1 November 2022 in IEEE Transactions on Power Electronics
A parameter tuning method is critical for inductive power transfer (IPT) systems because it ensures constant output and reduces reactive power. This is especially true for the double-sided LCC (DS- LCC ) compensated IPT system due to its high parameter tuning freedom. This article proposes a parameter tuning method for the DS- LCC compensated IPT system. By reconfiguring key resonant parameters, the load-independent constant voltage (CV) output and zero phase angle (ZPA) can be achieved without varying operating frequency. Based on this, two compensation factors for the primary and secondary compensation inductances are defined, and the performance of the IPT system under different compensation factors and the optimal matching criterion of these two factors are investigated in detail. By optimizing these two compensation factors, the overall system efficiency is improved over the entire power range without affecting the property of CV and ZPA. A 2-kW experimental prototype is built to validate the practicability of the proposed tuning method. The experimental results indicate that when the dc load varies from 13.4 to 134 Ω, ZPA can always be achieved, and the output voltage fluctuation is only 4.6 V. The peak efficiency reaches 92.14% at a 1.6-kW output power.
18 March 2025 in IEEE Transactions on Power Electronics
This article presents a novel fault diagnosis method for open-circuit faults of insulated gate bipolar transistors (IGBTs) and current sensor faults in three-phase sinusoidal pulsewidth modulation inverters. The proposed method facilitates the simultaneous diagnosis of multiple IGBT and current sensor faults. A combination of Park transform and fast Fourier transform (FFT) is employed to extract fault features. The Park transform converts three-phase current into two-phase current, thereby reducing the dimensionality of the data. The FFT integrates time-domain and frequency-domain analyses to enhance the representation of fault characteristics. Additionally, fault features are extracted from the samples post-FFT to minimize the data volume of individual sample input by the model. For fault diagnosis, a temporal convolutional neural network model incorporating stacked residual blocks is developed to train and evaluate potential faults and demonstrate the model's validity and accuracy. The results of online simulations and hardware-in-the-loop experiments indicate that the proposed method can identify and locate the IGBT and sensor faults within 32 ms, and the accuracy is 98.75%. This method achieves higher training and testing accuracy and faster training and testing speed, which is superior to the existing diagnosis technologies.
22 January 2021 in IEEE Access
In recent years, virtual synchronous generator (VSG) control algorithm has been widely studied in distributed grid-connected power inverters to deal with active and reactive power adjustment by simulating the operation principle of the actual synchronous generator. Nevertheless, once the current sensor fails, the grid-connected power inverter will lose its stability. To enhance the fault-tolerant operation ability of the grid-connected power inverter, a new inverter side current sensor-less model predictive control method based on sliding mode observer (SMO) is proposed. The stability of the SMO is analyzed by using the Lyapunov stability criterion. The gains of the SMO are then designed by analyzing their influences on the current and voltage observation based on the closed-loop transfer functions. Besides, to show the influences of the capacitance changes on the current observation, a detailed parameter sensitivity analysis is also carried out. Then, by using the estimated inductance current from the SMO, a current sensor-less model predictive control method is finally proposed. The main novelty of the proposed method is that both the output voltage of the inverter and the inverter side inductance are not required in the proposed SMO. So, the accuracy of current sensor-less control is improved. To verify the effectiveness of the proposed method, detailed experimental studies are carried out based on a Typhoon and PE-Expert 4 based experimental platform.
27 March 2020 in IEEE Transactions on Plasma Science
Synchronous induction coilgun (SICG) typically includes an array of drive coils and a conductive armature. The structure of the drive coil and armature can greatly affect the launching performance of SICG. The traditional drive coils and armatures have a cylinder-shaped structure for simplicity and ease of fabrication. In this article, a novel structural SICG with stepped drive coil and stepped armature (SA) is proposed and investigated. As a comparison, four structural SICGs are researched by static and transient simulations. The static simulation results show that the stepped drive coil makes the magnetic field larger and the center of the magnetic field moves backward toward the tail end. The transient simulation results indicate that the SA improves the eddy current distribution and the positive propulsion force and weakens the reverse electromagnetic force and the armature capture effect at the same time. As a result of integrating the above characteristics, the new structural SICG with stepped drive coil and SA makes the optimal trigger position of armature move backward by 7 mm and improves the muzzle velocity by 4.79% and the launch efficiency by 9.82%.
12 July 2019 in IEEE Transactions on Plasma Science
Synchronous induction coilgun (SICG) has attracted more and more attention due to its advantages of simple manufacturing and no physical contact between armature and barrel. The armature, as an important component of SICG, will directly affect the launch speed and energy conversion efficiency. According to the distribution characteristics of eddy current and electromagnetic force, a new structural armature is proposed in this paper. The proposed inner conical armature is characterized by the maximum thickness at the tail end and the minimum thickness at the front end, with a gradual decrease in the thickness along the axial direction. The simulation results reveal that the proposed armature not only increases the mutual inductance between the armature and the drive coil but also enhances the electromagnetic force and weakens the armature capture effect. The experimental results verify that, compared with a traditional armature weighing 56.5 g, the new structure armature weighing 58.0 g enables higher muzzle velocities using the same set of pulsed power supply and drive coil, providing higher efficiency.
22 November 2017 in IEEE Transactions on Applied Superconductivity
Based on two high-temperature superconducting pulsed power transformers (HTSPPT), a double-module pulse power supply is presented and the collaborative discharge of the two modules is discussed in this paper. Seven discharge modes are compared and four evaluation criterions are used to evaluate the output current of the seven discharge modes. Simulation results show that three modes are proved to be feasible and can output a large rectangular pulse current with high amplitude and wide pulse width while the other four modes are all proved to be unsatisfactory and not recommended. Relevant experiments on mode one and mode two are carried out and its results verify the accuracy and rationality of simulation analysis.