Oliver Grosser

Dr. Oliver Grosser

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
HLHugo Levillain
Hugo Levillain
OBOreste Bagni
Oreste Bagni
CDChristophe M. Deroose
Christophe M. Deroose
ADArnaud Dieudonné
Arnaud Dieudonné
SGSilvano Gnesin
Silvano Gnesin
PFPatrick Flamen
Patrick Flamen
Purpose: A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. Methods: A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%–79%, no agreement ≤ 49%). Results: Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100–120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). Conclusion: Practitioners are encouraged to work towards adoption of these recommendations.

6 May 2015 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
JRJulian Manuel Michael Rogasch
Julian Manuel Michael Rogasch
ISIngo G Steffen
Ingo G Steffen
FHFrank Hofheinz
Frank Hofheinz
OGOliver Grosser
Oliver Grosser
Christian FurthChristian Furth
Christian Furth
HAHolger Amthauer
Holger Amthauer
The maximum standardized uptake value (SUVmax) is a common clinical parameter for quantification in F18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT), but it is influenced by image reconstruction. The aim of this study was to analyze the association of SUVmax deviations related to point spread function (PSF) and time-of-flight (TOF) reconstruction with tumor-to-background ratios (TBR) in colorectal liver metastases (CRLM). Fifteen patients (f, 6; m, 9; median age, 59 years; range, 32 to 72 years) with 28 liver metastases were included retrospectively. FDG-PET/CT imaging (median activity, 237 MBq; range, 231 to 252 MBq; median uptake, 61 min; range, 55 to 67 min) was performed on a Siemens Biograph mCT 64 followed by image reconstruction using 3D-ordered subset expectation maximization (3D-OSEM) or 3D-OSEM with PSF modeling - both with and without TOF information. Differences in SUVmax were analyzed using the Friedman test and Wilcoxon test for paired non-parametric data. The correlation of inter-method differences with the lesions’ TBR was studied using Spearman’s rank correlation coefficient (rho). Differences between lesions with low (4.8) TBR were analyzed using the Mann-Whitney U test (TBR measured with 3D-OSEM; binarized by its median). There was a significant correlation of the lesions’ TBR with relative SUVmax differences related to PSF (PSF + TOF vs. 3D-OSEM + TOF, rho = 0.61; PSF vs. 3D-OSEM, rho = 0.52) or TOF (PSF + TOF vs. PSF, rho = −0.58; 3D-OSEM + TOF vs. 3D-OSEM, rho = −0.61). Accordingly, PSF algorithms only showed higher SUVmax than non-PSF algorithms in lesions with a high TBR (median differences at low/high TBR, +2.6%/+9.1% [PSF + TOF vs. 3D-OSEM + TOF]; +0.7%/+6.4% [PSF vs. 3D-OSEM]). TOF integration also led to higher SUVmax but mainly at low TBR (low/high TBR, +10.4%/+1.8% [PSF + TOF vs. PSF]; +8.6%/−0.1% [3D-OSEM + TOF vs. 3D-OSEM]). Both PSF and TOF reconstruction resulted in a substantial alteration of SUVmax in CRLM. TOF provided the highest SUVmax increase in low-contrast lesions while - vice versa - PSF showed the most relevant increase in high-contrast lesions. Thus, one should be aware that quantitative analyses of lesions with varying TBR, e.g., in radiotherapy or follow-up studies, may be mainly affected by either PSF or TOF reconstruction, respectively.

19 September 2014 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
JRJulian Manuel Michael Rogasch
Julian Manuel Michael Rogasch
FHFrank Hofheinz
Frank Hofheinz
ALAlexandr Lougovski
Alexandr Lougovski
Christian FurthChristian Furth
Christian Furth
JRJuri Ruf
Juri Ruf
ISIngo G Steffen
Ingo G Steffen
F18-fluorodeoxyglucose positron-emission tomography (FDG-PET) reconstruction algorithms can have substantial influence on quantitative image data used, e.g., for therapy planning or monitoring in oncology. We analyzed radial activity concentration profiles of differently reconstructed FDG-PET images to determine the influence of varying signal-to-background ratios (SBRs) on the respective spatial resolution, activity concentration distribution, and quantification (standardized uptake value [SUV], metabolic tumor volume [MTV]). Measurements were performed on a Siemens Biograph mCT 64 using a cylindrical phantom containing four spheres (diameter, 30 to 70 mm) filled with F18-FDG applying three SBRs (SBR1, 16:1; SBR2, 6:1; SBR3, 2:1). Images were reconstructed employing six algorithms (filtered backprojection [FBP], FBP + time-of-flight analysis [FBP + TOF], 3D-ordered subset expectation maximization [3D-OSEM], 3D-OSEM + TOF, point spread function [PSF], PSF + TOF). Spatial resolution was determined by fitting the convolution of the object geometry with a Gaussian point spread function to radial activity concentration profiles. MTV delineation was performed using fixed thresholds and semiautomatic background-adapted thresholding (ROVER, ABX, Radeberg, Germany). The pairwise Wilcoxon test revealed significantly higher spatial resolutions for PSF + TOF (up to 4.0 mm) compared to PSF, FBP, FBP + TOF, 3D-OSEM, and 3D-OSEM + TOF at all SBRs (each P < 0.05) with the highest differences for SBR1 decreasing to the lowest for SBR3. Edge elevations in radial activity profiles (Gibbs artifacts) were highest for PSF and PSF + TOF declining with decreasing SBR (PSF + TOF largest sphere; SBR1, 6.3%; SBR3, 2.7%). These artifacts induce substantial SUVmax overestimation compared to the reference SUV for PSF algorithms at SBR1 and SBR2 leading to substantial MTV underestimation in threshold-based segmentation. In contrast, both PSF algorithms provided the lowest deviation of SUVmean from reference SUV at SBR1 and SBR2. At high contrast, the PSF algorithms provided the highest spatial resolution and lowest SUVmean deviation from the reference SUV. In contrast, both algorithms showed the highest deviations in SUVmax and threshold-based MTV definition. At low contrast, all investigated reconstruction algorithms performed approximately equally. The use of PSF algorithms for quantitative PET data, e.g., for target volume definition or in serial PET studies, should be performed with caution - especially if comparing SUV of lesions with high and low contrasts.

2 June 2015 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
ODOliver Dobrindt
Oliver Dobrindt
HAHolger Amthauer
Holger Amthauer
AKAlexander Krueger
Alexander Krueger
JRJuri Ruf
Juri Ruf
HWHeiko Wissel
Heiko Wissel
CLChristoph H. Lohmann
Christoph H. Lohmann
The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses.

1 December 2014 in NeuroImage
Verified
Journal Article
Open access
AKAngela Kolodziej
Angela Kolodziej
MLMichael Lippert
Michael Lippert
FAFrank Angenstein
Frank Angenstein
JNJenni Neubert
Jenni Neubert
APAnnette Pethe
Annette Pethe
JGJürgen Goldschmidt
Jürgen Goldschmidt
Electrical and optogenetic methods for brain stimulation are widely used in rodents for manipulating behavior and analyzing functional connectivities in neuronal circuits. High-resolution in vivo imaging of the global, brain-wide, activation patterns induced by these stimulations has remained challenging, in particular in awake behaving mice. We here mapped brain activation patterns in awake, intracranially self-stimulating mice using a novel protocol for single-photon emission computed tomography (SPECT) imaging of regional cerebral blood flow (rCBF). Mice were implanted with either electrodes for electrical stimulation of the medial forebrain bundle (mfb-microstim) or with optical fibers for blue-light stimulation of channelrhodopsin-2 expressing neurons in the ventral tegmental area (vta-optostim). After training for self-stimulation by current or light application, respectively, mice were implanted with jugular vein catheters and intravenously injected with the flow tracer 99m-technetium hexamethylpropyleneamine oxime (99mTc-HMPAO) during seven to ten minutes of intracranial self-stimulation or ongoing behavior without stimulation. The 99mTc-brain distributions were mapped in anesthetized animals after stimulation using multipinhole SPECT. Upon self-stimulation rCBF strongly increased at the electrode tip in mfb-microstim mice. In vta-optostim mice peak activations were found outside the stimulation site. Partly overlapping brain-wide networks of activations and deactivations were found in both groups. When testing all self-stimulating mice against all controls highly significant activations were found in the rostromedial nucleus accumbens shell. SPECT-imaging of rCBF using intravenous tracer-injection during ongoing behavior is a new tool for imaging regional brain activation patterns in awake behaving rodents providing higher spatial and temporal resolutions than 18F-2-fluoro-2-dexoyglucose positron emission tomography.

9 February 2016 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
OGOliver Grosser
Oliver Grosser
JRJuri Ruf
Juri Ruf
DKDennis Kupitz
Dennis Kupitz
APAnnette Pethe
Annette Pethe
GUGerhard Ulrich
Gerhard Ulrich
HAHolger Amthauer
Holger Amthauer
Perfusion scintigraphy (PS) using technetium-99m (99mTc) labeled albumin-aggregates is a mandatory step before hepatic radioembolization (RE) with yttrium-90-labeled microspheres. Within the bounds of a prospective clinical trial, this sub-analysis assessed the intrahepatic and intrapulmonary stability of two albumin-compounds, 99mTc-MAA (macroaggregated serum albumin, MAA) and 99mTc-HSA (human serum albumin, HSA) after intra-arterial injection. Methods: In n = 24 patients (age: 64.6y: 46.2-82.2) with metastatic colorectal cancer (mCRC), PS-data of both tracers were analyzed (n = 12 patients each). Biodistribution (liver, lung) and liver-lung shunt (LLS) was assessed by sequential planar scintigraphy (1h, 5h and 24h post intra-hepatic/intra-arterial injection; p.i.) using the region of interest (ROI) technique. Data were corrected for radioactive decay. Results: Liver uptake of MAA decreased significantly from 1h (median particle uptake=70.0%) to 5h (45.5%, p<0.0001) and 24h (27.9%, p<0.0001), respectively. MAA-uptake in the lungs at first increased significantly from 1h (2.7%) to 5h (3.8%, P = 0.0007) and then decreased significantly from 5h to 24h (3.0%, P = 0.002). HSA-uptake in the liver decreased significantly from 1h (70.2%) to 5h (65.0%, P = 0.0002) and from 1h to 24h (46.6%, p<0.0001). There was no significant change in pulmonary HSA-uptake (1h p.i: 2.4%) between time-points (p≥0.2). Liver-lung shunt (LLS) at 1h p.i. was 3.9% (25th/75th percentiles= 3.3/5.0%; range= 2.4-9.8%) for MAA and 3.2% (2.8/4.1%; 2.0-5.8%) for HSA (P = 0.2). MAA-LLS increased significantly from 1h (median LLS=3.9%) to 5h (7.7%, P = 0.0005) and 24h p.i. (9.9%, p0.006). The estimated biologic half-lives of albumin particles were 7.9h/22.4h (bi-exponential fit, adj. R2 = 0.77) and 41.7h (mono-exponential fit, adj. R2 = 0.76) for MAA and HSA, respectively. Conclusion: In comparison to 99mTc-MAA, 99mTc-HSA-microspheres appear to be more resistant to degradation over time, allowing a reliable LLS-determination even at later time-points.