micro-LED (µLED) array for optical stimulation or 100–700 μA range to a micro-electrode array (MEA) for biphasic electrical stimulation. Active and passive charge balancing circuits are activated in electrical stimulation mode to ensure stimulation safety. In vivo experiments conducted on three anesthetized rats verified the efficacy of the two stimulation mechanisms. The proposed FF-WIOS2 is potentially a reconfigurable tool for performing untethered neuromodulation.
This paper presents a thin-film, three-dimensional (3D) opto-electro array featuring four addressable microscale light-emitting diodes (LEDs) for surface cortex illumination and nine penetrating electrodes for simultaneous recording of light-evoked neural activities. Inspired by the origami concept, we have developed a meticulously designed "bridge+trench" structure that facilitates the transformation of the array from 2D to 3D while preventing damage to the thin film metal. Prior to device transformation, the shape and dimensions of the 2D array can be customized, enhancing its versatility for various applications. In addition, the arched base offers strong mechanical support to facilitate the direct insertion of the probe into tissue without any mechanical reinforcement. The array was encapsulated using polyimide and epoxy to ensure mechanical flexibility and biocompatibility of the device. The efficacy of the device was evaluated through comprehensive in vitro and in vivo characterization.
High-density microelectrode arrays (HDMEAs) have become increasingly important tools in neuroscience and biomedical engineering because of their high spatial and temporal resolution for recording and modulating electrical activity across diverse biological systems. Initially developed for in vitro studies of cultured cells, HDMEAs are now being applied to increasingly complex models, including organoids, animal systems, and even human neural systems. These advancements enable a deeper investigation of cellular interactions, network dynamics, and disease mechanisms, as well as providing novel therapeutic and diagnostic tools for neurological disorders. This review explores the evolution of HDMEAs, emphasizing recent innovations in their design, fabrication, and functionalization. We discuss their applications across cellular models, organoid systems, animal studies, and human electrophysiology, and highlight current challenges such as biocompatibility, long-term stability, scalability, and translational deployment. Finally, we outline future directions for advancing HDMEA technologies in both research and clinical settings.
Bistable liquid crystal (LC) shutters have attracted much interest due to their low energy consumption and fast response time. In this paper, we demonstrate an electrically tunable/switchable biostable LC light shutter in biological optics through a three–step easy–assembly, inexpensive, multi–channel shutter. The liquid crystal exhibits tunable transparency (100% to 10% compared to the initial light intensity) under different voltages (0 V to 90 V), indicating its tunable potential. By using biomedical images, the response time, resolution, and light intensity changes of the LC under different voltages in three common fluorescence wavelengths are displayed intuitively. Particularly, the shutter’s performance in tumor images under the near–infrared band shows its application potential in biomedical imaging fields.