Tomasz Lipecki

Prof. Tomasz Lipecki

Department of Structural Mechanics, Faculty of Civil Engineering and Architecture, Lublin University of Technology
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2018 in Fire Technology
Verified
Journal Article
Closed access
PDF file
WWWojciech Węgrzyński
Wojciech Węgrzyński
TLTomasz Lipecki
Tomasz Lipecki

27 February 2020 in Archives of Civil and Mechanical Engineering
Verified
Journal Article
Open access
PDF file
TLTomasz Lipecki
Tomasz Lipecki
PJPaulina Jamińska-Gadomska
Paulina Jamińska-Gadomska
JBJarosław Bęc
Jarosław Bęc
EBEwa Błazik-Borowa
Ewa Błazik-Borowa
The main objective of the study was to estimate the mean horizontal wind action on a façade scaffolding on the basis of full-scale data. Measurements of climatic parameters were carried out for a number of façade scaffoldings (120 structures) located in Poland over a 30-month period. The measurement points were located on 2–3 deck levels of each structure and at 2–4 points placed in each level. The measurements were carried out 3–4 times during each day for 5 consecutive days. At each point, two components of wind speed were measured: first with the vane probe directed perpendicular to the façade and then parallel to the façade. Each measurement lasted 60 s, and the data were recorded every 1 s. On the basis of wind speeds, a procedure was suggested that enabled estimation of the static wind action on façade scaffoldings. The responses of structures to this action were computed via FEM simulations. The results were compared with those based on the approaches recommended by the wind and scaffolding codes. Initial analyses, illustrated by three scaffoldings without a protective cover, indicated large discrepancies between the approaches and the possibility of wind action, which is not considered in the codes.

2 February 2023 in Fire Safety Journal
Verified
Journal Article
Closed access
WWWojciech Węgrzyński
Wojciech Węgrzyński
GKGrzegorz Krajewski
Grzegorz Krajewski
GKGrzegorz Kimbar
Grzegorz Kimbar
TLTomasz Lipecki
Tomasz Lipecki

23 June 2018 in Fire Technology
Verified
Journal Article
Closed access
PDF file
WWWojciech Węgrzyński
Wojciech Węgrzyński
TLTomasz Lipecki
Tomasz Lipecki
GKGrzegorz Krajewski
Grzegorz Krajewski

2 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TLTomasz Lipecki
Tomasz Lipecki
PJPaulina Jamińska-Gadomska
Paulina Jamińska-Gadomska
ASAndrzej Sumorek
Andrzej Sumorek
A system designed for making field measurements of wind action on engineering structures is described. The system is composed of sonic anemometers, differential pressure sensors, a barometer, and a thermohygrometer. The focus of this study is to determine the indications of sonic anemometers; to accomplish this goal, wind tunnel tests were performed. The tests did not involve checking the accuracy of the devices themselves, but determining their indications under field measurement conditions where certain unavoidable errors resulting from their installation can appear. The anemometer measurement uncertainty with respect to wind speed and angle was determined. The devices were rotated in a horizontal plane and inclined against and with the mean wind speed direction in a wind tunnel. Different tunnel wind speeds were tested. The results indicate stable device readings at different horizontal plane positions at different wind speeds and a low sensitivity to changes in inclination against the inflow.

1 October 2021 in Journal of Building Engineering
Verified
Journal Article
Closed access
TLTomasz Lipecki
Tomasz Lipecki
PJPaulina Jamińska-Gadomska
Paulina Jamińska-Gadomska
EBEwa Błazik-Borowa
Ewa Błazik-Borowa