José M. Gonzalez-Méijome

Prof. Dr. José M. Gonzalez-Méijome

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TFTeresa Ferrer-Blasco
Teresa Ferrer-Blasco
RMRobert Montés-Micó
Robert Montés-Micó
SPSofia C. Peixoto-De-Matos
Sofia C. Peixoto-De-Matos
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
Alejandro CerviñoAlejandro Cerviño
Alejandro Cerviño
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates. University of Valencia, Valencia, Spain. Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges. Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in older groups (Kruskal-Wallis, P<.01). In 13.2% of eyes, no corneal astigmatism was present; in 64.4%, corneal astigmatism was between 0.25 and 1.25 diopters (D) and in 22.2%, it was 1.50 D or higher. Corneal astigmatism less than 1.25 D was present in most cataract surgery candidates; it was higher in about 22%, with slight differences between the various age ranges. This information is useful for intraocular lens (IOL) manufacturers to evaluate which age ranges concentrate the parameters most frequently needed in sphere and cylinder powers and for surgeons to evaluate which IOLs provide the most effective power range.

1 October 2011 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
Paulo FernandesPaulo Fernandes
Paulo Fernandes
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
DCDavid Madrid Costa
David Madrid Costa
TFTeresa Ferrer-Blasco
Teresa Ferrer-Blasco
JJJorge Jorge
Jorge Jorge
RMRobert Montés-Micó
Robert Montés-Micó
PURPOSE: To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS: A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported complications using the latest ICL designs. RESULTS: Cataract was the major postoperative complication reported: 136 (5.2%) in 2592 eyes. Of those, 43.4% (n=59) were reported within 1 year, 15.4% (n=21) between 1 and 3 years, and 35.3% (n=48) ≥3 years after ICL implantation. Twenty-one (15.4%) cataracts were reported as surgically induced, 46 (33.8%) eyes had poor vault (<200 μm), and cataract surgery was carried out in 27.9% (n=38) of eyes. Early acute intraocular pressure increase was also reported to be relatively frequent, whereas acute pupillary block was less frequent and mostly resolved with additional iridotomies. A total of 42 ICLs were explanted due to cataract and IOP. Reported endothelial cell loss varied from 9.9% at 2 years to 3.7% 4 years postoperatively. This loss was reported to be more pronounced within the first 1 to 2 years, with stability or lower progression after that time. CONCLUSIONS: The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon’s learning curve, might be factors in the decreased occurrence of postoperative complications reported currently.

1 August 2014 in Contact Lens and Anterior Eye
Verified
Journal Article
Closed access
EWEef van der Worp
Eef van der Worp
DBDina Bornman
Dina Bornman
DFDaniela Lopes Ferreira
Daniela Lopes Ferreira
MFMiguel Faria-Ribeiro
Miguel Faria-Ribeiro
NGNery Garcia-Porta
Nery Garcia-Porta
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome

1 October 2013 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
Lyndon JonesLyndon Jones
Lyndon Jones
NBNoel A. Brennan
Noel A. Brennan
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
JLJohn Lally
John Lally
CMCarole Maldonado-Codina
Carole Maldonado-Codina
JNJason J. Nichols
Jason J. Nichols

1 May 2010 in Optometry and Vision Science
Verified
Journal Article
Closed access
António QueirósAntónio Queirós
António Queirós
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
JJJorge Jorge
Jorge Jorge
CVCésar Villa‐Collar
César Villa‐Collar
AGAngel R. Gutiérrez
Angel R. Gutiérrez

1 May 2011 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JAJosé F. Alfonso
José F. Alfonso
BBBegoña Baamonde
Begoña Baamonde
LFLuis Fernández-Vega
Luis Fernández-Vega
Paulo FernandesPaulo Fernandes
Paulo Fernandes
JGJosé M. Gonzalez-Méijome
José M. Gonzalez-Méijome
RMRobert Montés-Micó
Robert Montés-Micó
To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Cohort study. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were evaluated for 5 years after implantation of the Visian Implantable Collamer Lens pIOL for moderate to high myopia. The mean spherical equivalent (188 eyes) decreased from -11.17 diopters (D) ± 3.40 (SD) preoperatively to -0.88 ± 0.72 D 5 years postoperatively. The mean change in refraction from 1 month to 5 years was -0.65 ± 0.65 D. The mean UDVA and CDVA (Snellen decimal) were 0.69 ± 0.26 and 0.83 ± 0.15, respectively. The mean safety and efficacy indices were 1.27 ± 0.33 and 0.89 ± 0.35, respectively. No eye lost more than 2 lines of visual acuity; 70% achieved 0.80 or better CDVA. Three eyes (1.6%) developed late anterior subcapsular cataract that was clinically significant in 1 case, leading to pIOL removal and phacoemulsification. Of the 3 eyes (1.6%) with a mild transient increase in intraocular pressure (up to 27 mm Hg), none required a second surgical procedure or prolonged topical medication. The total endothelial cell loss (considered cumulatively at consecutive intervals through 5 years) was 7.7%. There was a tendency toward decreased pIOL vault decrease over time. No vision-threatening complications occurred. Implantation of the collagen copolymer pIOL for moderate to high myopia was safe and effective and provided long-term predictable, stable refractive results.