Moein Mozaffarzadeh

Mr. Moein Mozaffarzadeh

Delft University of Technology
orcid
PostDoctoral researcher in Medical Ultrasound Technologies, ...

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
AMAli Mahloojifar
Ali Mahloojifar
MOMahdi Orooji
Mahdi Orooji
SASaba Adabi
Saba Adabi
MNMohammadreza Nasiriavanaki
Mohammadreza Nasiriavanaki
Photoacoustic imaging (PAI) is an emerging medical imaging modality capable of providing high spatial resolution of Ultrasound (US) imaging and high contrast of optical imaging. Delay-and-Sum (DAS) is the most common beamforming algorithm in PAI. However, using DAS beamformer leads to low resolution images and considerable contribution of offaxis signals. A new paradigm namely Delay-Multiply-and-Sum (DMAS), which was originally used as a reconstruction algorithm in confocal microwave imaging, was introduced to overcome the challenges in DAS. DMAS was used in PAI systems and it was shown that this algorithm results in resolution improvement and sidelobe degrading. However, DMAS is still sensitive to high levels of noise, and resolution improvement is not satisfying. Here, we propose a novel algorithm based on DAS algebra inside DMAS formula expansion, Double Stage DMAS (DSDMAS), which improves the image resolution and levels of sidelobe, and is much less sensitive to high level of noise compared to DMAS. The performance of DS-DMAS algorithm is evaluated numerically and experimentally. The resulted images are evaluated qualitatively and quantitatively using established quality metrics including signal-to-noise ratio (SNR), full-widthhalf- maximum (FWHM) and contrast ratio (CR). It is shown that DS-DMAS outperforms DAS and DMAS at the expense of higher computational load. DS-DMAS reduces the lateral valley for about 15 dB and improves the SNR and FWHM better than 13% and 30%, respectively. Moreover, the levels of sidelobe are reduced for about 10 dB in comparison with those in DMAS.

6 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
AMAli Mahloojifar
Ali Mahloojifar
MOMahdi Orooji
Mahdi Orooji
KKKarl Kratkiewicz
Karl Kratkiewicz
SASaba Adabi
Saba Adabi
MNMohammadreza Nasiriavanaki
Mohammadreza Nasiriavanaki
The Journal of Biomedical Optics (JBO) publishes peer-reviewed papers on the use of novel optical systems and techniques for improved health care and biomedical research.

27 January 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
KKKarl Kratkiewicz
Karl Kratkiewicz
RMRayyan Manwar
Rayyan Manwar
YZYang Zhou
Yang Zhou
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
KAKamran Avanaki
Kamran Avanaki
Photoacoustic imaging (PAI) is an emerging functional and molecular imaging technology that has attracted much attention in the past decade. Recently, many researchers have used the vantage system from Verasonics for simultaneous ultrasound (US) and photoacoustic (PA) imaging. This was the motivation to write on the details of US/PA imaging system implementation and characterization using Verasonics platform. We have discussed the experimental considerations for linear array based PAI due to its popularity, simple setup, and high potential for clinical translatability. Specifically, we describe the strategies of US/PA imaging system setup, signal generation, amplification, data processing and study the system performance.

1 March 2018 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
MSMasume Sadeghi
Masume Sadeghi
AMAli Mahloojifar
Ali Mahloojifar
MOMahdi Orooji
Mahdi Orooji

14 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
YYYan Yan
Yan Yan
MMMohammad Mehrmohammadi
Mohammad Mehrmohammadi
BMBahador Makkiabadi
Bahador Makkiabadi
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound imaging and the contrast of optical imaging. For linear-array PAI, a beamformer can be used as the reconstruction algorithm. Delay-and-sum (DAS) is the most prevalent beamforming algorithm in PAI. However, using DAS beamformer leads to low-resolution images as well as high sidelobes due to nondesired contribution of off-axis signals. Coherence factor (CF) is a weighting method in which each pixel of the reconstructed image is weighted, based on the spatial spectrum of the aperture, to mainly improve the contrast. We demonstrate that the numerator of the formula of CF contains a DAS algebra and propose the use of a delay-multiply-and-sum beamformer instead of the available DAS on the numerator. The proposed weighting technique, modified CF (MCF), has been evaluated numerically and experimentally compared to CF. It was shown that MCF leads to lower sidelobes and better detectable targets. The quantitative results of the experiment (using wire targets) show that MCF leads to for about 45% and 40% improvement, in comparison with CF, in the terms of signal-to-noise ratio and full-width-half-maximum, respectively.

6 September 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KAKamran Avanaki
Kamran Avanaki
MZMohsin Zafar
Mohsin Zafar
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
AHAli Hariri
Ali Hariri
XHXiangzhi Huang
Xiangzhi Huang
KAKamran Avanaki
Kamran Avanaki
One of the major concerns in photoacoustic computed tomography (PACT) is obtaining a high-quality image using the minimum number of ultrasound transducers/view angles. This issue is of importance when a cost-effective PACT system is needed. On the other hand, analytical reconstruction algorithms such as back projection (BP) and time reversal, when a limited number of view angles is used, cause artifacts in the reconstructed image. Iterative algorithms provide a higher image quality, compared to BP, due to a model used for image reconstruction. The performance of the model can be further improved using the sparsity concept. In this paper, we propose using a novel sparse dictionary to capture important features of the photoacoustic signal and eliminate the artifacts while few transducers is used. Our dictionary is an optimum combination of Wavelet Transform (WT), Discrete Cosine Transform (DCT), and Total Variation (TV). We utilize two quality assessment metrics including peak signal-to-noise ratio and edge preservation index to quantitatively evaluate the reconstructed images. The results show that the proposed method can generate high-quality images having fewer artifacts and preserved edges, when fewer view angles are used for reconstruction in PACT.