In Pakistan, data for household electricity consumption are available in the form of monthly electricity bills only, and, therefore, are not helpful in establishing appliance-wise consumption. Further, it does not help in establishing the relationship among the household electricity consumption and various driving factors. This study aimed to unlock the household electricity consumption in Pakistan by analyzing electricity bills and investigating the impact of various socioeconomic, demographic, and dwelling parameters and usage of different appliances. The methodology adopted in this study was survey-based data collection of the residential sector. For this purpose, data were collected from 523 dwellings through surveys and interviews in Mirpur city. The results of the data analysis revealed that the average household electricity consumption is 2469 kWh/year with an average family size of seven and an average floor area of 78.91 m2. Based on possession of various appliances, the households were categorized into four types and their consumption patterns were established and compared. Air Conditioned (AC) houses consume 44% more electricity compared to the non-AC houses, whereas an Uninterrupted Power Supply (UPS) consumes electricity equivalent to an AC. The research findings are useful for policy makers and building designers and are discussed in the conclusion section.
9 October 2023 in Energy Conversion and Management
Rapid urbanization, global warming and enhanced quality of life have significantly increased the demand of indoor thermal comfort and air conditioning systems are not a luxury anymore, but a necessity. In order to fulfil this need, it is imperative to develop affordable and environmentally friendly cooling solutions for buildings. In this work, the 3E performance (energetic, economic and environmental) of electrically driven water-cooled vapour compression systems and thermally (solar) driven vapour absorption cooling systems are evaluated and the parameters affecting the performance of solar-driven vapour absorption systems are investigated. The energy simulation software TRNSYS is used to simulate the performance of both systems in order to fulfil the cooling needs of an industrial manufacturing building for the typical climate conditions for Lahore, Pakistan. Primary energy saving, initial investment, operational cost, and carbon footprint indices are used to analyse the performance of both systems. In addition, a parametric code is written in Python and linked with TRNSYS to perform a parametric study to investigate the effects of various parameters such as solar field size, storage tank volume, optimum annual and monthly collector angles, and flow rate in the solar field on the solar-driven vapour absorption chiller performance. The results reveal that around 5% more energy can be absorbed per collector surface area by changing the solar tilt angle on a monthly basis compared to one fixed angle. The analysis shows that electrically driven vapour compression-based cooling systems have much higher running cost and are potentially hazardous for the environment but have lower capital costs. On the other hand, solar thermal systems have lower running costs and emissions but require further reductions in the capital costs or government subsidies to make them viable.
Rising temperatures, increase in population, and dense urban morphology have resulted in increased cooling energy demands. The conventional degree-days method to calculate cooling energy demand considers only the sensible heat load of air and neglects the latent component. This study aims to estimate the cooling degree days based on the heat index (by considering both the sensible and latent loads) for the current and future years (2050 and 2080). Further, the ventilation load index for each of these cities has been established to unlock the impact of ventilation on the building’s total energy consumption for current and future years. The results show that heat index-based degree days have a stronger relationship with the buildings’ cooling energy consumption and, therefore, can predict the cooling energy demand of buildings with 20% higher accuracy than conventional temperature-based degree days. Analysis shows that cooling degree-days and frequency of temperature above the comfort range continue to increase in Pakistan, highlighting increased degree-days in the range from 11.0 to 41.6% by 2050 and from 28.4 to 126.5% by 2080. Prompt actions are essential to enhance the resilience of Pakistan’s national grid to meet these future cooling energy demands.