Recent advancements of mid-infrared (MIR) supercontinuum light sources have opened up new possibilities in laser-based trace gas sensing. While the supercontinuum sources inherently support wide spectral coverage, the detection of broadband absorption signals with high speed and low cost is traditionally limited by the MIR detector arrays. In this work, we demonstrate that this limitation can be circumvented by upconverting the MIR signal into the near-infrared (NIR) region, where cost-effective silicon-based detector arrays can be utilized to measure broadband absorption. We also show that, by combining a MIR supercontinuum source with a MIR-to-NIR upconverter and an astigmatic multipass cell, fast detection (~20 ms) of ethane with sub-ppmv sensitivity can be achieved at room temperature. For multi-species detection, a least-square global fitting method is presented, showing a promising potential for applications such as environmental monitoring and biomedical research.
We present a fast-scanning Fourier transform spectrometer (FTS) in combination with high-repetition-rate mid-infrared supercontinuum sources, covering a wavelength range of 2–10.5 µm. We demonstrate the performance of the spectrometer for trace gas detection and compare various detection methods: baseband detection with a single photodetector, baseband balanced detection, and synchronous demodulation at the repetition rate of the supercontinuum source. The FTS uses off-the-shelf optical components and provides a minimum spectral resolution of 750 MHz. It achieves a noise equivalent absorption sensitivity of ∼10−6 cm−1 Hz−1/2 per spectral element, by using a 31.2 m multipass absorption cell.
We present a fully integrated and transportable multi-species trace gas sensor based on a mid-infrared (MIR) supercontinuum light source. The high brightness (surpassing synchrotron) and ultra-broad spectral bandwidth (2–4 μm) of this light source allows simultaneous detection of multiple broadband absorbing gas species. High sensitivity in the sub-ppmv level has been achieved by utilizing an astigmatic multipass cell. A grating-based spectrometer at a scanning rate of 20 Hz is developed employing a balanced detection scheme. A multi-component global fitting algorithm is implemented into a central LabVIEW program to perform real-time data analysis. The obtained concentration values are validated by the standard gas chromatography mass spectrometry (GC-MS) method. Field application of the sensor for quality control of stored fruits at a small scale is demonstrated, involving the detection of ethylene, ethanol, ethyl acetate, acetaldehyde, methanol, acetone, and water simultaneously. The sensor also shows promising potentials for other applications, such as environmental monitoring and biomedical research.
We present a multi-species trace gas sensor based on a high-repetition-rate mid-infrared supercontinuum source, in combination with a 30 m multipass absorption cell, and a scanning grating spectrometer. The output of the spectrometer is demodulated by a digital lock-in amplifier, referenced to the repetition rate of the supercontinuum source. This improved the detection sensitivity of the system by a factor 5, as compared to direct baseband operation. The spectrometer provides a spectral coverage of 950 cm−1 (between 2.85-3.90 µm) with a resolution of 2.5 cm−1 in 100 ms. It can achieve noise equivalent detection limits in the order of 100 ppbv Hz−1/2 for various hydrocarbons, alcohols, and aldehydes.
We present a multi-species trace gas sensor based on a fast, compact home-built Fourier transform spectrometer (FTS) combined with a broadband mid-infrared supercontinuum (SC) source. The spectrometer covers the spectral bandwidth of the SC source (2 - 4 µm) and provides a best spectral resolution of 1 GHz in 6 seconds. It has a detection sensitivity of a few hundred of ppbv Hz-1/2 for different gas species. We study the performance of the developed spectrometer in terms of precision, linearity, long-term stability, and multi-species detection. We use the spectrometer for measuring fruit-produced volatiles under different atmospheric conditions and compare the performance with a previously developed scanning grating-based spectrometer.
Conventional mechanical Fourier Transform Spectrometers (FTS) can simultaneously measure absorption and dispersion spectra of gas-phase samples. However, they usually need very long measurement times to achieve time-resolved spectra with a good spectral and temporal resolution. Here, we present a mid-infrared dual-comb-based FTS in an asymmetric configuration, providing broadband absorption and dispersion spectra with a spectral resolution of 5 GHz (0.18 nm at a wavelength of 3333 nm), a temporal resolution of 20 μs, a total wavelength coverage over 300 cm−1 and a total measurement time of ~70 s. We used the dual-comb spectrometer to monitor the reaction dynamics of methane and ethane in an electrical plasma discharge. We observed ethane/methane formation as a recombination reaction of hydrocarbon radicals in the discharge in various static and dynamic conditions. The results demonstrate a new analytical approach for measuring fast molecular absorption and dispersion changes and monitoring the fast dynamics of chemical reactions over a broad wavelength range, which can be interesting for chemical kinetic research, particularly for the combustion and plasma analysis community.