Jérémie Dabin

Jérémie Dabin

Auto-generated profile, based on publicly available information

Jérémie Dabin

Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2023 in Nature Medicine
Verified
Journal Article
Open access
PDF file
MBMagda Bosch de Basea
Magda Bosch de Basea
ITIsabelle Thierry-Chef
Isabelle Thierry-Chef
RHRichard Harbron
Richard Harbron
MHMichael Hauptmann
Michael Hauptmann
GBGraham Byrnes
Graham Byrnes
ECElisabeth Cardis
Elisabeth Cardis
Over one million European children undergo computed tomography (CT) scans annually. Although moderate- to high-dose ionizing radiation exposure is an established risk factor for hematological malignancies, risks at CT examination dose levels remain uncertain. Here we followed up a multinational cohort (EPI-CT) of 948,174 individuals who underwent CT examinations before age 22 years in nine European countries. Radiation doses to the active bone marrow were estimated on the basis of body part scanned, patient characteristics, time period and inferred CT technical parameters. We found an association between cumulative dose and risk of all hematological malignancies, with an excess relative risk of 1.96 (95% confidence interval 1.10 to 3.12) per 100 mGy (790 cases). Similar estimates were obtained for lymphoid and myeloid malignancies. Results suggest that for every 10,000 children examined today (mean dose 8 mGy), 1–2 persons are expected to develop a hematological malignancy attributable to radiation exposure in the subsequent 12 years. Our results strengthen the body of evidence of increased cancer risk at low radiation doses and highlight the need for continued justification of pediatric CT examinations and optimization of doses.

13 March 2020 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
MCMaxime Chauvin
Maxime Chauvin
DBDamian Borys
Damian Borys
FBFrancesca Botta
Francesca Botta
PBPawel Bzowski
Pawel Bzowski
JDJeremie Dabin
Jeremie Dabin
MBManuel Bardiès
Manuel Bardiès
Background: Radiopharmaceutical dosimetry depends on the localization in space and time of radioactive sources and requires the estimation of the amount of energy emitted by the sources deposited within targets. In particular, when computing resources are not accessible, this task can be carried out using precomputed tables of Specific Absorbed Fractions (SAFs) or S values based on dosimetric models. The OpenDose collaboration aims to generate and make freely available a range of dosimetric data and tools. Methods: OpenDose brings together resources and expertise from 18 international teams to produce and compare traceable dosimetric data using 6 of the most popular Monte Carlo codes in radiation transport (EGSnrc/EGS++, FLUKA, GATE, Geant4, MCNP/MCNPX and PENELOPE). SAFs are uploaded, together with their associated statistical uncertainties, in a relational database. S values are then calculated from mono-energetic SAFs, based on the radioisotope decay data presented in the International Commission on Radiological Protection (ICRP) publication 107. Results: The OpenDose collaboration produced SAFs for all source regions and targets combinations of the two ICRP 110 adult reference models. SAFs computed from the different Monte Carlo codes were in good agreement at all energies, with standard deviations below individual statistical uncertainties. Calculated S values were in good agreement with OLINDA 2 (commercial) and IDAC 2.1 (free) software. A dedicated website (www.opendose.org) has been developed to provide easy and open access to all data. Conclusion: The OpenDose website allows the display and download of SAFs and the corresponding S values for 1252 radionuclides. The OpenDose collaboration, open to new research teams, will extend data production to other dosimetric models and implement new free features, such as online dosimetric tools and patient-specific absorbed dose calculation software, together with educational resources.

14 July 2013 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JFJad Farah
Jad Farah
LSL. Struelens
L. Struelens
JDJ. Dabin
J. Dabin
CKC. Koukorava
C. Koukorava
LDL. Donadille
L. Donadille
ICI. Clairand
I. Clairand
This paper presents the dosimetry part of the European ELDO project, funded by the DoReMi Network of Excellence, in which a method was developed to estimate cumulative eye lens doses for past practices based on personal dose equivalent values, Hp(10), measured above the lead apron at several positions at the collar, chest and waist levels. Measurement campaigns on anthropomorphic phantoms were carried out in typical interventional settings considering different tube projections and configurations, beam energies and filtration, operator positions and access routes and using both mono-tube and biplane X-ray systems. Measurements showed that eye lens dose correlates best with Hp(10) measured on the left side of the phantom at the level of the collar, although this correlation implicates high spreads (41 %). Nonetheless, for retrospective dose assessment, Hp(10) records are often the only option for eye dose estimates and the typically used chest left whole-body dose measurement remains useful.

26 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NBNathalie Berghen
Nathalie Berghen
KDKaat Dekoster
Kaat Dekoster
EMEyra Marien
Eyra Marien
JDJérémie Dabin
Jérémie Dabin
AHAmy Hillen
Amy Hillen
Greetje Vande VeldeGreetje Vande Velde
Greetje Vande Velde
Implementation of in vivo high-resolution micro-computed tomography (µCT), a powerful tool for longitudinal analysis of murine lung disease models, is hampered by the lack of data on cumulative low-dose radiation effects on the investigated disease models. We aimed to measure radiation doses and effects of repeated µCT scans, to establish cumulative radiation levels and scan protocols without relevant toxicity. Lung metastasis, inflammation and fibrosis models and healthy mice were weekly scanned over one-month with µCT using high-resolution respiratory-gated 4D and expiration-weighted 3D protocols, comparing 5-times weekly scanned animals with controls. Radiation dose was measured by ionization chamber, optical fiberradioluminescence probe and thermoluminescent detectors in a mouse phantom. Dose effects were evaluated by in vivo µCT and bioluminescence imaging read-outs, gold standard endpoint evaluation and blood cell counts. Weekly exposure to 4D µCT, dose of 540–699 mGy/scan, did not alter lung metastatic load nor affected healthy mice. We found a disease-independent decrease in circulating blood platelets and lymphocytes after repeated 4D µCT. This effect was eliminated by optimizing a 3D protocol, reducing dose to 180–233 mGy/scan while maintaining equally high-quality images. We established µCT safety limits and protocols for weekly repeated whole-body acquisitions with proven safety for the overall health status, lung, disease process and host responses under investigation, including the radiosensitive blood cell compartment.

30 July 2015 in Journal of Radiological Protection
Verified
Journal Article
Open access
MBMagda Bosch de Basea
Magda Bosch de Basea
MPMark S Pearce
Mark S Pearce
AKAusrele Kesminiene
Ausrele Kesminiene
MBMarie-Odile Bernier
Marie-Odile Bernier
JDJérémie Dabin
Jérémie Dabin
ECElisabeth Cardis
Elisabeth Cardis
Computed tomography (CT) has great clinical utility and its usage has increased dramatically over the years. Concerns have been raised, however, about health impacts of ionising radiation exposure from CTs, particularly in children, who have a higher risk for some radiation induced diseases. Direct estimation of the health impact of these exposures is needed, but the conduct of epidemiological studies of paediatric CT populations poses a number of challenges which, if not addressed, could invalidate the results. The aim of the present paper is to review the main challenges of a study on the health impact of paediatric CTs and how the protocol of the European collaborative study EPI-CT, coordinated by the International Agency for Research on Cancer (IARC), is designed to address them. The study, based on a common protocol, is being conducted in Belgium, Denmark, France, Germany, the Netherlands, Norway, Spain, Sweden and the United Kingdom and it has recruited over one million patients suitable for long-term prospective follow-up. Cohort accrual relies on records of participating hospital radiology departments. Basic demographic information and technical data on the CT procedure needed to estimate organ doses are being abstracted and passive follow-up is being conducted by linkage to population-based cancer and mortality registries. The main issues which may affect the validity of study results include missing doses from other radiological procedures, missing CTs, confounding by CT indication and socioeconomic status and dose reconstruction. Sub-studies are underway to evaluate their potential impact. By focusing on the issues which challenge the validity of risk estimates from CT exposures, EPI-CT will be able to address limitations of previous CT studies, thus providing reliable estimates of risk of solid tumours and leukaemia from paediatric CT exposures and scientific bases for the optimisation of paediatric CT protocols and patient protection.

1 October 2019 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
APAlessio Parisi
Alessio Parisi
JDJérémie Dabin
Jérémie Dabin
WSWerner Schoonjans
Werner Schoonjans
OHOlivier Van Hoey
Olivier Van Hoey
PMPatrice MEGRET
Patrice MEGRET
FVFilip Vanhavere
Filip Vanhavere