PURPOSE: To review the peer-reviewed literature reporting postoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS: A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported complications using the latest ICL designs. RESULTS: Cataract was the major postoperative complication reported: 136 (5.2%) in 2592 eyes. Of those, 43.4% (n=59) were reported within 1 year, 15.4% (n=21) between 1 and 3 years, and 35.3% (n=48) ≥3 years after ICL implantation. Twenty-one (15.4%) cataracts were reported as surgically induced, 46 (33.8%) eyes had poor vault (<200 μm), and cataract surgery was carried out in 27.9% (n=38) of eyes. Early acute intraocular pressure increase was also reported to be relatively frequent, whereas acute pupillary block was less frequent and mostly resolved with additional iridotomies. A total of 42 ICLs were explanted due to cataract and IOP. Reported endothelial cell loss varied from 9.9% at 2 years to 3.7% 4 years postoperatively. This loss was reported to be more pronounced within the first 1 to 2 years, with stability or lower progression after that time. CONCLUSIONS: The majority of reported complications after ICL implantation are cataract formation. The improvements in lens geometry and more accurate nomograms applied to the selection of the lens to be implanted, in addition to the surgeon’s learning curve, might be factors in the decreased occurrence of postoperative complications reported currently.
To compare the central postoperative vault of a phakic intraocular lens (pIOL) to correct myopia, myopic astigmatism, and hyperopia and identify ocular and lens parameters that might predict the vault amount. Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Cohort study. Three months after implantation of Implantable Collamer Lens pIOLs to correct myopia, hyperopia, and myopic astigmatism, central vault was measured using optical coherence tomography. Patients were divided into groups according to the preoperative anterior chamber depth (ACD) to compare the effects of ACD, white-to-white (WTW) distance, and lens diameter on postoperative pIOL vault. Hyperopic pIOLs had statistically significantly lower vault followed by myopic pIOLs and toric pIOLs, which had a higher mean value and narrower range (260 to 860 μm). Measured vaults had a positive correlation with preoperative ACD (r = .32, P<.001) and WTW (r = .29, P<.001) and a negative correlation with preoperative spherical equivalent (SE) (r = -0.21, P<.001) and patient age (r = -0.12, P=.025). Eyes with a vault of 250 μm or less had a shallower ACD than eyes with a vault between 250 μm and 750 μm (mean difference -0.11 mm; P=.012) and those with a vault greater than 750 μm (mean difference -0.25 mm; P<.001). Central vaulting was lower in hyperopic eyes. Current nomograms for pIOL diameter selection based on ACD and WTW might yield ideal vault and may have to be adjusted for older patients, shallower ACD, lower WTW, and lower SE.