Objective . The imaging photoplethysmography (IPPG), which is applied to heart rate measurement, is susceptible to interference caused by illumination variations during photography. To improve the accuracy, robustness, and real-time performance of IPPG, a new method combined with modified ensemble empirical mode decomposition (EEMD) and fast independent component analysis (FastICA) was proposed. Approach . On the modified EEMD, to reduce the error caused by the residual white noise of the algorithm, it was characterized by recurrently updating zero-mean white noise for ensemble averaging based on the standard deviation of the input signal. On the modified FastICA, its constructed nonlinear function was superseded by Huber’s approximation function to improve the robustness and running speed. Main results . Comparison experiments were conducted between the MAHNOB-HCI database and own collected data. In the hybrid natural light and computer screen light scenario, the mean absolute error (MAE) of heart rate amounted to 0.93 beats per minute and the correlation coefficient reached 0.85. In the experiments of MAHNOB-HCI database, the MAE amounted to 6.03 beats per minute and the correlation coefficient reached 0.75. Furthermore, the modified method decreased the running time by approximately ten times compared to the original algorithms. Significance . Various experimental results demonstrated that the proposed method significantly improves the accuracy, timeliness, and interference resistance.
We propose a novel strategy for optical trapping and sorting of micro-nano particles that does not involve the flow of the immersion medium. The method employs the size- and velocity-dependent response of suspended polystyrene particles to the optical sieve of a dynamic fringelike pattern generated by a spatial light modulator. We not only experimentally demonstrate the trapping and transport of polystyrene particles with 2 μm diameter, but also study the sorting of a polydisperse suspension of polystyrene beads with diameters of 0.8 and 2 μm. The results provide new insights into particle manipulation and separation, and reveal that there is still scope for sorting smaller particles based on dynamic optical sieve.
Dynamic light scattering is a standard technique of nano-particle sizing in colloid systems. However, it is difficult to measure the particle size accurately in the flowing dispersion, which is inevitable in many applications, such as on-line measurement. In this paper, we present that the wave vector of the scattered light, which is averaged to a constant in traditional technique, varies with time when the particles undergoing not only the random motion but also the directional movement. This variation results in an additional term of sinc function to the traditional intensity autocorrelation function of the scattered light, thus affect the final particle size determination, especially for large velocity of the directional movement. The experimental results agree well with our derivation. We believe this will facilitate the extension of the technique of the dynamic light scattering to a wider range of application, especially of the on-line measurement in the flowing dispersion.
In recent years, the gaze estimation system, as a new type of human-computer interaction technology, has received extensive attention. The gaze estimation model is one of the main research contents of the system. The quality of the model will directly affect the accuracy of the entire gaze estimation system. To achieve higher accuracy even with simple devices, this paper proposes an improved mapping equation model based on homography transformation. In the process of experiment, the model mainly uses the “Zhang Zhengyou calibration method” to obtain the internal and external parameters of the camera to correct the distortion of the camera, and uses the LM(Levenberg-Marquardt) algorithm to solve the unknown parameters contained in the mapping equation. After all the parameters of the equation are determined, the gaze point is calculated. Different comparative experiments are designed to verify the experimental accuracy and fitting effect of this mapping equation. The results show that the method can achieve high experimental accuracy, and the basic accuracy is kept within 0.6. The overall trend shows that the mapping method based on homography transformation has higher experimental accuracy, better fitting effect and stronger stability.
In this paper, we study the response properties of multi-photon of NbN superconductor nanowire in superconducting single photon detector (SSPD). We measure the NbN nanowire device's DC characteristics and detection probability for single and multi-photon light pulse signal at a temperature of 3.5 K. The measured results show that the superconducting transition current of superconductor nanowire decreases as light irradiation intensity increases. The photon number detected by SSPD is derived from the slope of detection probability versus light intensity. We find that the detected photon number increases as superconducting nanowire bias current decreases. Moreover, based on quantum optics and hotspot theory, we analyze the mechanism of the multi-photon response of superconducting nanowire semi-quantitatively. This result may be of benefit to understanding SSPD and developing the SSPD with the capability of resolving photon number.