Dual-comb spectroscopy can provide broad spectral bandwidth and high spectral resolution in a short acquisition time, enabling time-resolved measurements. Specifically, spectroscopy in the mid-infrared wavelength range is of particular interest, since most of the molecules have their strongest rotational-vibrational transitions in this “fingerprint” region. Here we report time-resolved mid-infrared dual-comb spectroscopy, covering ~300 nm bandwidth around 3.3 μm with 6 GHz spectral resolution and 20 μs temporal resolution. As a demonstration, we study a CH4/He gas mixture in an electric discharge, while the discharge is modulated between dark and glow regimes. We simultaneously monitor the production of C2H6 and the vibrational excitation of CH4 molecules, observing the dynamics of both processes. This approach to broadband, high-resolution, and time-resolved mid-infrared spectroscopy provides a new tool for monitoring the kinetics of fast chemical reactions, with potential applications in various fields such as physical chemistry and plasma/combustion analysis.
We present a multi-species trace gas sensor based on a high-repetition-rate mid-infrared supercontinuum source, in combination with a 30 m multipass absorption cell, and a scanning grating spectrometer. The output of the spectrometer is demodulated by a digital lock-in amplifier, referenced to the repetition rate of the supercontinuum source. This improved the detection sensitivity of the system by a factor 5, as compared to direct baseband operation. The spectrometer provides a spectral coverage of 950 cm−1 (between 2.85-3.90 µm) with a resolution of 2.5 cm−1 in 100 ms. It can achieve noise equivalent detection limits in the order of 100 ppbv Hz−1/2 for various hydrocarbons, alcohols, and aldehydes.
Conventional mechanical Fourier Transform Spectrometers (FTS) can simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a good spectral and temporal resolution. Here, we present a mid-infrared dual-comb-based FTS in an asymmetric configuration, providing broadband absorption and dispersion spectra with a spectral resolution of 5 GHz (0.18 nm at a wavelength of 3333 nm), a temporal resolution of 20 μs, a total wavelength coverage over 300 cm−1 and a total measurement time of ~70 s. We used the dual-comb spectrometer to monitor the reaction dynamics of methane and ethane in an electrical plasma discharge. We observed ethane/methane formation as a recombination reaction of hydrocarbon radicals in the discharge in various static and dynamic conditions. The results demonstrate a new analytical approach for measuring fast molecular absorption and dispersion changes and monitoring the fast dynamics of chemical reactions over a broad wavelength range, which can be interesting for chemical kinetic research, particularly for the combustion and plasma analysis community.
We demonstrate an absolute-frequency-calibrated mid-infrared dual-comb spectrometer by using a reference absorption cell. The source is based on a singly-resonant OPO containing two MgO:PPLN crystals in a common ring cavity, synchronously pumped by two mode-locked Yb-fiber lasers. The repetition-rate of the two pumps are stabilized while their offset frequencies and the OPO cavity length are not actively controlled. The reference spectrum is used to correct the frequency fluctuations in the sample spectrum providing a high-quality averaged spectrum with spectral resolution of 6 GHz and calibration precision of 120 MHz, without adding any complexity to the experimental setup or signal processing.
We present mid-infrared trace gas sensing based on a supercontinuum source combined with direct absorption spectroscopy and sum-frequency upconversion, showing broadband detection with a 10-4 Hz-1/2 noise equivalent absorbance sensitivity.
Conventional mechanical Fourier Transform Spectrometers (FTS) are able to simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a good spectral and temporal resolution. Here, we present a mid-infrared dual-comb-based FTS in an asymmetric configuration, providing broadband absorption and dispersion spectra with a spectral resolution of 5 GHz, a temporal resolution of 20 μs, and a total measurement time of a few minutes. We used the dual-comb spectrometer to monitor the reaction dynamics of methane and ethane in an electrical plasma discharge. We observed ethane/methane formation as a recombination reaction of hydrocarbon radicals in the discharge in various static and dynamic conditions. The results demonstrate a new analytical approach for measuring fast molecular absorption and dispersion changes and monitoring fast dynamics of chemical reactions, which can be interesting for chemical kinetic research and particularly for the combustion and plasma analysis community.