24 July 2003 in New England Journal of Medicine
Aortic-valve stenosis can be complicated by bleeding that is associated with acquired type 2A von Willebrand syndrome. However, the prevalence and cause of the hemostatic abnormality in aortic stenosis are unknown.
1 April 2014 in Circulation
Background—: Significant postprocedural aortic regurgitation (AR) is observed in 10% to 20% of cases after transcatheter aortic valve replacement (TAVR). The prognostic value and the predictors of such a complication in balloon-expandable (BE) and self-expandable (SE) TAVR remain unclear. Methods and Results—: TAVR was performed in 3195 consecutive patients at 34 hospitals. Postprocedural transthoracic echocardiography was performed in 2769 (92%) patients of the eligible population, and these patients constituted the study group. Median follow-up was 306 days (Q1–Q3=178–490). BE and SE devices were implanted in 67.6% (n=1872) and 32.4% (n=897). Delivery was femoral (75.3%) or nonfemoral (24.7%). A postprocedural AR≥grade 2 was observed in 15.8% and was more frequent in SE (21.5%) than in BE-TAVR (13.0%, P =0.0001). Extensive multivariable analysis confirmed that the use of a SE device was one of the most powerful independent predictors of postprocedural AR≥grade 2. For BE-TAVR, 8 independent predictors of postprocedural AR≥grade 2 were identified including femoral delivery ( P =0.04), larger aortic annulus ( P =0.0004), and smaller prosthesis diameter ( P =0.0001). For SE-TAVR, 2 independent predictors were identified including femoral delivery( P =0.0001). Aortic annulus and prosthesis diameter were not predictors of postprocedural AR for SE-TAVR. A postprocedural AR≥grade 2, but not a postprocedural AR=grade 1, was a strong independent predictor of 1-year mortality for BE (hazard ratio=2.50; P =0.0001) and SE-TAVR (hazard ratio=2.11; P =0.0001). Although postprocedural AR≥grade 2 was well tolerated in patients with AR≥grade 2 at baseline (1-year mortality=7%), it was associated with a very high mortality in other subgroups: renal failure (43%), AR<grade 2 at baseline (31%), low transaortic gradient (35%), or nonfemoral delivery (45%). Conclusions—: Postprocedural AR≥grade 2 was observed in 15.8% of successful TAVR and was the strongest independent predictor of 1-year mortality. The use of the SE device was a powerful independent predictor of postprocedural AR≥grade 2.
15 March 2000 in European Heart Journal
Background Hypoxaemia resulting from a right-to-left shunt occurs in patients with atrial septal defects and high pulmonary vascular resistance, but
28 July 2016 in New England Journal of Medicine
Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.)
29 September 2017 in European Journal of Cardio-Thoracic Surgery
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports. Participating hospitals contributed surgical and cardiological pre-, peri- and long-term postoperative data of mechanical circulatory support implants to the registry. Data for all implants performed from 1 January 2011 to 31 December 2016 were analysed. Several auditing methods were used to monitor the quality of the data. Data could be provided for in-depth studies, and custom data could be provided at the request of clinicians and scientists. This report includes updates of patient characteristics, implant frequency, mortality rates and adverse events. Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (>17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66–71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0–70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation. Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.