A large eddy simulation at the conditions of experiments by Vattenfall [ 1 OECD/NEA-Vattenfall T-Junction Benchmark Specifications, Final version, July, 2009. [Google Scholar] ] was performed in order to investigate the phenomenon of turbulent mixing affecting the thermal fatigue in a T-junction. In the present LES based on the dynamic Vreman model, mean velocity, turbulence intensity, and Reynolds shear stress profiles show good agreement with those measured in the Vattenfall experiment. With the present LES results verified, the characteristics of vortical structures in terms of turbulent mixing resulting in thermal fatigue was investigated. The energy spectra are shown to have a dominant frequency of around St = 0.5 agreeing with the value reported in experiments. On the other hand, the dominant frequency near the wall is different from that reported at the centerline (St ∼ 1), meaning that the thermal fatigue may not result from the wake structure, and is affected by the vortical structures existing near the wall. This result is consistent with one stated by Muramatsu [ 2 T. Muramatsu , Generation Possibilities of Lower Frequency Components in Fluid Temperature Fluctuations Related to Thermal Striping Phenomena, Transactions of the 17th International Conference on Structural Mechanics in Reactor Technology (SMiRT 17), Prague, Czech Republic, August 17–22, 2003 . [Google Scholar] ] that the frequency characteristics near the wall are closely associated with arched vortices. In addition, the present LES results are used to provide useful insights in predicting this kind of flow using RANS computations.
In a multidimensional two-phase flow analysis, bubble size significantly affects interfacial transfer terms such as mass, momentum, and energy. With regard to bubbly flow, the application of a simple correlation-type bubble size model presents certain advantages, including short calculation times and ease of usage. In this study, we propose a semi-theoretical correlation developed from a steady state bubble number density transport equation for predicting the distribution of local bubble size using a computational fluid dynamics (CFD) code. The coefficients of the new correlation were determined using the local bubble parameters obtained on the basis of three existing vertical air-water experiments. Finally, these were implemented in commercial CFD code and evaluated against experimental data, which showed that the proposed correlation exhibits good prediction capability for forced convective air-water bubbly flows under low pressure conditions.
24 January 2012 in Journal of Nuclear Science and Technology
For the analysis of transient two-phase flows in nuclear reactor components, a three-dimensional thermal hydraulics code, named CUPID, has been being developed. We simulated the downcomer boiling experiment (DOBO) experiment in two-dimensions using the CUPID code to evaluate its two-phase flow models and verify its applicability to the downcomer boiling analysis. The simulation result showed that it can reproduce the important characteristics of the downcomer boiling, such as a flow pattern change from a bubbly flow to churn and mist flows and a circulation of liquid accelerated by bubbles. The two-phase flow models that require further improvement were identified as well for an enhanced prediction of the downcomer boiling.
I. Helically coiled tube heat exchangers are widely used owing to their compact structure and higher heat transfer capability.[1] They also have fewer issues related to thermal expansion, which can...
25 April 2019 in Journal of Pressure Vessel Technology
A computational fluid dynamics (CFD) analysis was performed to investigate the hydraulic response of the flow field inside the pressurized water reactor (PWR) steam generator (SG) secondary side and the connected part of main feed water pipe to an abrupt main feed water line break (FWLB) accident. To realistically analyze the transient flow field situation, the flow field was assumed to be occupied initially by highly compressed subcooled water except that the upper part of the SG secondary side where steam occupied as in the practical case and the break was assumed to occur at the circumferential weld line between the feed water nozzle and the main feed water pipe. This would result in a subcooled water flashing flow from the SG through the short-broken pipe end to the surrounding atmosphere, which was numerically simulated in this study. Typical results of the prediction in terms of the fluid transient velocity and pressure were illustrated and discussed. To examine the physical validity of the present numerical simulation of the subcooled water flashing flow, the transient mass flow rates predicted in this study were compared with the other previous numerical predictions based on the subcooled water nonflashing (no phase change) flow or saturated water flashing flow assumptions and the prediction by a simple analysis method.