The service life of adjacent box beam bridges is curtailed by the corrosion of reinforcement in the girders and spalling of concrete. This damage is attributed primarily to infiltration of water and chemical agents through longitudinal cracks in the shear keys. However, there are two other possible factors that can lead to water penetration of the bridge structure and eventual failure in box beam bridges: nonuniform box beam dimensions and bridge transverse slope. No study has been conducted to evaluate the effects of these two factors on induced stresses in adjacent box beam bridges. Typically, box girders are placed together with a transverse slope to facilitate drainage, which creates contact areas along just the bottom edges of adjacent girders. Additionally, for girders with nonuniform dimensions, even if within beam dimension tolerance, the contact between adjacent beams may be created at isolated spots. Measurements made at a box beam fabrication site verified inconsistency of beam dimensions. Three-dimensional finite-element models of composite and noncomposite single-span skew-adjacent box beam bridges were created to determine the stresses induce at the contact areas under environmental load conditions. The finite-element model was calibrated and validated in terms of the stresses in tie bars using experimental temperature profiles (uniform with and without temperature gradient). Two models were analyzed; the first model represented the contact areas generated due to drainage slope and the second one represented nonuniform beam dimensions using realistic input data. Under uniform and temperature gradient conditions, the models showed that contact stresses exceeded the concrete design strength at certain spots along the beams’ length. For girders with full flat contact, the contact stresses were noted to be less than the concrete strength. Additionally, the results of the analysis showed the contact stresses were reduced when modeling a bridge with a reinforced concrete deck. Moreover, the skew geometry showed a significant effect on the distribution of stresses at contact zones. Furthermore, the finite-element failure mode was compared with past research in terms of the locations of the greatest deterioration, and good agreement was found. Based on the results, it is recommended in this study to construct box beam bridges with enough spacing between the beams to ensure that no contact occurs between them; it is also recommended to manufacture box beams with high levels of accuracy.
1 June 2019 in Journal of Performance of Constructed Facilities
Adjacent box beams are widely used in bridge construction because they offer advantages of economy, ease of construction, durability, and appearance. Recently, a skewed deeper box beam section with a large number of strands has been developed. The geometry and amount of pre-stressed tension appear to lead to cracking at the end of box beam in a consistent pattern. The cracking may affect the durability of the bridge, particularly if corrosive materials can seep into the members and affect the pre-stressed strands and transverse tie rods. Some cracked beams were removed from a structure to a manufacturer’s storage yard where these cracks were examined in detail. This study investigates possible causes of these cracks, such as load effects created by pre-stressed tension. A 3-D finite element analysis was performed which incorporated nonlinear concrete material properties. The FEA modeled a box beam from Dry Creek Road Bridge with dimensions 1.22 m (48 in.) width, 0.84 m (33 in.) depth, and 28° skew angle, which had experiences cracks at the end. The tensile strains were modeled and the computed locations of the cracks matched well with those observed in the field. The results obtained from FE analysis were also compared with closed-form solutions. The analytical results showed the skewed geometry is the main cause of the cracking. The strain resulting from the transfer of pre-stressed force in concrete along the transfer length had a favorable effect on concrete crack.
14 September 2021 in Journal of Testing and Evaluation
This study investigates the causes of early-age deck cracking for skewed composite adjacent box beam bridges with integral abutments. It hypothesizes that cracking is attributed to (1) asymmetric thermal movements in a skewed deck and (2) thermal restraints from an integral abutment design, as well as box beams and post-tensioned tie rods. To verify this hypothesis, a bridge in Ohio was instrumented for measuring temperature and strain. The field investigation aimed at observing thermal movements of the deck for about five days immediately after placing the concrete deck. No visible cracks were found after completing the deck and abutments; however, 10 months later, visible cracks were observed. These cracks were mainly observed near the edges of the deck where it adjoins with an abutment, as well as at acute corners. Also, it was observed that a temperature gradient of 8°C developed through the deck depth. The rotation and expansion (or contraction) from the temperature gradient are partially restrained by the presence of box beams and post-tensioned tie rods, resulting in the effective tensile strain at the bottom surface. It is concluded that the skewed deck geometry causes an asymmetric thermal expansion, contraction, or both, leading to increased tensile strains. They exceeded the threshold cracking strain at the acute corner and at mid-width along the deck edges where they adjoin with asphalt roadways. It is also concluded that thermal restraints applied after completing the bridge is another factor for cracking. They are imposed by design features, including soil backfills and asphalt pavements, which are inherent to integral abutment bridges.
1 December 2016 in Journal of Performance of Constructed Facilities
In April 2014, a large structural plate arch culvert collapsed in Licking County, Ohio. The structure’s demise appeared to be related to a slope failure experienced by the roadway embankment fill above the inlet section. Shortly after the incident, a team of researchers from Ohio University conducted a forensic investigation of the structure. The team collected forensic data by visiting the site, testing soil samples taken near the culvert, and reviewing any past relevant documents. The team then employed the traditional slope stability analysis method, the AASHTO LRFD method, an empirical method found during a literature search, and computer simulation methods to gain further understanding of the culvert failure. The results of these analyses pointed the cause of the culvert failure toward what was speculated based on the field observations.
Precast pre-stressed box beam bridges are extensively used in short and medium span bridge design throughout the United States. Recently, skewed geometry and heavy pre-stressed box beams were developed. Field inspection of such beams indicated most of them experience vertical and inclined cracks within end regions of the box beam. The range of crack widths was within the limit that is required to be repaired before being used in the bridge construction. The depth of cracks was found to be very close to the tie rods and beam’s reinforcement. Field observation also indicated that cracks were more intensive at the acute corner than the obtuse corner. The beams with cracks form a durability concern, especially when the water and chemical agents filtrate through the cracks and reach the tie rods and strands. Therefore, a three-dimensional nonlinear finite element model was developed to simulate the behavior of the box girders after releasing strands. Case study girders surveyed during site visits were used for modeling and validating finite elements. The beams were modeled with actual material properties, geometry, and strands cutting sequence. The finite element results were validated with measured data in terms of crack locations and upward deflection. Two of the most appropriate crack-controlling techniques found in the literature were evaluated with finite element analysis: modification of beam design and debonding strands. The results of this study showed the modified girder design technique significantly minimize cracks at the top of the end zones if two strands with full pre-stressing forces were added around the vertical centerline of the top flange. A 35% level of strands’ debonding technique appeared to be effective in minimizing the maximum tensile strain at the beam’s ends. Debonding exterior strands was more effective on reducing tensile strain than debonding interior strands. The box beam with two strands at the top flange is recommended for implementation by skewed box beam design.