Maha Nour

Ms. Maha Nour

Advanced Sensors, Oil and Gas Network Integrity, Research and Development Center, Saudi Aramco
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2018 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
JNJoanna Nassar
Joanna Nassar
SKSherjeel M. Khan
Sherjeel M. Khan
DVDiego Rosas Villalva
Diego Rosas Villalva
Maha NourMaha Nour
Maha Nour
AAAmani Saleh Almuslem
Amani Saleh Almuslem
MHMuhammad Hussain
Muhammad Hussain
The microclimate surrounding a plant has major effect on its health and photosynthesis process, where certain plants struggle in suboptimal environmental conditions and unbalanced levels of humidity and temperature. The ability to remotely track and correlate the effect of local environmental conditions on the healthy growth of plants can have great impact for increasing survival rate of plants and augmenting agriculture output. This necessitates the widespread distribution of lightweight sensory devices on the surface of each plant. Using flexible and biocompatible materials coupled with a smart compact design for a low power and lightweight system, we develop widely deployed, autonomous, and compliant wearables for plants. The demonstrated wearables integrate temperature, humidity and strain sensors, and can be intimately deployed on the soft surface of any plant to remotely and continuously evaluate optimal growth settings. This is enabled through simultaneous detection of environmental conditions while quantitatively tracking the growth rate (viz. elongation). Finally, we establish a nature-inspired origami-assembled 3D-printed “PlantCopter”, used as a launching platform for our plant wearable to enable widespread microclimate monitoring in large fields.

14 July 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Maha NourMaha Nour
Maha Nour
MHMuhammad Hussain
Muhammad Hussain
The real-time monitoring of fluid properties in tubular systems, such as viscosity and flow rate, is essential for industries utilizing liquid mediums. Nowadays, most studies of the fluid characteristics are performed off-line using laboratory facilities that can provide accurate results, yet they do not match the demanded industrial pace. Off-line measurements are ineffective and time-consuming. The available real-time monitoring sensors for fluid properties are generally destructive methods that produce significant and persistent damage to the tubular systems during the installation process. Others use huge and bulky invasive instrument methods that generate considerable pressure reduction and energy loss in tubular systems. For these drawbacks, industries centered their attention on non-invasive and non-destructive testing (NDT) methodologies, which are installed on the outer tubular surface to avoid flow disturbance and desist shutting down systems for installations. Although these sensors showed excellent achievement for monitoring and inspecting pipe health conditions, the performance was not convincing for monitoring the properties of fluids. This review paper presents an overview of the real-time monitoring of fluid properties in tubular systems for industrial applications, particularly for pipe monitoring sensors, viscosity, and flow measurements. Additionally, the different available sensing mechanisms and their advantages, drawbacks, and potentials are discussed.

2 January 2018 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
RBRabab R. Bahabry
Rabab R. Bahabry
AKArwa Kutbee
Arwa Kutbee
SKSherjeel M. Khan
Sherjeel M. Khan
ASAdrian C. Sepulveda
Adrian C. Sepulveda
IWIrmandy Wicaksono
Irmandy Wicaksono
MHMuhammad Hussain
Muhammad Hussain

20 November 2017 in Applied Physics Letters
Verified
Journal Article
Closed access
NQNadeem Qaiser
Nadeem Qaiser
SKS. M. Khan
S. M. Khan
Maha NourMaha Nour
Maha Nour
MRM. U. Rehman
M. U. Rehman
JRJ. P. Rojas
J. P. Rojas
MHMuhammad Hussain
Muhammad Hussain
A spiral interconnect array is a commonly used architecture for stretchable electronics, which accommodates large deformations during stretching. Here, we show the effect of different geometrical morphologies on the deformation behavior of the spiral island network. We use numerical modeling to calculate the stresses and strains in the spiral interconnects under the prescribed displacement of 1000 μm. Our result shows that spiral arm elongation depends on the angular position of that particular spiral in the array. We also introduce the concept of a unit-cell, which fairly replicates the deformation mechanism for full complex hexagon, diamond, and square shaped arrays. The spiral interconnects which are axially connected between displaced and fixed islands attain higher stretchability and thus experience the maximum deformations. We perform tensile testing of 3D printed replica and find that experimental observations corroborate with theoretical study.

25 October 2020 in Engineering Reports
Verified
Journal Article
Open access
PDF file
Maha NourMaha Nour
Maha Nour
SKSherjeel M. Khan
Sherjeel M. Khan
NQNadeem Qaiser
Nadeem Qaiser
SBSaleh A. Bunaiyan
Saleh A. Bunaiyan
MHMuhammad Hussain
Muhammad Hussain
Real‐time monitoring of fluid viscosities in tubular systems is essential for industries transporting fluid media. The available real‐time viscometers for tubular systems have major drawbacks, such as using invasive methods with large pressure drops due to flow disturbances, destructive installation processes with permanent tube damage, and limited operability with laminar flows. Therefore, developing a viscometer to address the above‐mentioned concerns is required for industrial applications. In this study, a new application of a velocity‐dependent viscometer using a novel design for real‐time measurements with insignificant flow disruption is proposed. It involves a Poly (methyl‐methacrylate) microchannel bridge with a microfluidic flowmeter attached to a mechanically flexible Polydimethylsiloxane platform connected to the inner surface of the pipe, which can adapt to different pipe diameters and curvatures. Moreover, the proposed viscometer uses the pipe flow driving force to flow fluids into the microchannel for measurement without requiring a pumping system or any sample withdrawals. The results of the simulation analysis match the experimental results of the sensor performance. The sensor can measure different viscosities in the range of 4‐334 mPa s with a resolution higher than 2.7 mPa s. Finally, a stand‐alone system is integrated with the sensor for wireless data transmission.

1 August 2014
Verified
Conference Paper
Closed access
Maha NourMaha Nour
Maha Nour
MGMohamed Ghoneim
Mohamed Ghoneim
RDRavi Droopad
Ravi Droopad
MHMuhammad Hussain
Muhammad Hussain
Flexible electronics using gallium arsenide (GaAs) for nano-electronics with high electron mobility and optoelectronics with direct band gap are attractive for many applications. Here we describe a state-of-the-art CMOS compatible batch fabrication process of transforming traditional electronic circuitry into large-area flexible, semi-transparent platform. We show a simple release process for peeling off 200 nm of GaAs from 200 nm GaAs/300 nm AlAs stack on GaAs substrate using diluted hydrofluoric acid (HF). This process enables releasing a single top layer compared to peeling off all layers with small sizes at the same time. This is done utilizing a network of release holes which contributes to the better transparency (45 % at 724 nm wavelength) observed.