Supakit Rooppakhun

Dr. Supakit Rooppakhun

Mechanical Engineering, Institute of Engineering, Suranaree University of Technology, Nakhon Ratchasima, Thailand
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ARAtcharawan Rattanasak
Atcharawan Rattanasak
PUPeerapong Uthansakul
Peerapong Uthansakul
MUMonthippa Uthansakul
Monthippa Uthansakul
TJTalit Jumphoo
Talit Jumphoo
KPKhomdet Phapatanaburi
Khomdet Phapatanaburi
SRSupakit Rooppakhun
Supakit Rooppakhun
Those with disabilities who have lost their legs must use a prosthesis to walk. However, traditional prostheses have the disadvantage of being unable to move and support the human gait because there are no mechanisms or algorithms to control them. This makes it difficult for the wearer to walk. To overcome this problem, we developed an insole device with a wearable sensor for real-time gait phase detection based on the kNN (k-nearest neighbor) algorithm for prosthetic control. The kNN algorithm is used with the raw data obtained from the pressure sensors in the insole to predict seven walking phases, i.e., stand, heel strike, foot flat, midstance, heel off, toe-off, and swing. As a result, the predictive decision in each gait cycle to control the ankle movement of the transtibial prosthesis improves with each walk. The results in this study can provide 81.43% accuracy for gait phase detection, and can control the transtibial prosthetic effectively at the maximum walking speed of 6 km/h. Moreover, this insole device is small, lightweight and unaffected by the physical factors of the wearer.

25 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Chotchuang PhombutChotchuang Phombut
Chotchuang Phombut
SRSupakit Rooppakhun
Supakit Rooppakhun
BSBura Sindhupakorn
Bura Sindhupakorn
This study evaluates the distal femur morphology of the Thai population using a three-dimensional (3D) measurement method, measuring the distance between the triangular point of the femoral 3D model. The 3D model of 360 Thai femoral obtained from 180 volunteers (90 males, 90 females; range 20–50 years, average 32.8 years) was created using reverse engineering techniques from computed tomography imaging data. Using the 3D identified landmark method, the morphometric parameters evaluated included transepicondylar axis length (TEA), mediolateral length (ML), anteroposterior width (AP), medial anteroposterior width (MAP), lateral anteroposterior width (LAP), medial condyle width (MCW), lateral condyle width (LCW), intercondylar notch width (WIN), intercondylar notch depth (DIN), medial posterior condyle height (MPC), lateral posterior condyle height (LPC), femoral aspect ratio (ML/AP), lateral femoral aspect ratio (ML/LAP), and medial femoral aspect ratio (ML/MAP). The measured data were summarized for the analysis of an average value and standard deviation. Statistical analysis was performed using the independent samples t-test, unequal variances t-test, and linear regression. A p-value less than 0.05 (<0.05) was regarded as statistically significant and indicates strong evidence of the hypothesis. Additionally, the K-means clustering analysis of Thai distal femoral to the optimum size of the prosthesis with the correlation between ML length and AP width was performed. The results found that the morphometric parameters of the Thai male distal femur were significantly different and higher than those of Thai females, except for the ratio of ML/AP and ML/MAP. Comparatively, there was a significant difference between the specific size of Thai distal femur and that of the Korean population, which was also smaller than that for Caucasians. In addition, there was a mismatch between the distal femoral component sizing of knee prosthesis and what is available and commonly used in Thailand. At least six sizes of ML and/or AP should be recommended for the reasonable design of distal femoral prosthesis for covering the anatomy of Thais. These data are useful for predicting the morphometric parameters in forensic anthropology and provide basic data for the design of knee prostheses suitable for the Thai population.

1 January 2010
Verified
Journal Article
Closed access
SRSupakit Rooppakhun
Supakit Rooppakhun
PSPiyasin Surasith
Piyasin Surasith
NVNatapoom Vatanapatimakul
Natapoom Vatanapatimakul
YKYupaporn Kaewprom
Yupaporn Kaewprom
KSKriskrai Sitthiseripratip
Kriskrai Sitthiseripratip

1 January 2013 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
SRSupakit Rooppakhun
Supakit Rooppakhun
SBSarawut Bua-Ngam
Sarawut Bua-Ngam
In Thailand, according to the bus accident statistics referred to Department of Land Transport (DLT), the highest risk represents the frontal crash accidents. In case of frontal crashworthiness, the high- decker bus safety was referred to the regulation no.29 of United Nations Economic Commission for Europe (ECE-R29). In this study, the frontal impact analysis of the high-decker passenger bus structure based on ECE-R29 using Finite Element (FE) analysis was focused on. The energy absorption including to the total deformation of the frontal cabin were evaluated. Three-dimensional FE model of frontal bus structure with- and without- simple impact attenuator were created and analyzed using ANSYS/Explicit software. In accordance with the results, the average magnitude of kinetic energy in case of impact attenuator revealed the value lower than those without impact attenuator owing to absorb energy in the impact attenuator. In addition, the total deformation regarding to the safe zone of the frontal cabin in the case of with impact attenuator were lower than without impact attenuator as 75.8%. Therefore, the frontal impact attenuator should be recommended to a high-decker bus for the driver protection in the event of crash accident.

20 December 2021 in Journal of Experimental Orthopaedics
Verified
Journal Article
Open access
PDF file
CPChotchuang Phombut
Chotchuang Phombut
SRSupakit Rooppakhun
Supakit Rooppakhun
BSBura Sindhupakorn
Bura Sindhupakorn
Purpose: This study evaluates the morphology of the Thai proximal tibia based on three-dimensional (3D) models to design the tibial component.Methods: The 3D models of 480 tibias were created using reverse engineering techniques from computed tomography imaging data obtained from 240 volunteers (120 males, 120 females; range 20–50 years). Based on 3D measurements, a digital ruler was used to measure the distance between the triangular points of the models. The morphometric parameters consisted of mediolateral length (ML), anteroposterior width (AP), medial anteroposterior width (MAP), lateral anteroposterior width (LAP), central to a medial length (CM), central to a lateral length (CL), medial anterior radius (MAR), lateral anterior radius (LAR), and tibial aspect ratio (AR). An independent t-test was performed for gender differences, and K-means clustering was used to find the optimum sizes of the tibial component with a correlation between ML length and AP width in Thai people.Results: The average morphometric parameters of Thai proximal tibia, namely ML, AP, MAP, LAP, CM, and CL, were as follows: 72.52 ± 5.94 mm, 46.36 ± 3.84 mm, 49.22 ± 3.62 mm, 43.59 ± 4.05 mm, 14.29 ± 2.72 mm, and 15.28 ± 2.99 mm, respectively. The average of MAR, LAR, and AR was 24.43 ± 2.11 mm, 21.52 ± 2.00 mm, and 1.57 ± 0.08, respectively. All morphometric parameters in males were significantly higher than those of females. There was a difference between the Thai proximal tibia and other nationalities and a mismatch between the size of the commercial tibial component and the Thai knee. Using K-means clustering analysis, the recommended number of ML and AP is seven sizes for the practical design of tibial components to cover the Thai anatomy.Conclusion: The design of the tibial component should be recommended to cover the anatomy of the Thai population. These data provide essential information for the specific design of Thai knee prostheses.

6 December 2023 in Symmetry
Verified
Journal Article
Open access
PDF file
AAAtthaphon Ariyarit
Atthaphon Ariyarit
SRSupakit Rooppakhun
Supakit Rooppakhun
WPWorawat Puangchaum
Worawat Puangchaum
TPTharathep Phiboon
Tharathep Phiboon
An alloy wheel is generally a symmetrically shaped part integral to a vehicle because its weight and strength can improve driving performance. Therefore, alloy wheel design is essential, and a novel design method should be considered. Currently, the Multi-Additional Sampling Efficient Global Optimization (MAs-EGO) has been proposed and widely implemented in various fields of engineering design. This study employed a surrogate model to maximize Expected Hypervolume Improvement (EHVI) for multi-objectives by increasing multi-sampling per iteration to update a surrogate model and evaluate an optimal point for alloy wheel design. Latin Hypercube Sampling (LHS) was used to generate an initial design of an alloy wheel, including the thickness and width of the spoke wheel. The maximum principal stress according to the dynamic cornering fatigue simulation was then evaluated for risk of failure using Finite Element (FE) analysis. The objectives were to minimize both the principal stress and weight of the symmetric alloy wheel. The Kriging method was used to construct a surrogate model, including a Genetic Algorithm (GA), which was performed to maximize hypervolume improvement to explore the next additional sampling point, and that point was also an optimal point for the process when computation had converged. Finally, FE results were validated through a designed apparatus to confirm the numerical solution. The results exhibit thatMulti-Additional Sampling Efficient Global Optimization can achieve an optimal alloy shape. The maximum principal stress distribution occurs in the spoke area and exhibits a symmetrical pattern around the axis following the cyclic bending load. The optimal design point of the alloy wheel can reduce 20.181% and 3.176% of principal stress and weight, respectively, compared to the initial design. The experimental results are consistent trend in the same direction as FEA results.