1 February 2018 in Journal of Performance of Constructed Facilities
Using a mechanically stabilized earth (MSE) wall as a bridge abutment has become an attractive option to the traditional cast-in-place wall abutment. The use of an MSE wall abutment notably simplifies the design and construction of the bridge abutment, requires less site preparation, allows faster construction, and consequently leads to cost saving. The poor performance of an MSE wall may be related to construction conditions, the wall materials, and poor soil below the foundations. In this paper, the results of a large-scale inspection program are analyzed to identify the most frequent MSE wall problems, and a new inspection rating system procedure is proposed. This paper also presents a risk assessment method to determine the overall rating of the MSE wall after inspection and suggests a course of action. Finally, the paper presents recommendations for the design and construction methods to avoid future problems.
1 August 2018 in Journal of Performance of Constructed Facilities
Across the United States, a large number of corrugated steel pipes, installed three or four decades ago, are approaching the end of their useful service life. In many cases, these aging drainage structures are having significant degrees of metal loss over their inverts due to conveyance of abrasive surface water, which can be acidic in some regions. A metal culvert under Coopermill Road near Zanesville in Muskingum County, Ohio, was selected for replacement based on its advanced level of invert metal loss. Before its replacement, invert paving was done in the half of the culvert toward its outlet end. The other half toward the inlet end was left untreated. With the concrete fully cured, each half of the culvert was instrumented with strain gauges and string potentiometers. Each half was tested under an external load of up to 267 kN (60 kip) placed over the crown. The strains and deflections were measured from the sensors, and the corresponding stresses, thrusts, and bending moments were computed. Despite the highly deteriorated conditions, the culvert structure supported a load considerably larger than the legal limit of 80 kN (18 kip). The invert-paved section of the culvert responded to the load with smaller strains, deflections, and thrusts and moments. The stresses at the interface of the steel culvert and the poured concrete treatment were not very large.
1 November 2011 in Journal of Pipeline Systems Engineering and Practice
In 2002, the Ohio Research Institute for Transportation and the Environment completed one of the most comprehensive field studies ever undertaken on thermoplastic pipes, involving 18 instrumented test pipes in a variety of installation conditions and subjected to either 6.1-m (20-ft) or 12.2-m (40-ft) high soil cover loading for a prolonged period of time. The ORITE researchers will continue to monitor the field performance of the test pipes for up to five years beyond the end of construction. The field performance data obtained during the initial phase of the project were recently reevaluated. The extensive volume of the data was analyzed further to gain additional insights into the field performance of thermoplastic pipes subjected to relatively deep soil fill. Particular attention was paid to the circumferential shortening behavior of the pipes, which has been rarely monitored by previous researchers. This paper presents the findings made while reviewing their field data. On the basis of these latest f...
1 August 2011 in Journal of Performance of Constructed Facilities
One of the latest solutions available for storm-water storage purposes is the underground chamber structure. Recently, a research team at Ohio University conducted a series of field load tests on the underground chambers. Four chamber structures were placed side by side in an excavated area, backfilled with coarse granular soil, buried under a soil cover of 0.46 m (18 in.), instrumented with sensors, and subjected to a series of controlled live load tests at a field project site. The sensor readings and visual inspection results indicate that the chamber with the specified minimum soil cover had no problem in supporting a wheel load of 52.3 kN (11.8 kips) and an axle load of 109.0 kN (24.5 kips) in both the transverse and longitudinal directions. Maximum reduction in the rise dimension was only approximately 2.3% when the chambers were subjected to the live loads. The vertical soil pressure readings measured at the chamber crowns were within 15% of the values given by a live load spreading formula include...
1 June 2013 in Journal of Performance of Constructed Facilities
A research institute at Ohio University recently conducted a comprehensive study on highway culvert structures for the Ohio Department of Transportation. During the study, a number of thermoplastic pipe structures under Ohio’s highways were inspected and rated. One of the thermoplastic pipe structures was a 0.61-m-diameter (24-in.-diameter) corrugated high-density polyethylene (HDPE) pipe under State Route 145 in Noble County, Ohio. What was unique about this pipe structure was that it was the oldest thermoplastic pipe culvert in service in Ohio. The pipe was installed under a shallow cover in 1981. The Ohio University team visited the culvert site in 2004 and inspected the pipe structure thoroughly. It was inspected again in June 2010. Drainage water entering the culvert was acidic, indicating the influence of a nearby surface coal-mining operation. The pipe structure had moderate amounts of deflection under the roadway, but overall it appeared to be in satisfactory condition. In 2004, a short pi...
1 December 2016 in Journal of Performance of Constructed Facilities
In April 2014, a large structural plate arch culvert collapsed in Licking County, Ohio. The structure’s demise appeared to be related to a slope failure experienced by the roadway embankment fill above the inlet section. Shortly after the incident, a team of researchers from Ohio University conducted a forensic investigation of the structure. The team collected forensic data by visiting the site, testing soil samples taken near the culvert, and reviewing any past relevant documents. The team then employed the traditional slope stability analysis method, the AASHTO LRFD method, an empirical method found during a literature search, and computer simulation methods to gain further understanding of the culvert failure. The results of these analyses pointed the cause of the culvert failure toward what was speculated based on the field observations.