Ana Rita S R Ribeiro

Ms. Ana Rita S R Ribeiro


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ARAna Rita S R Ribeiro
Ana Rita S R Ribeiro
PDPabitra Dahal
Pabitra Dahal
AGAriel Guerreiro
Ariel Guerreiro
Pedro JorgePedro Jorge
Pedro Jorge
JVJaime Viegas
Jaime Viegas
The development of economical optical devices with a reduced footprint foreseeing manipulation, sorting and detection of single cells and other micro particles have been encouraged by cellular biology requirements. Nonetheless, researchers are still ambitious for advances in this field. This paper presents Fresnel zone and phase plates fabricated on mode expanded optical fibres for optical trapping. The diffractive structures were fabricated using focused ion beam milling. The zone plates presented in this work have focal distance of ~5 µm, while the focal distance of the phase plates is ~10 µm. The phase plates are implemented in an optical trapping configuration, and 2D manipulation and detection of 8 µm PMMA beads and yeast cells is reported. This enables new applications for optical trapping setups based on diffractive optical elements on optical fibre tips, where feedback systems can be integrated to automatically detect, manipulate and sort cells.

2 May 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
ARAna Rita S R Ribeiro
Ana Rita S R Ribeiro
PDPabitra Dahal
Pabitra Dahal
AGAriel Guerreiro
Ariel Guerreiro
Pedro JorgePedro Jorge
Pedro Jorge
JVJaime Viegas
Jaime Viegas
This Letter reports a new method for the generation of optical vortices using a micropatterned optical fiber tip. Here, a spiral phase plate (2π phase shift) is micromachined on the tip of an optical fiber using a focused ion beam. This is a high resolution method that allows milling the fibers with nanoscale resolution. The plate acts as a beam tailoring system, transforming the fundamental guided mode, specifically a Gaussian mode, into the Laguerre–Gaussian mode (LG01), which carries orbital angular momentum. The experimental results are supported by computational simulations based on the finite-difference time-domain method.

27 February 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JPJoana S. Paiva
Joana S. Paiva
ARAna Rita S R Ribeiro
Ana Rita S R Ribeiro
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
CRCarla C. Rosa
Carla C. Rosa
Pedro JorgePedro Jorge
Pedro Jorge
Recent trends on microbiology point out the urge to develop optical micro-tools with multifunctionalities such as simultaneous manipulation and sensing. Considering that miniaturization has been recognized as one of the most important paradigms of emerging sensing biotechnologies, optical fiber tools, including Optical Fiber Tweezers (OFTs), are suitable candidates for developing multifunctional small sensors for Medicine and Biology. OFTs are flexible and versatile optotools based on fibers with one extremity patterned to form a micro-lens. These are able to focus laser beams and exert forces onto microparticles strong enough (piconewtons) to trap and manipulate them. In this paper, through an exploratory analysis of a 45 features set, including time and frequency-domain parameters of the back-scattered signal of particles trapped by a polymeric lens, we created a novel single feature able to differentiate synthetic particles (PMMA and Polystyrene) from living yeasts cells. This single statistical feature can be useful for the development of label-free hybrid optical fiber sensors with applications in infectious diseases detection or cells sorting. It can also contribute, by revealing the most significant information that can be extracted from the scattered signal, to the development of a simpler method for particles characterization (in terms of composition, heterogeneity degree) than existent technologies.

21 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
SRSandra M. Rodrigues
Sandra M. Rodrigues
JPJoana S. Paiva
Joana S. Paiva
ARAna Rita S R Ribeiro
Ana Rita S R Ribeiro
Olivier SopperaOlivier Soppera
Olivier Soppera
JCJoão Paulo Silva Cunha
João Paulo Silva Cunha
Pedro JorgePedro Jorge
Pedro Jorge
Optical fiber tweezers have been gaining prominence in several applications in Biology and Medicine. Due to their outstanding focusing abilities, they are able to trap and manipulate microparticles, including cells, needing any physical contact and with a low degree of invasiveness to the trapped cell. Recently, we proposed a fiber tweezer configuration based on a polymeric micro-lens on the top of a single mode fiber, obtained by a self-guided photopolymerization process. This configuration is able to both trap and identify the target through the analysis of short-term portions of the back-scattered signal. In this paper, we propose a variant of this fabrication method, capable of producing more robust fiber tips, which produce stronger trapping effects on targets by as much as two to ten fold. These novel lenses maintain the capability of distinguish the different classes of trapped particles based on the back-scattered signal. This novel fabrication method consists in the introduction of a multi mode fiber section on the tip of a single mode (SM) fiber. A detailed description of how relevant fabrication parameters such as the length of the multi mode section and the photopolymerization laser power can be tuned for different purposes (e.g., microparticles trapping only, simultaneous trapping and sensing) is also provided, based on both experimental and theoretical evidences.

5 April 2024 in eLife
Verified
Journal Article
Open access
MSMagali Seguret
Magali Seguret
PDPatricia Davidson
Patricia Davidson
SRStijn Robben
Stijn Robben
JCJOUVE Charlène
JOUVE Charlène
CPCeline Pereira
Celine Pereira
JHJean-Sébastien Hulot
Jean-Sébastien Hulot
We developed a 96-well plate assay which allows fast, reproducible, and high-throughput generation of 3D cardiac rings around a deformable optically transparent hydrogel (polyethylene glycol [PEG]) pillar of known stiffness. Human induced pluripotent stem cell-derived cardiomyocytes, mixed with normal human adult dermal fibroblasts in an optimized 3:1 ratio, self-organized to form ring-shaped cardiac constructs. Immunostaining showed that the fibroblasts form a basal layer in contact with the glass, stabilizing the muscular fiber above. Tissues started contracting around the pillar at D1 and their fractional shortening increased until D7, reaching a plateau at 25±1%, that was maintained up to 14 days. The average stress, calculated from the compaction of the central pillar during contractions, was 1.4±0.4 mN/mm2. The cardiac constructs recapitulated expected inotropic responses to calcium and various drugs (isoproterenol, verapamil) as well as the arrhythmogenic effects of dofetilide. This versatile high-throughput assay allows multiple in situ mechanical and structural readouts.

7 October 2016 in Micromachines
Verified
Journal Article
Open access
PDF file
FPFábio M. Pereira
Fábio M. Pereira
IBIwona Bernacka-Wojcik
Iwona Bernacka-Wojcik
ARAna Rita S R Ribeiro
Ana Rita S R Ribeiro
MLMaria Teresa Lobato
Maria Teresa Lobato
Elvira FortunatoElvira Fortunato
Elvira Fortunato
AOAbel Oliva
Abel Oliva
This paper describes the development of a novel microfluidic platform for multifactorial analysis integrating four label-free detection methods: electrical impedance, refractometry, optical absorption and fluorescence. We present the rationale for the design and the details of the microfabrication of this multifactorial hybrid microfluidic chip. The structure of the platform consists of a three-dimensionally patterned polydimethylsiloxane top part attached to a bottom SU-8 epoxy-based negative photoresist part, where microelectrodes and optical fibers are incorporated to enable impedance and optical analysis. As a proof of concept, the chip functions have been tested and explored, enabling a diversity of applications: (i) impedance-based identification of the size of micro beads, as well as counting and distinguishing of erythrocytes by their volume or membrane properties; (ii) simultaneous determination of the refractive index and optical absorption properties of solutions; and (iii) fluorescence-based bead counting.