Aortic-valve stenosis can be complicated by bleeding that is associated with acquired type 2A von Willebrand syndrome. However, the prevalence and cause of the hemostatic abnormality in aortic stenosis are unknown.
Introduction: Our purpose in conducting this study was to determine whether administration of high-dose tranexamic acid (TA) at the time of diagnosis of postpartum haemorrhage (PPH) could reduce blood loss. Methods: This was a randomised, controlled, multicentred, open-label trial. Women with PPH >800 mL following vaginal delivery were randomly assigned to receive TA (loading dose 4 g over 1 hour, then infusion of 1 g/hour over 6 hours) or not. In both groups, packed red blood cells (PRBCs) and colloids could be used according to French guidelines. The use of additional procoagulant treatments was permitted only in cases involving intractable bleeding. The primary objective was to assess the efficacy of TA in the reduction of blood loss in women with PPH, and the secondary objectives were the effect of TA on PPH duration, anaemia, transfusion and the need for invasive procedures. Results: A total of 144 women fully completed the protocol (72 in each group). Blood loss between enrolment and 6 hours later was significantly lower in the TA group than in the control group (median, 173 mL; first to third quartiles, 59 to 377) than in controls (221 mL; first to third quartiles 105 to 564) (P = 0.041). In the TA group, bleeding duration was shorter and progression to severe PPH and PRBC transfusion was less frequent than in controls (P < 0.03). Invasive procedures were performed in four women in the TA group and in seven controls (P = NS). PPH stopped after only uterotonics and PRBC transfusion in 93% of women in the TA group versus 79% of controls (P = 0.016). Mild, transient adverse manifestations occurred more often in the TA group than in the control group (P = 0.03). Conclusions: This study is the first to demonstrate that high-dose TA can reduce blood loss and maternal morbidity in women with PPH. Although the study was not adequately powered to address safety issues, the observed side effects were mild and transient. A larger international study is needed to investigate whether TA can decrease the need for invasive procedures and reduce maternal morbidity in women with PPH. Trial registration: Controlled Trials ISRCTN09968140.
1 June 2013 in Archives of Cardiovascular Diseases
Background—: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results—: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions—: Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.