Quirine van der Zander

Mrs. Quirine van der Zander

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
QZQuirine van der Zander
Quirine van der Zander
MLMirjam C. M. van der Ende - van Loon
Mirjam C. M. van der Ende - van Loon
JJJanneke M. M. Janssen
Janneke M. M. Janssen
BWBjorn Winkens
Bjorn Winkens
FSFons van der Sommen
Fons van der Sommen
ESErik J. Schoon
Erik J. Schoon
Artificial intelligence (AI) is entering into daily life and has the potential to play a significant role in healthcare. Aim was to investigate the perspectives (knowledge, experience, and opinion) on AI in healthcare among patients with gastrointestinal (GI) disorders, gastroenterologists, and GI-fellows. In this prospective questionnaire study 377 GI-patients, 35 gastroenterologists, and 45 GI-fellows participated. Of GI-patients, 62.5% reported to be familiar with AI and 25.0% of GI-physicians had work-related experience with AI. GI-patients preferred their physicians to use AI (mean 3.9) and GI-physicians were willing to use AI (mean 4.4, on 5-point Likert-scale). More GI-physicians believed in an increase in quality of care (81.3%) than GI-patients (64.9%, χ2(2) = 8.2, p = 0.017). GI-fellows expected AI implementation within 6.0 years, gastroenterologists within 4.2 years (t(76) = − 2.6, p = 0.011), and GI-patients within 6.1 years (t(193) = − 2.0, p = 0.047). GI-patients and GI-physicians agreed on the most important advantages of AI in healthcare: improving quality of care, time saving, and faster diagnostics and shorter waiting times. The most important disadvantage for GI-patients was the potential loss of personal contact, for GI-physicians this was insufficiently developed IT infrastructures. GI-patients and GI-physicians hold positive perspectives towards AI in healthcare. Patients were significantly more reserved compared to GI-fellows and GI-fellows were more reserved compared to gastroenterologists.

23 December 2020 in Endoscopy
Verified
Journal Article
Closed access
PDF file
QZQuirine van der Zander
Quirine van der Zander
RSRamon Michel Schreuder
Ramon Michel Schreuder
RFRoger Fonollà
Roger Fonollà
TSThom Scheeve
Thom Scheeve
Fons van der SommenFons van der Sommen
Fons van der Sommen
ESErik J. Schoon
Erik J. Schoon
Background Optical diagnosis of colorectal polyps remains challenging. Image-enhancement techniques such as narrow-band imaging and blue-light imaging (BLI) can improve optical diagnosis. We developed and prospectively validated a computer-aided diagnosis system (CADx) using high-definition white-light (HDWL) and BLI images, and compared the system with the optical diagnosis of expert and novice endoscopists. Methods CADx characterized colorectal polyps by exploiting artificial neural networks. Six experts and 13 novices optically diagnosed 60 colorectal polyps based on intuition. After 4 weeks, the same set of images was permuted and optically diagnosed using the BLI Adenoma Serrated International Classification (BASIC). Results CADx had a diagnostic accuracy of 88.3 % using HDWL images and 86.7 % using BLI images. The overall diagnostic accuracy combining HDWL and BLI (multimodal imaging) was 95.0 %, which was significantly higher than that of experts (81.7 %, P = 0.03) and novices (66.7 %, P < 0.001). Sensitivity was also higher for CADx (95.6 % vs. 61.1 % and 55.4 %), whereas specificity was higher for experts compared with CADx and novices (95.6 % vs. 93.3 % and 93.2 %). For endoscopists, diagnostic accuracy did not increase when using BASIC, either for experts (intuition 79.5 % vs. BASIC 81.7 %, P = 0.14) or for novices (intuition 66.7 % vs. BASIC 66.5 %, P = 0.95). Conclusion CADx had a significantly higher diagnostic accuracy than experts and novices for the optical diagnosis of colorectal polyps. Multimodal imaging, incorporating both HDWL and BLI, improved the diagnostic accuracy of CADx. BASIC did not increase the diagnostic accuracy of endoscopists compared with intuitive optical diagnosis.

23 February 2022 in Digestive Endoscopy
Verified
Journal Article
Open access
PDF file
ARAnkie Reumkens
Ankie Reumkens
QZQuirine van der Zander
Quirine van der Zander
BWBjorn Winkens
Bjorn Winkens
RBRoel Bogie
Roel Bogie
CBChristine Minke Bakker
Christine Minke Bakker
AMAd A. M. Masclee
Ad A. M. Masclee
Background and study aims: We conducted a systematic review and meta‐analysis of population‐based studies to explore pooled prevalence and magnitude of electrolyte changes after bowel preparation for colonoscopy based on the most recent guidelines.Patients and methods: PubMed and Cochrane were queried for population‐based studies examining changes in electrolyte values after bowel preparation, published by July 1, 2021. We report prevalences of serum hypokalemia, hyponatremia, hyperphosphatemia, and hypocalcemia after bowel preparation and changes in mean electrolyte values after vs. before bowel preparation using sodium phosphate (NaP) and polyethylene glycol (PEG).Results: Thirteen studies met the inclusion criteria; 2386 unique patients were included. Overall, hypokalemia was found in 17.2% (95% CI 6.7, 30.9) in the NaP group vs. 4.8% (95% CI 0.27, 13.02) in the PEG group. The magnitude of potassium decrease after NaP bowel preparation was significantly increased compared to PEG (mean difference −0.38; 95% CI −0.49 to −0.27, P < 0.001). No study reported on major complications.Conclusions: Hypokalemia was found in 17.2% of patients after bowel preparation with NaP and in 4.8% of patients with PEG, a finding that is clinically relevant with respect to choosing the type of bowel preparation. The magnitude of the potassium decrease after NaP was significantly higher compared to PEG. These data provide the evidence that supports the recommendation of the European Society of Gastrointestinal Endoscopy against routine use of NaP for bowel preparation.

22 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RFRoger Fonolla
Roger Fonolla
QZQuirine van der Zander
Quirine van der Zander
RSRamon M. Schreuder
Ramon M. Schreuder
AMA.A.M. Masclee
A.A.M. Masclee
ESErik J. Schoon
Erik J. Schoon
PWPeter H. N. de With
Peter H. N. de With
Colorectal polyps are critical indicators of colorectal cancer (CRC). Blue Laser Imaging and Linked Color Imaging are two modalities that allow improved visualization of the colon. In conjunction with the Blue Laser Imaging (BLI) Adenoma Serrated International Classification (BASIC) classification, endoscopists are capable of distinguishing benign and pre-malignant polyps. Despite these advancements, this classification still prevails a high misclassification rate for pre-malignant colorectal polyps. This work proposes a computer aided diagnosis (CADx) system that exploits the additional information contained in two novel imaging modalities, enabling more informative decision-making during colonoscopy. We train and benchmark six commonly used CNN architectures and compare the results with 19 endoscopists that employed the standard clinical classification model (BASIC). The proposed CADx system for classifying colorectal polyps achieves an area under the curve (AUC) of 0.97. Furthermore, we incorporate visual explanatory information together with a probability score, jointly computed from White Light, Blue Laser Imaging, and Linked Color Imaging. Our CADx system for automatic polyp malignancy classification facilitates future advances towards patient safety and may reduce time-consuming and costly histology assessment.

26 June 2024 in Gastrointestinal Endoscopy
Verified
Journal Article
Open access
QZQuirine van der Zander
Quirine van der Zander
RRRachel Roumans
Rachel Roumans
CKCarolus H.J. Kusters
Carolus H.J. Kusters
NDNikoo Dehghani
Nikoo Dehghani
AMAd A.M. Masclee
Ad A.M. Masclee
ESErik J. Schoon
Erik J. Schoon
Computer-aided diagnosis (CADx) for optical diagnosis of colorectal polyps is thoroughly investigated. However, studies on human-artificial intelligence (AI) interaction are lacking. Aim was to investigate endoscopists' trust in CADx by evaluating whether communicating a calibrated algorithm confidence improved trust. Endoscopists optically diagnosed 60 colorectal polyps. Initially, endoscopists diagnosed the polyps without CADx assistance (initial diagnosis). Immediately afterwards, the same polyp was again shown with CADx prediction; either only a prediction (benign or pre-malignant) or a prediction accompanied by a calibrated confidence score (0-100). A confidence score of 0 indicated a benign prediction, 100 a (pre-)malignant prediction. In half of the polyps CADx was mandatory, for the other half CADx was optional. After reviewing the CADx prediction, endoscopists made a final diagnosis. Histopathology was used as gold standard. Endoscopists' trust in CADx was measured as CADx prediction utilization; the willingness to follow CADx predictions when the endoscopists initially disagreed with the CADx prediction. Twenty-three endoscopists participated. Presenting CADx predictions increased the endoscopists' diagnostic accuracy (69.3% initial vs 76.6% final diagnosis, p<0.001). The CADx prediction was utilized in 36.5% (n=183/501) disagreements. Adding a confidence score led to a lower CADx prediction utilization, except when the confidence score surpassed 60. A mandatory CADx decreased CADx prediction utilization compared to an optional CADx. Appropriate trust, utilizing correct or disregarding incorrect CADx predictions was 48.7% (n=244/501). Appropriate trust was common and CADx prediction utilization was highest for the optional CADx without confidence scores. These results express the importance of a better understanding of human-AI interaction.

19 August 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
QZQuirine van der Zander
Quirine van der Zander
ARAnkie Reumkens
Ankie Reumkens
BVBas van de Valk
Bas van de Valk
Bjorn WinkensBjorn Winkens
Bjorn Winkens
AMA.A.M. Masclee
A.A.M. Masclee
RRRogier J J de Ridder
Rogier J J de Ridder
Background: Adequate bowel preparation is essential for the visualization of the colonic mucosa during colonoscopy. However, the rate of inadequate bowel preparation is still high, ranging from 18% to 35%; this may lead to a higher risk of missing clinically relevant lesions, procedural difficulties, prolonged procedural time, an increased number of interval colorectal carcinomas, and additional health care costs. Objective: The aims of this study are to compare bowel preparation instructions provided via a personalized smartphone app (Prepit, Ferring B V) with regular written instructions for bowel preparation to improve bowel preparation quality and to evaluate patient satisfaction with the bowel preparation procedure. Methods: Eligible patients scheduled for an outpatient colonoscopy were randomized to a smartphone app group or a control group. Both the groups received identical face-to-face education from a research physician, including instructions about the colonoscopy procedure, diet restrictions, and laxative intake. In addition, the control group received written information, whereas the smartphone app group was instructed to use the smartphone app instead of the written information for the actual steps of the bowel preparation schedule. All patients used bisacodyl and sodium picosulfate with magnesium citrate as laxatives. The quality of bowel preparation was scored using the Boston Bowel Preparation Scale (BBPS) by blinded endoscopists. Patient satisfaction was measured using the Patient Satisfaction Questionnaire-18. Results: A total of 87 patients were included in the smartphone app group and 86 in the control group. The mean total BBPS score was significantly higher in the smartphone app group (mean 8.3, SD 0.9) than in the control group (mean 7.9, SD 1.2; P=.03). The right colon showed a significantly higher bowel preparation score in the smartphone app group (mean 2.7, SD 0.5 vs mean 2.5, SD 0.6; P=.04). No significant differences were observed in segment scores for the mean transverse colon (mean 2.8, SD 0.4 vs mean 2.8, SD 0.4; P=.34) and left colon (mean 2.8, SD 0.4 vs mean 2.6, SD 0.5; P=.07). General patient satisfaction was high for the smartphone app group (mean 4.4, SD 0.7) but showed no significant difference when compared with the control group (mean 4.3, SD 0.8; P=.32). Conclusions: Our personalized smartphone app significantly improved bowel preparation quality compared with regular written instructions for bowel preparation. In particular, in the right colon, the BBPS score improved, which is of clinical relevance because the right colon is considered more difficult to clean and the polyp detection rate in the right colon improves with improvement of bowel cleansing of the right colon. No further improvement in patient satisfaction was observed compared with patients receiving regular written instructions. Trial Registration: ClinicalTrials.gov NCT03677050; https://clinicaltrials.gov/ct2/show/NCT03677050