Sarah Burkart

Dr. Sarah Burkart

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2021 in Pediatric Obesity
Verified
Journal Article
Open access
PDF file
SBSarah Burkart
Sarah Burkart
HPHannah Parker
Hannah Parker
GWGlenn Weaver
Glenn Weaver
MBMichael W. Beets
Michael W. Beets
AJAlexis Jones
Alexis Jones
BABridget Armstrong
Bridget Armstrong
Summary: Background: COVID‐19 school closures pose a threat to children's wellbeing, but no COVID‐19‐related studies have assessed children's behaviours over multiple years .Objective: To examine children's obesogenic behaviours during spring and summer of the COVID‐19 pandemic compared to previous data collected from the same children during the same calendar period in the 2 years prior.Methods: Physical activity and sleep data were collected via Fitbit Charge‐2 in 231 children (7–12 years) over 6 weeks during spring and summer over 3 years. Parents reported their child's screen time and dietary intake via a survey on 2–3 random days/week.Results: Children's behaviours worsened at a greater rate following the pandemic onset compared to pre‐pandemic trends. During pandemic spring, sedentary behaviour increased (+79 min; 95% CI = 60.6, 97.1) and MVPA decreased (−10 min, 95% CI = −18.2, −1.1) compared to change in previous springs (2018–2019). Sleep timing shifted later (+124 min; 95% CI = 112.9, 135.5). Screen time (+97 min, 95% CI = 79.0, 115.4) and dietary intake increased (healthy: +0.3 foods, 95% CI = 0.2, 0.5; unhealthy: +1.2 foods, 95% CI = 1.0, 1.5). Similar patterns were observed during summer.Conclusions: Compared to pre‐pandemic measures, children's PA, sedentary behaviour, sleep, screen time, and diet were adversely altered during the COVID‐19 pandemic. This may ultimately exacerbate childhood obesity.

19 June 2020 in Journal of Sports Sciences
Verified
Journal Article
Closed access
YZYanan Zhang
Yanan Zhang
RWR. Glenn Weaver
R. Glenn Weaver
BABridget Armstrong
Bridget Armstrong
SBSarah Burkart
Sarah Burkart
SZShuxin Zhang
Shuxin Zhang
MBMichael W. Beets
Michael W. Beets
Heart rate (HR), when combined with accelerometry, can dramatically improve estimates of energy expenditure and sleep. Advancements in technology, via the development and introduction of small, low-cost photoplethysmography devices embedded within wrist-worn consumer wearables, have made the collection of heart rate (HR) under free-living conditions more feasible. This systematic review and meta-analysis compared the validity of wrist-worn HR estimates to a criterion measure of HR (electrocardiography ECG or chest strap). Searches of PubMed/Medline, Web of Science, EBSCOhost, PsycINFO, and EMBASE resulted in a total of 44 articles representing 738 effect sizes across 15 different brands. Multi-level random effects meta-analyses resulted in a small mean difference (beats per min, bpm) of −0.40 bpm (95 confidence interval (CI) −1.64 to 0.83) during sleep, −0.01 bpm (−0.02 to 0.00) during rest, −0.51 bpm (−1.60 to 0.58) during treadmill activities (walking to running), while the mean difference was larger during resistance training (−7.26 bpm, −10.46 to −4.07) and cycling (−4.55 bpm, −7.24 to −1.87). Mean difference increased by 3 bpm (2.5 to 3.5) per 10 bpm increase of HR for resistance training. Wrist-worn devices that measure HR demonstrate acceptable validity compared to a criterion measure of HR for most common activities.

1 April 2021 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
SBSarah Burkart
Sarah Burkart
MBMed Michael W. Beets
Med Michael W. Beets
BABridget Armstrong
Bridget Armstrong
EHEthan T. Hunt
Ethan T. Hunt
RDRoddrick Dugger
Roddrick Dugger
RWR. Glenn Weaver
R. Glenn Weaver
Study Objectives:To compare sleep parameters produced by the Fitbit Charge 3 (Fitbit) and Actigraph GT9X accelerometer (Actigraph) to polysomnography (PSG) in youth.Methods:Youth (n=56, age=9.2±3.3...

29 March 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JWJames W. White
James W. White
OFOlivia L. Finnegan
Olivia L. Finnegan
NTNick Tindall
Nick Tindall
SNSrihari Nelakuditi
Srihari Nelakuditi
DBDavid E. Brown
David E. Brown
GWGlenn Weaver
Glenn Weaver
The purpose of this study was to evaluate the reliability and validity of the raw accelerometry output from research-grade and consumer wearable devices compared to accelerations produced by a mechanical shaker table. Raw accelerometry data from a total of 40 devices (i.e., n = 10 ActiGraph wGT3X-BT, n = 10 Apple Watch Series 7, n = 10 Garmin Vivoactive 4S, and n = 10 Fitbit Sense) were compared to reference accelerations produced by an orbital shaker table at speeds ranging from 0.6 Hz (4.4 milligravity-mg) to 3.2 Hz (124.7mg). Two-way random effects absolute intraclass correlation coefficients (ICC) tested inter-device reliability. Pearson product moment, Lin’s concordance correlation coefficient (CCC), absolute error, mean bias, and equivalence testing were calculated to assess the validity between the raw estimates from the devices and the reference metric. Estimates from Apple, ActiGraph, Garmin, and Fitbit were reliable, with ICCs = 0.99, 0.97, 0.88, and 0.88, respectively. Estimates from ActiGraph, Apple, and Fitbit devices exhibited excellent concordance with the reference CCCs = 0.88, 0.83, and 0.85, respectively, while estimates from Garmin exhibited moderate concordance CCC = 0.59 based on the mean aggregation method. ActiGraph, Apple, and Fitbit produced similar absolute errors = 16.9mg, 21.6mg, and 22.0mg, respectively, while Garmin produced higher absolute error = 32.5mg compared to the reference. ActiGraph produced the lowest mean bias 0.0mg (95%CI = -40.0, 41.0). Equivalence testing revealed raw accelerometry data from all devices were not statistically significantly within the equivalence bounds of the shaker speed. Findings from this study provide evidence that raw accelerometry data from Apple, Garmin, and Fitbit devices can be used to reliably estimate movement; however, no estimates were statistically significantly equivalent to the reference. Future studies could explore device-agnostic and harmonization methods for estimating physical activity using the raw accelerometry signals from the consumer wearables studied herein.


25 March 2021 in Pediatric Obesity
Verified
Journal Article
Closed access
PDF file
GWGlenn Weaver
Glenn Weaver
EHEthan Hunt
Ethan Hunt
BABridget Armstrong
Bridget Armstrong
MBMichael W. Beets
Michael W. Beets
KBKeith Brazendale
Keith Brazendale
LRLayton Ressor‐Oyer
Layton Ressor‐Oyer