High back-pressure technology is a promising method for the waste heat recovery of exhaust steams in combined heat and power systems. In this research, a 300 MW coal-fired subcritical combined heat and power system was selected as the reference system, and modeled in EBSILON professional. Then, energy-based and exergy-based performances of the high back-pressure system and traditional combined heat and power system were compared under full operating conditions. Moreover, a novel exergy-based evaluation method, which considers the energy level of the heating supply, was proposed and applied to evaluate the two systems. Results show that: In design conditions, both the heating capacity and power output of the high back-pressure system were higher than those of the extraction condensing system, which led to 17.67% and 33.21% increments of the gross thermal efficiency and generation efficiency, respectively. Compared with the extraction condensing system, the exergy efficiencies of the high back-pressure system were 7.04–8.21% higher. According to the novel exergy-based evaluation, the exergy efficiencies for the generation of the high back-pressure system and extraction condensing system were 46.48% and 41.22%, respectively. This paper provides references for the thermodynamic performance evaluation of the combined heat and power system.
Under the challenge of global energy transition, coal-fired cogeneration systems are undergoing a technical revolution towards enhanced efficiency, heating capacity, and flexibility. In this paper, four schemes using a steam ejector integrated into a cogeneration system are designed. Considering operational safety, integrated locations are selected at the front and back of high- and medium-pressure turbines. Subsequently, the thermodynamic and operational characteristics under both design and off-design conditions are analyzed based on a model built in EBSILON Professional. Finally, a sensitivity analysis of the heating process is conducted. The results show that the integration of steam ejectors can increase the waste heat recovery ratio of exhaust steam by 18.42–45.61% under design conditions. The largest waste heat recovery ratio is obtained in System 4, resulting in the power generation efficiency () and gross energy utilization efficiency () of 81.95% and 65.53%, respectively. Meanwhile, the steam ejector can expand the power-load regulation range of the cogeneration system, and System 4 has the lowest lower power limit among all the systems. The values of Systems 1–4 reach extreme values at different mixed steam pressures of the ejector. Increasing the pinch point temperature difference reduces the power load and of Systems 1–4. The results provide technical solutions for improving the heating capacity and efficient and flexible operation of cogeneration systems.
While the visible plume from a cooling tower is not a pollutant, it can affect the surrounding environment. Moreover, the accompanied evaporation loss has a great potential for wastewater recovery. In the present study, a novel coupling technology for water conservation and plume abatement was proposed, and its feasibility was verified by using thermodynamic analysis. A surface-type heat exchanger was designed and a thermodynamic calculation model was established. Next, based on the principle of “no plume,” the effect of the number of heat exchanger units (N) and the circulating water volume (G) on the water conservation and plume abatement was evaluated under design condition. Results showed that the optimized parameters for the operation of the cooling towers were N = 8 and G < 3000 m3/h, which have a good effect on water conservation and plume abatement. Furthermore, as per the condensation calculation model, the average water conservation amount was 1.105 kg/s and the annual water conservation amount reached 2.8641 × 107 kg.