Strong parameter dependence and large current ripple are two shortcomings that obstruct the development of model predictive control for voltage source inverters (VSIs). To solve these problems, in this article,a double-vector model-free predictive control (MFPC) method for VSI with visualization analysis is proposed. First, the ultralocal model of the VSI is established and a full-order sliding model observer is designed to estimate the lumped disturbance. MFPC is achieved with enhanced parameter robustness. Then, a double-vector MFPC method is further proposed. By applying two vectors per control period, the current ripple is reduced significantly. A detailed visualization analysis method is proposed, which verifies the effectiveness of the proposed double-vector MFPC method in theory. Besides, the proposed visualization analysis method has the potential to be used to analyze the effectiveness of other types of multivector model predictive control method with different cost functions. Detailed comparative experimental studies verify the effectiveness of the proposed double-vector MFPC method.
1 June 2022 in IEEE Transactions on Industrial Electronics
Grid-voltage sensorless model predictive control (MPC) strategies for grid-tied inverters (GTIs) have been studied frequently in recent years. However, the effects of dc-offset are not well addressed, and the current ripples are quite large as only one voltage vector (VV) is applied per control period. To solve these problems, a dc-offset reduced grid-voltage sensorless MPC strategy for GTIs with a two-stage optimal VV searching method is proposed. First, a new grid-voltage observer is proposed to reduce the effects of dc-offset. Second, by analyzing the proposed observer, it is found that the introduced intermediate variable can be used to estimate the dc-offset contained in the sampled grid current. Thus, the effects of dc-offset on the current control can be compensated accordingly. Third, to reduce the current ripples, a new two-stage optimal VV searching method is proposed on the basis of a detailed theoretical analysis. The novelty of this method is that it searches the phase and amplitude of the optimal VV in two independent stages, which reduces the number of VV that required to be evaluated online obviously. Finally, comparative experimental studies verify the effectiveness of the proposed methods in this article.
In recent years, virtual synchronous generator (VSG) control algorithm has been widely studied in distributed grid-connected power inverters to deal with active and reactive power adjustment by simulating the operation principle of the actual synchronous generator. Nevertheless, once the current sensor fails, the grid-connected power inverter will lose its stability. To enhance the fault-tolerant operation ability of the grid-connected power inverter, a new inverter side current sensor-less model predictive control method based on sliding mode observer (SMO) is proposed. The stability of the SMO is analyzed by using the Lyapunov stability criterion. The gains of the SMO are then designed by analyzing their influences on the current and voltage observation based on the closed-loop transfer functions. Besides, to show the influences of the capacitance changes on the current observation, a detailed parameter sensitivity analysis is also carried out. Then, by using the estimated inductance current from the SMO, a current sensor-less model predictive control method is finally proposed. The main novelty of the proposed method is that both the output voltage of the inverter and the inverter side inductance are not required in the proposed SMO. So, the accuracy of current sensor-less control is improved. To verify the effectiveness of the proposed method, detailed experimental studies are carried out based on a Typhoon and PE-Expert 4 based experimental platform.
Recently, model predictive control (MPC) methods have been widely used to achieve the control of two-level voltage source inverters due to their superiorities. However, only one of the eight basic voltage vectors is applied in every control cycle in the conventional MPC system, resulting in large current ripples and distortions. To address this issue, a dual-vector modulated MPC method is presented, where two voltage vectors are selected and utilized to control the voltage source inverter in every control cycle. The duty cycle of each voltage vector is figured out according to the hypothesis that it is inversely proportional to the square root of its corresponding cost function value, which is the first contribution of this paper. The effectiveness of this assumption is verified for the first time by a detailed theoretical analysis shown in this paper based on the geometrical relationship of the voltage vectors, which is another contribution of this paper. Moreover, further theoretical analysis shows that the proposed dual-vector modulated MPC method can also be extended to control other types of inverters, such as three-phase four-switch inverters. Detailed experimental results validate the effectiveness of the presented strategy.
29 March 2023 in Archives of Electrical Engineering
The disadvantages of the conventional model predictive current control method for the grid-connected converter (GCC) with an inductance-capacitance-inductance (LCL) filter are a large amount of calculation and poor parameter robustness. Once parameters of the model are mismatched, the control accuracy of model predictive control (MPC) will be reduced, which will seriously affect the power quality of the GCC. The article intuitively analyzes the sensitivity of parameter mismatch on the current predictive control of the conventional LCL-filtered GCC. In order to solve these issues, a model-free predictive current control (MFPCC) method for the LCL-filtered GCC is proposed in this paper. The contribution of this work is that a novel current predictive robust controller for the LCL-filtered GCC is designed based on the principle of the ultra-local model of a single input single output system. The proposed control method does not require using any model parameters in the controller, which can effectively suppress the disturbances of the uncertain parameter variations. Compared with conventional MPC, the proposed MFPCC has smaller current total harmonic distortion (THD). When the filter parameters are mismatched, the control error of the proposed method is smaller. Finally, a comparative experimental study is carried out on the platform of Typhoon and PE-Expert4 to verify the superiority and effectiveness of the proposed MFPCC method for the LCL-filtered GCC.
The neutral point clamped (NPC) three-level grid-tied converter is the key equipment connecting renewable energy and power grids. The current sensor fault caused by harsh environment may lead to the split of renewable energy. The existing sensor fault-tolerant methods will reduce the modulation ratio index of the converter system. To ensure continuous operation of the converter system and improve the modulation index, a model predictive control method based on reconstructed current is proposed in this paper. According to the relationship between fault phase current and a voltage vector, the original voltage vector is combined and classified. To maintain the stable operation of the converter and improve the utilization rate of DC voltage, two kinds of fault phase current are reconstructed with DC current, normal phase current and predicted current, respectively. Based on reconstructed three-phase current, a current predictive control model is designed, and a model predictive control method is proposed. The proposed method selects the optimal voltage vector with the cost function and reduces time delay with the current reconstruction sector. The simulation and experimental results showthat the proposed strategy can keep the NPC converter running stably with one AC sensor, and the modulation index is increased from 57.7% to 100%.