Mustafa Merih Arıkan

Dr. Mustafa Merih Arıkan


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2001 in Wear
Verified
Journal Article
Closed access
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
HÇH Çimenoğlu
H Çimenoğlu
EKE.S Kayali
E.S Kayali

28 August 2015 in Metals
Verified
Journal Article
Open access
PDF file
AGAhmet Guner
Ahmet Guner
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
MNMehmet Nebioglu
Mehmet Nebioglu
Integral foam has been used in the production of polymer materials for a long time. Metal integral foam casting systems are obtained by transferring and adapting polymer injection technology. Metal integral foam produced by casting has a solid skin at the surface and a foam core. Producing near-net shape reduces production expenses. Insurance companies nowadays want the automotive industry to use metallic foam parts because of their higher impact energy absorption properties. In this paper, manufacturing processes of aluminum integral foam with casting methods will be discussed.

3 June 2015 in Metals
Verified
Journal Article
Open access
PDF file
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
Hot ductility properties of a peritectic steel for welded gas cylinders during continuous casting were studied by performing hot tensile tests at certain temperatures ranging from 1200 to 700 °C for some cooling rates by using Gleeble-3500 thermo-mechanical test and simulation machine in this study. The effects of cooling rate and strain rate on hot ductility were investigated and continuous casting process map (time-temperature-ductility) were plotted for this material. Reduction of area (RA) decreases and cracking susceptibility increases during cooling from solidification between certain temperatures depending on the cooling rate. Although the temperatures which fracture behavior change upon cooling during continuous casting may vary for different materials, it was found that the type of fracture was ductile at 1100 and 1050 °C; semi-ductile at 1000 °C, and brittle at 800 °C for the steel P245NB. There is a ductility trough between 1000 and 725 °C. The ductility trough gets slightly narrower as the cooling rate decreases.

27 December 2007 in Physical Review B
Verified
Journal Article
Closed access
PDF file
SDS. Demirtas
S. Demirtas
MHM. R. Hossu
M. R. Hossu
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
AKAli R. Koymen
Ali R. Koymen
MSM. B. Salamon
M. B. Salamon
Temperature dependent static magnetic properties of Co∕Gd multilayers, grown on SmCo, are experimentally investigated by means of SQUID magnetometry. The SmCo∕(Co∕Gd) system shows an exchange spring behavior above the compensation temperature (Tcomp) at which the magnetization of the antiferromagnetically coupled multilayer is zero. Below Tcomp, a tunable negative coercivity state (inverse hysteresis) appears, due to the coupling between the hard SmCo and soft Co∕Gd multilayers, irrespective of whether Co or Gd is proximate to the SmCo. However, for the strongly ferromagnetically coupled Co interface layer, negative coercivity persists over a larger temperature interval. The negative coercivity state vanishes if the coercivity of the SmCo layer is increased by controlling the Cu underlayer thickness.

6 March 2013 in Metallurgical and Materials Transactions B
Verified
Journal Article
Closed access
PDF file
SOSabri Ozturk
Sabri Ozturk
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
YKYilmaz Kacar
Yilmaz Kacar

29 March 2023 in Journal of Scientific Reports-A
Verified
Journal Article
Closed access
PDF file
GBGökhan Başman
Gökhan Başman
MAMustafa Merih Arıkan
Mustafa Merih Arıkan
CACevat Arisoy
Cevat Arisoy
KŞKelami Şeşen
Kelami Şeşen
Biomaterials are used in different parts of human body as replacement implants in medical applications. An implant material should have high biocompatibility, corrosion and wear resistance, and suitable mechanical properties in terms of safety and long-service period. There are only a few biocompatible implant materials: AISI316L stainless steel is one of the materials used in this type of applications. They have relatively poor wear resistance. Boriding being a thermochemical diffusion treatment is one of the processes to improve their wear resistance. Borides are formed by introducing boron atoms by diffusion onto a substrate surface and they are non-oxide ceramics and could be very brittle. The growth kinetics of boride layer is analyzed by measuring depth of layers as a function of boriding time within a temperature range. In this study, the effects of Ekabor-2 bath on formation mechanism and properties of boride layer in thermochemical diffusion boriding of AISI316L stainless steel were investigated. Different temperatures and durations were applied in boriding operations and hardness, optical microscopy, XRD, EPMA and SEM studies were performed to detect the properties of boride layers. It was found that thickness of boride layer increased with increasing temperature and time; the basic phase in the boride layer formed was Fe2B and FeB phase also formed. It was also found that surface hardness values of borided materials increased depending on temperature and time of boriding process; surface hardness values of borided materials are approximately 10 times higher than surface hardness values of non-borided AISI316L stainless steel and formation activation energy of boride layer is 149.3 kjmol-1.