Byong-Jo Yun

Dr. Byong-Jo Yun

Pusan National university, Busan South Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
TATaehwan Ahn
Taehwan Ahn
JKJinhoon Kang
Jinhoon Kang
BBByeonggeon Bae
Byeonggeon Bae
JJJae Jun Jeong
Jae Jun Jeong
BYByong-Jo Yun
Byong-Jo Yun

4 March 2019 in AIChE Journal
Verified
Journal Article
Closed access
PDF file
TKTaeho Kim
Taeho Kim
TATaehwan Ahn
Taehwan Ahn
BBByeonggeon Bae
Byeonggeon Bae
JJJae Jun Jeong
Jae Jun Jeong
BYByong-Jo Yun
Byong-Jo Yun
KKKyungdoo Kim
Kyungdoo Kim

6 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JBJinyeong Bak
Jinyeong Bak
HKHuiyung Kim
Huiyung Kim
JJJae-Jun Jeong
Jae-Jun Jeong
DEDongjin Euh
Dongjin Euh
BYByong-Jo Yun
Byong-Jo Yun
In a multidimensional two-phase flow analysis, bubble size significantly affects interfacial transfer terms such as mass, momentum, and energy. With regard to bubbly flow, the application of a simple correlation-type bubble size model presents certain advantages, including short calculation times and ease of usage. In this study, we propose a semi-theoretical correlation developed from a steady state bubble number density transport equation for predicting the distribution of local bubble size using a computational fluid dynamics (CFD) code. The coefficients of the new correlation were determined using the local bubble parameters obtained on the basis of three existing vertical air-water experiments. Finally, these were implemented in commercial CFD code and evaluated against experimental data, which showed that the proposed correlation exhibits good prediction capability for forced convective air-water bubbly flows under low pressure conditions.

25 April 2019 in Journal of Pressure Vessel Technology
Verified
Journal Article
Closed access
PDF file
JJJong Chull Jo
Jong Chull Jo
JJJae-Jun Jeong
Jae-Jun Jeong
BYByong-Jo Yun
Byong-Jo Yun
JKJongkap Kim
Jongkap Kim
A computational fluid dynamics (CFD) analysis was performed to investigate the hydraulic response of the flow field inside the pressurized water reactor (PWR) steam generator (SG) secondary side and the connected part of main feed water pipe to an abrupt main feed water line break (FWLB) accident. To realistically analyze the transient flow field situation, the flow field was assumed to be occupied initially by highly compressed subcooled water except that the upper part of the SG secondary side where steam occupied as in the practical case and the break was assumed to occur at the circumferential weld line between the feed water nozzle and the main feed water pipe. This would result in a subcooled water flashing flow from the SG through the short-broken pipe end to the surrounding atmosphere, which was numerically simulated in this study. Typical results of the prediction in terms of the fluid transient velocity and pressure were illustrated and discussed. To examine the physical validity of the present numerical simulation of the subcooled water flashing flow, the transient mass flow rates predicted in this study were compared with the other previous numerical predictions based on the subcooled water nonflashing (no phase change) flow or saturated water flashing flow assumptions and the prediction by a simple analysis method.

30 September 2015 in Journal of Energy Engineering
Verified
Journal Article
Closed access
SBSung Hwan Bae
Sung Hwan Bae
THTae Wook Ha
Tae Wook Ha
JJJae-Jun Jeong
Jae-Jun Jeong
BYByong-Jo Yun
Byong-Jo Yun
DJDong Wook Jerng
Dong Wook Jerng
HKHan Gon Kim
Han Gon Kim

12 November 2024 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
JBJinyeong Bak
Jinyeong Bak
MDManh Long Doan
Manh Long Doan
SPSeongbae Park
Seongbae Park
JJJae-Jun Jeong
Jae-Jun Jeong
BYByong-Jo Yun
Byong-Jo Yun