Background Optical diagnosis of colorectal polyps remains challenging. Image-enhancement techniques such as narrow-band imaging and blue-light imaging (BLI) can improve optical diagnosis. We developed and prospectively validated a computer-aided diagnosis system (CADx) using high-definition white-light (HDWL) and BLI images, and compared the system with the optical diagnosis of expert and novice endoscopists. Methods CADx characterized colorectal polyps by exploiting artificial neural networks. Six experts and 13 novices optically diagnosed 60 colorectal polyps based on intuition. After 4 weeks, the same set of images was permuted and optically diagnosed using the BLI Adenoma Serrated International Classification (BASIC). Results CADx had a diagnostic accuracy of 88.3 % using HDWL images and 86.7 % using BLI images. The overall diagnostic accuracy combining HDWL and BLI (multimodal imaging) was 95.0 %, which was significantly higher than that of experts (81.7 %, P = 0.03) and novices (66.7 %, P < 0.001). Sensitivity was also higher for CADx (95.6 % vs. 61.1 % and 55.4 %), whereas specificity was higher for experts compared with CADx and novices (95.6 % vs. 93.3 % and 93.2 %). For endoscopists, diagnostic accuracy did not increase when using BASIC, either for experts (intuition 79.5 % vs. BASIC 81.7 %, P = 0.14) or for novices (intuition 66.7 % vs. BASIC 66.5 %, P = 0.95). Conclusion CADx had a significantly higher diagnostic accuracy than experts and novices for the optical diagnosis of colorectal polyps. Multimodal imaging, incorporating both HDWL and BLI, improved the diagnostic accuracy of CADx. BASIC did not increase the diagnostic accuracy of endoscopists compared with intuitive optical diagnosis.
Barrett’s esopaghagus (BE) is a known precursor of esophageal adenocarcinoma (EAC). Patients with BE undergo regular surveillance to early detect stages of EAC. Volumetric laser endomicroscopy (VLE) is a novel technology incorporating a second-generation form of optical coherence tomography and is capable of imaging the inner tissue layers of the esophagus over a 6 cm length scan. However, interpretation of full VLE scans is still a challenge for human observers. In this work, we train an ensemble of deep convolutional neural networks to detect neoplasia in 45 BE patients, using a dataset of images acquired with VLE in a multi-center study. We achieve an area under the receiver operating characteristic curve (AUC) of 0.96 on the unseen test dataset and we compare our results with previous work done with VLE analysis, where only AUC of 0.90 was achieved via cross-validation on 18 BE patients. Our method for detecting neoplasia in BE patients facilitates future advances on patient treatment and provides clinicians with new assisting solutions to process and better understand VLE data.
1 March 2020 in Computerized Medical Imaging and Graphics
Barrett cancer is a treatable disease when detected at an early stage. However, current screening protocols are often not effective at finding the disease early. Volumetric Laser Endomicroscopy (VLE) is a promising new imaging tool for finding dysplasia in Barrett's esophagus (BE) at an early stage, by acquiring cross-sectional images of the microscopic structure of BE up to 3-mm deep. However, interpretation of VLE scans is difficult for medical doctors due to both the size and subtlety of the gray-scale data. Therefore, algorithms that can accurately find cancerous regions are very valuable for the interpretation of VLE data. In this study, we propose a fully-automatic multi-step Computer-Aided Detection (CAD) algorithm that optimally leverages the effectiveness of deep learning strategies by encoding the principal dimension in VLE data. Additionally, we show that combining the encoded dimensions with conventional machine learning techniques further improves results while maintaining interpretability. Furthermore, we train and validate our algorithm on a new histopathologically validated set of in-vivo VLE snapshots. Additionally, an independent test set is used to assess the performance of the model. Finally, we compare the performance of our algorithm against previous state-of-the-art systems. With the encoded principal dimension, we obtain an Area Under the Curve (AUC) and F1 score of 0.93 and 87.4% on the test set respectively. We show this is a significant improvement compared to the state-of-the-art of 0.89 and 83.1%, respectively, thereby demonstrating the effectiveness of our approach.
30 January 2020 in Journal of Medical Internet Research
Background: There is a need for shorter-length assessments that capture patient questionnaire data while attaining high data quality without an undue response burden on patients. Computerized adaptive testing (CAT) and classification and regression tree (CART) methods have the potential to meet these needs and can offer attractive options to shorten questionnaire lengths. Objective: The objective of this study was to test whether CAT or CART was best suited to reduce the number of questionnaire items in multiple domains (eg, anxiety, depression, quality of life, and social support) used for a needs assessment procedure (NAP) within the field of cardiac rehabilitation (CR) without the loss of data quality. Methods: NAP data of 2837 CR patients from a multicenter Cardiac Rehabilitation Decision Support System (CARDSS) Web-based program was used. Patients used a Web-based portal, MyCARDSS, to provide their data. CAT and CART were assessed based on their performances in shortening the NAP procedure and in terms of sensitivity and specificity. Results: With CAT and CART, an overall reduction of 36% and 72% of NAP questionnaire length, respectively, was achieved, with a mean sensitivity and specificity of 0.765 and 0.817 for CAT, 0.777 and 0.877 for classification trees, and 0.743 and 0.40 for regression trees, respectively. Conclusions: Both CAT and CART can be used to shorten the questionnaires of the NAP used within the field of CR. CART, however, showed the best performance, with a twice as large overall decrease in the number of questionnaire items of the NAP compared to CAT and the highest sensitivity and specificity. To our knowledge, our study is the first to assess the differences in performance between CAT and CART for shortening questionnaire lengths. Future research should consider administering varied assessments of patients over time to monitor their progress in multiple domains. For CR professionals, CART integrated with MyCARDSS would provide a feedback loop that informs the rehabilitation progress of their patients by providing real-time patient measurements.
Barrett's esopaghagus (BE) is a known precursor of esophageal adenocarcinoma (EAC). Patients with BE undergo regular surveillance to early detect stages of EAC. Volumetric laser endomicroscopy (VLE) is a novel technology capable of imaging the inner tissue layers of the esophagus over a 6-cm length scan. However, interpretation of full VLE scans is still a challenge for human observers. In this work, we train an ensemble of deep convolutional neural networks to detect neoplasia in BE patients, using a dataset of images acquired with VLE in a multicenter study. We achieve values of AUC=$0.96$ on the unseen test dataset and we compare our results with previous work done with VLE analysis. Our method for detecting neoplasia in BE patients facilitates future advances on patient treatment and provides clinicians with new assisting solutions to process and better understand VLE data.
Accurate endoscopic differentiation on resection of colorectal polyps (CRPs) (resect-discard or diagnose-leave strategies) increases cost-efficiency and reduces patient risk. We aim to develop a classification algorithm for automated differentiation of CRPs, by following the validated clinical Work-group serrAted polypS and Polyposis (WASP) classification scheme. Quantitative image features are investigated for each individual WASP criterion and classification is performed by conventional SVM. The technical WASP model results in areas under the curve of 0.87−0.95 and accuracies of 78−89%. Predicting polyp histology using model-based learning out-performs medical experts (accuracy, 87−93% vs 86 87%). Direct classification predicts more premalignant polyps−as being benign, compared to the automated WASP scheme. These errors do not occur when including ROC characteristics to the WASP model. The proposed WASP model is the first automated system, competing with medical expert classification.