Kai Zhao

Dr. Kai Zhao


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2015 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
KZKai Zhao
Kai Zhao
GYGuozheng Yan
Guozheng Yan
LLLi Lu
Li Lu
FXFei Xu
Fei Xu

27 September 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
DHDing Han
Ding Han
GYGuozheng Yan
Guozheng Yan
ZWZhiwu Wang
Zhiwu Wang
PJPingping Jiang
Pingping Jiang
DLDasheng Liu
Dasheng Liu
JMJin Ma
Jin Ma
Intestinal-related diseases all around the world are increasing nowadays, and gradually become stubborn diseases threatening human health, and even lives. Diagnosis methods have attracted more and more attention. This article concerns a non-invasive way, a novel micro-robot, to diagnose intestinal diseases. This proposed micro-robot is a swallowable device, 14 mm in diameter, like a capsule. In order to make it possible for the micro-robot to move forward, backward, or anchor itself at a suspicious lesion point in the intestine with different lumen diameter sections, two key mechanisms have been proposed. One is an expanding mechanism with two-layer folded legs for anchoring. The designed expanding mechanism could realize a large variable diameter ratio, upwards of 3.43. In addition, a pair of specific annular gears instead of a traditional pinion drive is devised not only saving limited space, but also reducing energy loss. The other mechanism is a telescoping mechanism, possessing a self-locking lead screw nut system, which is used to obtain axial motion of the micro-robot. Then, the kinematics and dynamics of the micro-robot are analyzed. After that, the following experiments, including force tests and locomotion tests, are constructed. A good match is found between the theoretical results and the experimental data. Finally, in vitro experiments are performed with a prototype to verify the safety and reliability of the proposed micro-robot in porcine intestine.

29 March 2022 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
KZKai Zhao
Kai Zhao
HZHaoyu Zhuang
Haoyu Zhuang
LCLiu Cui
Liu Cui
JMJin Ma
Jin Ma
GYGuozheng Yan
Guozheng Yan
DHDing Han
Ding Han

12 June 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
KZKai Zhao
Kai Zhao
YYYu Yuan
Yu Yuan
KWKui Shuang Wang
Kui Shuang Wang
LCLiu Cui
Liu Cui
Parylene is widely used in the field of biomedical engineering due to its strong barrier properties against water and ions, as well as its superior biocompatibility. In this study, we have developed a pressure sensor module specifically for electronic capsules, where parylene is employed as the sealing material. The pressure sensors were packaged using parylene C and parylene N films with thicknesses of 15 μm, 30 μm, 45 μm, 60 μm, and 75 μm. The effect of parylene coating thickness on the performance of pressure sensors was investigated quantitatively by experiments. Various performance indicators such as sensitivity, linearity, root mean square error (RMSE), repeatability and dynamic response of the pressure sensors packaged with different parylene thicknesses have been thoroughly tested and analyzed. This research bears significance in informing the design of implantable pressure sensors.

7 March 2022 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
DHDing Han
Ding Han
GYGuozheng Yan
Guozheng Yan
SKShuai Kuang
Shuai Kuang
WWWei Wang
Wei Wang
KZKai Zhao
Kai Zhao

22 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LCLiu Cui
Liu Cui
KWKui Shuang Wang
Kui Shuang Wang
KZKai Zhao
Kai Zhao
ZSZhisen Si
Zhisen Si
In recent years, repackaging technology has been widely used in miniaturized implantable pressure sensors. However, the current packaging structure still has significant problems regarding biocompatibility, environmental adaptability, and measurement accuracy, which greatly limits its application in vivo measurement systems. In this paper, we report a method for implantable pressure sensor repackaging based on silicone oil, polydimethylsiloxane (PDMS) film, and polymer (parylene) coating. A systematic investigation using finite element analysis is conducted to assess the impact of packaging components on sensor performance, providing a solid theoretical foundation for packaging optimization. Experimental results demonstrate that when the parylene coating thickness is below 30 µm, the sensors exhibit superior linearity, repeatability, and reliability, along with exceptional stability and dynamic response across clinically relevant pressure ranges. This research provides valuable insights into the packaging design of implantable pressure sensors, facilitating the development of more stable, reliable, and cost-effective sensors for in vivo measurement systems.