The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses.
Dose optimization in computed tomography (CT) is crucial, especially in CT fluoroscopy (fluoro-CT) used for real-time navigation, affecting both patient and operator safety. This study evaluated the impact of spectral X-ray filtering using a tin filter (Sn filter), and a method called partial-angle computed tomography (PACT), which involves segmentally switching off the X-ray tube current at the ambient dose rate at the interventional radiologist’s (IR) position. Measurements were taken at two body regions (upper body: head/neck; lower body: lower legs/feet) using a 120 kV X-ray tube voltage, 3 × 5.0 mm CT collimation, 0.5 s rotation speed, and X-ray tube currents of 43 Eff.mAs (without Sn filter) and 165 Eff.mAs (with Sn filter). The study found significant dose reductions in both body regions when using the Sn filter and PACT together. For instance, in the upper body region, the combination protocol reduced from 11.8 µSv/s to 6.1 µSv/s (p < 0.0001) compared to the protocol without using these features. Around 8% of the reduction (about 0.5 µSv/s) is attributed to the Sn filter (p = 0.0005). This approach demonstrates that using the Sn filter along with PACT effectively minimizes radiation exposure for the IR, particularly protecting areas like the head/neck, which can only be insufficiently covered by (standard) radiation protection material.