Jad  Farah

Dr. Jad Farah


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2014 in Journal of Radiological Protection
Verified
Journal Article
Closed access
CKC Koukorava
C Koukorava
JFJad Farah
Jad Farah
LSL Struelens
L Struelens
ICI Clairand
I Clairand
LDL Donadille
L Donadille
PDP Dimitriou
P Dimitriou
Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that 'wrap around' glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient's skin and to the x-ray field. With the use of such shields, the Hp(10) values recorded at the collar, chest and waist level and the Hp(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.

1 May 2015 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JFJad Farah
Jad Farah
VMV. Mares
V. Mares
MRM. Romero‐Expósito
M. Romero‐Expósito
STS. Trinkl
S. Trinkl
CDC. Domingo
C. Domingo
RHR. M. Harrison
R. M. Harrison

14 July 2013 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JFJad Farah
Jad Farah
LSL. Struelens
L. Struelens
JDJ. Dabin
J. Dabin
CKC. Koukorava
C. Koukorava
LDL. Donadille
L. Donadille
ICI. Clairand
I. Clairand
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, Hp(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with Hp(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, Hp(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.

1 September 2016 in Physica Medica
Verified
Journal Article
Open access
SPS. Principi
S. Principi
JFJad Farah
Jad Farah
PFP. Ferrari
P. Ferrari
ECE. Carinou
E. Carinou
ICI. Clairand
I. Clairand
MGM. Ginjaume
M. Ginjaume
This paper aims to provide some practical recommendations to reduce eye lens dose for workers exposed to X-rays in interventional cardiology and radiology and also to propose an eye lens correction factor when lead glasses are used. Monte Carlo simulations are used to study the variation of eye lens exposure with operator position, height and body orientation with respect to the patient and the X-ray tube. The paper also looks into the efficiency of wraparound lead glasses using simulations. Computation results are compared with experimental measurements performed in Spanish hospitals using eye lens dosemeters as well as with data from available literature. Simulations showed that left eye exposure is generally higher than the right eye, when the operator stands on the right side of the patient. Operator height can induce a strong dose decrease by up to a factor of 2 for the left eye for 10-cm-taller operators. Body rotation of the operator away from the tube by 45°-60° reduces eye exposure by a factor of 2. The calculation-based correction factor of 0.3 for wraparound type lead glasses was found to agree reasonably well with experimental data. Simple precautions, such as the positioning of the image screen away from the X-ray source, lead to a significant reduction of the eye lens dose. Measurements and simulations performed in this work also show that a general eye lens correction factor of 0.5 can be used when lead glasses are worn regardless of operator position, height and body orientation.

15 November 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
DBDavid Broggio
David Broggio
JBJ Beurrier
J Beurrier
MBM Bremaud
M Bremaud
ADA Desbrée
A Desbrée
JFJad Farah
Jad Farah
DFD Franck
D Franck
In order to best cover the possible extent of heights and weights of male adults the construction of 25 whole body 3D models has been undertaken. Such a library is thought to be useful to specify the uncertainties and relevance of dosimetry calculations carried out with models representing individuals of average body heights and weights. Representative 3D models of Caucasian body types are selected in a commercial database according to their height and weight, and 3D models of the skeleton and internal organs are designed using another commercial dataset. A review of the literature enabled one to fix volume or mass target values for the skeleton, soft organs, skin and fat content of the selected individuals. The composition of the remainder tissue is fixed so that the weight of the voxel models equals the weight of the selected individuals. After mesh and NURBS modelling, volume adjustment of the selected body shapes and additional voxel-based work, 25 voxel models with 109 identified organs or tissue are obtained. Radiation transport calculations are carried out with some of the developed models to illustrate potential uses. The following points are discussed throughout this paper: - justification of the fixed or obtained models’ features regarding available and relevant literature data; - workflow and strategy for major modelling steps; - advantages and drawbacks of the obtained library as compared with other works. The construction hypotheses are explained and justified in detail since future calculation results obtained with this library will depend on them.

11 May 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
VMVladimir Mares
Vladimir Mares
MRMaite Romero-Expósito
Maite Romero-Expósito
JFJad Farah
Jad Farah
STSebastian Trinkl
Sebastian Trinkl
CDCarles Domingo
Carles Domingo
RHRoger M Harrison
Roger M Harrison
The purpose of this study is to characterize the stray neutron radiation field in scanning proton therapy considering a pediatric anthropomorphic phantom and a clinically-relevant beam condition. Using two extended-range Bonner sphere spectrometry systems (ERBSS), Working Group 9 of the European Radiation Dosimetry Group measured neutron spectra at ten different positions around a pediatric anthropomorphic phantom irradiated for a brain tumor with a scanning proton beam. This study compares the different systems and unfolding codes as well as neutron spectra measured in similar conditions around a water tank phantom. The ten spectra measured with two ERBSS systems show a generally similar thermal component regardless of the position around the phantom while high energy neutrons (above 20 MeV) were only registered at positions near the beam axis (at 0°, 329° and 355°). Neutron spectra, fluence and ambient dose equivalent, H * (10), values of both systems were in good agreement (<15%) while the unfolding code proved to have a limited effect. The highest H * (10) value of 2.7 μ Sv Gy −1 was measured at 329° to the beam axis and 1.63 m from the isocenter where high-energy neutrons ( E ⩾ 20 MeV) contribute with about 53%. The neutron mapping within the gantry room showed that H * (10) values significantly decreased with distance and angular position with respect to the beam axis dropping to 0.52 μ Sv Gy −1 at 90° and 3.35 m. Spectra at angles of 45° and 135° with respect to the beam axis measured here with an anthropomorphic phantom showed a similar peak structure at the thermal, fast and high energy range as in the previous water-tank experiments. Meanwhile, at 90°, small differences at the high-energy range were observed. Using ERBSS systems, neutron spectra mapping was performed to characterize the exposure of scanning proton therapy patients. The ten measured spectra provide precise information about the exposure of healthy organs to thermal, epithermal, evaporation and intra-nuclear cascade neutrons. This comprehensive spectrometry analysis can also help in understanding the tremendous literature data based rem-counters while also being of great value for general neutron shielding and radiation safety studies.