Taehoon Kim

Dr. Taehoon Kim

Delft University of Technology
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2015 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
HLHyongmin Lee
Hyongmin Lee
JKJisung Kim
Jisung Kim
DHDongwoo Ha
Dongwoo Ha
TKTaehoon Kim
Taehoon Kim
SKSuhwan Kim
Suhwan Kim
This brief proposes an amplitude shift keying (ASK) demodulator that uses switched-capacitor differentiators to make it compliant with the very high bit rate amendment to the ISO/IEC 14443 standard for contactless smart card applications. These differentiators detect transitions in modulated ASK signals with a carrier frequency of 13.56 MHz at data rates up to 6.78 Mb/s. The demodulator has been implemented in 0.18 μm CMOS technology. The total power consumption is under 350 μW. Measured results confirm correct operation, and it is further shown that this differentiating scheme allows the modulation index to be reduced to 2.56%.

25 December 2018 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
TKTaehoon Kim
Taehoon Kim
SSSangmin Shin
Sangmin Shin
SKSuhwan Kim
Suhwan Kim
An 8-channel ultrasound receiver compatible with in-probe electronics for 3-D ultrasound imaging is proposed. It has eight analog front-ends for signal conditioning and a beamforming embedded SAR analog-to-digital converter (ADC) for performing both an 8-to-1 analog summation and its digitization in charge mode. By combining the 30-dB programmable gain of the analog front-ends with the 60-dB signal-to-noise ratio of the ADC, the 8-channel receiver achieves the DR of 80.2 dB. The delay is set in increments of 4.17 ns, up to a maximum of 292 ns. Implemented in a 0.18-μm CMOS process, a prototype occupies an active area of 0.525 mm 2 /channel and draws 23.25 mW/channel at a sampling frequency of 20 MHz.

1 September 2016
Verified
Conference Paper
Closed access
TKTaehoon Kim
Taehoon Kim
HYHan Yang
Han Yang
SSSangmin Shin
Sangmin Shin
HLHyongmin Lee
Hyongmin Lee
SKSuhwan Kim
Suhwan Kim
In recent studies of ultrasound imaging systems, successive approximation register (SAR) analog-to-digital converters (ADCs) are suggested as an alternative architecture for low-power ultrasound receiver integrated circuits. However, the sampling period of a high-speed SAR ADC is very short - less than a few nanoseconds. This results in the need of a very wide unity-gain bandwidth of the amplifier in the anti-aliasing filter (AAF), and it also causes more serious kick-back noise. In this paper, a single-channel analog front-end (AFE) with a RC filter for a high-speed SAR ADC is presented. The RC filter relaxes the bandwidth requirement of the amplifier in the AAF by 16% and reduces kick-back noise coming from the ADC input. The proposed AFE is fabricated in 0.18μm CMOS process. The design achieves 5.05nV/√Hz input-referred noise density and the voltage gain is controlled in the range of [-3.02, 30.6] dB in a linear-in-dB scale with 16 steps by a 4-bit digital code. Our AFE circuit consumes 30mA from a 1.8V supply.

1 August 2011
Verified
Conference Paper
Closed access
JWJong-Kwan Woo
Jong-Kwan Woo
TKTaehoon Kim
Taehoon Kim
HLHyongmin Lee
Hyongmin Lee
SKSunkwon Kim
Sunkwon Kim
HLHyunjoong Lee
Hyunjoong Lee
SKSuhwan Kim
Suhwan Kim
In this paper, we describe a cyclic ADC to adopt the comparator-based switched-capacitor (CBSC) technique, for the first time, so as to compensate for the technology scaling and reduce power consumption by eliminating the need for high gain opamps. A boosted preset voltage is also introduced to improve the conversion rate without consuming more power. The ADC operates at 2.5MS/s, and near the Nyquist-rate, a prototype has a signal-to-noise and distortion ratio (SNDR) of 55.99 dB and a spurious-free dynamic-range (SFDR) of 66.85 dB. The chip was fabricated in 0.18μm CMOS and it has an active area of 0.146mm 2 and consumes 0.74mW from a 1.8V supply.

29 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
TKTaehoon Kim
Taehoon Kim
FFFabian Fool
Fabian Fool
DSDjalma dos Santos
Djalma dos Santos
ZCZu-Yao Chang
Zu-Yao Chang
ENEmile Noothout
Emile Noothout
MMichiel Pertijs
Michiel Pertijs
This paper presents an ultrasound transceiver application-specific integrated circuit (ASIC) directly integrated with an array of 12 × 80 piezoelectric transducer elements to enable next-generation ultrasound probes for 3D carotid artery imaging. The ASIC, implemented in a 0.18 µm high-voltage Bipolar-CMOS-DMOS (HV BCD) process, adopted a programmable switch matrix that allowed selected transducer elements in each row to be connected to a transmit and receive channel of an imaging system. This made the probe operate like an electronically translatable linear array, allowing large-aperture matrix arrays to be interfaced with a manageable number of system channels. This paper presents a second-generation ASIC that employed an improved switch design to minimize clock feedthrough and charge-injection effects of high-voltage metal–oxide–semiconductor field-effect transistors (HV MOSFETs), which in the first-generation ASIC caused parasitic transmissions and associated imaging artifacts. The proposed switch controller, implemented with cascaded non-overlapping clock generators, generated control signals with improved timing to mitigate the effects of these non-idealities. Both simulation results and electrical measurements showed a 20 dB reduction of the switching artifacts. In addition, an acoustic pulse-echo measurement successfully demonstrated a 20 dB reduction of imaging artifacts.

14 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DSDjalma dos Santos
Djalma dos Santos
FFFabian Fool
Fabian Fool
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
MSMaysam Shabanimotlagh
Maysam Shabanimotlagh
ENEmile Noothout
Emile Noothout
NJNicolaas de jong
Nicolaas de jong
High frame rate three-dimensional (3D) ultrasound imaging would offer excellent possibilities for the accurate assessment of carotid artery diseases. This calls for a matrix transducer with a large aperture and a vast number of elements. Such a matrix transducer should be interfaced with an application-specific integrated circuit (ASIC) for channel reduction. However, the fabrication of such a transducer integrated with one very large ASIC is very challenging and expensive. In this study, we develop a prototype matrix transducer mounted on top of multiple identical ASICs in a tiled configuration. The matrix was designed to have 7680 piezoelectric elements with a pitch of 300 μm × 150 μm integrated with an array of 8 × 1 tiled ASICs. The performance of the prototype is characterized by a series of measurements. The transducer exhibits a uniform behavior with the majority of the elements working within the −6 dB sensitivity range. In transmit, the individual elements show a center frequency of 7.5 MHz, a −6 dB bandwidth of 45%, and a transmit efficiency of 30 Pa/V at 200 mm. In receive, the dynamic range is 81 dB, and the minimum detectable pressure is 60 Pa per element. To demonstrate the imaging capabilities, we acquired 3D images using a commercial wire phantom.