Arne De Brabandere

Mr. Arne De Brabandere


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
ABArne De Brabandere
Arne De Brabandere
Jill EmmerzaalJill Emmerzaal
Jill Emmerzaal
Annick TimmermansAnnick Timmermans
Annick Timmermans
IJIlse Jonkers
Ilse Jonkers
BVBenedicte Vanwanseele
Benedicte Vanwanseele
JDJesse Davis
Jesse Davis
Hip osteoarthritis patients exhibit changes in kinematics and kinetics that affect joint loading. Monitoring this load can provide valuable information to clinicians. For example, a patient's joint loading measured across different activities can be used to determine the amount of exercise that the patient needs to complete each day. Unfortunately, current methods for measuring joint loading require a lab environment which most clinicians do not have access to. This study explores employing machine learning to construct a model that can estimate joint loading based on sensor data obtained solely from a mobile phone. In order to learn such a model, we collected a dataset from 10 patients with hip osteoarthritis who performed multiple repetitions of nine different exercises. During each repetition, we simultaneously recorded 3D motion capture data, ground reaction force data, and the inertial measurement unit data from a mobile phone attached to the patient's hip. The 3D motion and ground reaction force data were used to compute the ground truth joint loading using musculoskeletal modeling. Our goal is to estimate the ground truth loading value using only the data captured by the sensors of the mobile phone. We propose a machine learning pipeline for learning such a model based on the recordings of a phone's accelerometer and gyroscope. When evaluated for an unseen patient, the proposed pipeline achieves a mean absolute error of 29% for the left hip and 36% for the right hip. While our approach is a step in the direction of using a minimal number of sensors to estimate joint loading outside the lab, developing a tool that is accurate enough to be applicable in a clinical context still remains an open challenge. It may be necessary to use sensors at more than one location in order to obtain better estimates.

29 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ABArne De Brabandere
Arne De Brabandere
TBTim Op De Beéck
Tim Op De Beéck
KSKurt H Schütte
Kurt H Schütte
WMWannes Meert
Wannes Meert
BVBenedicte Vanwanseele
Benedicte Vanwanseele
JDJesse Davis
Jesse Davis
Maximal oxygen uptake (VO2max) is often used to assess an individual’s cardiorespiratory fitness. However, measuring this variable requires an athlete to perform a maximal exercise test which may be impractical, since this test requires trained staff and specialized equipment, and may be hard to incorporate regularly into training programs. The aim of this study is to develop a new model for predicting VO2max by exploiting its relationship to heart rate and accelerometer features extracted during submaximal running. To do so, we analyzed data collected from 31 recreational runners (15 men and 16 women) aged 19-26 years who performed a maximal incremental test on a treadmill. During this test, the subjects’ heart rate and acceleration at three locations (the upper back, the lower back and the tibia) were continuously measured. We extracted a wide variety of features from the measurements of the warm-up and the first three stages of the test and employed a data-driven approach to select the most relevant ones. Furthermore, we evaluated the utility of combining different types of features. Empirically, we found that combining heart rate and accelerometer features resulted in the best model with a mean absolute error of 2.33 ml ⋅ kg−1 ⋅ min−1 and a mean absolute percentage error of 4.92%. The model includes four features: gender, body mass, the inverse of the average heart rate and the inverse of the variance of the total tibia acceleration during the warm-up stage of the treadmill test. Our model provides a practical tool for recreational runners in the same age range to estimate their VO2max from submaximal running on a treadmill. It requires two body-worn sensors: a heart rate monitor and an accelerometer positioned on the tibia.

16 May 2022 in Machine Learning
Verified
Journal Article
Closed access
PDF file
ABArne De Brabandere
Arne De Brabandere
TBTim Op De Beéck
Tim Op De Beéck
KHKilian Hendrickx
Kilian Hendrickx
WMWannes Meert
Wannes Meert
JDJesse Davis
Jesse Davis

18 January 2022 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
PDF file
Jill EmmerzaalJill Emmerzaal
Jill Emmerzaal
SRSam Van Rossom
Sam Van Rossom
RSRob Van der Straaten
Rob Van der Straaten
ABArne De Brabandere
Arne De Brabandere
KCKristoff Corten
Kristoff Corten
BVBenedicte Vanwanseele
Benedicte Vanwanseele

5 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Jill EmmerzaalJill Emmerzaal
Jill Emmerzaal
ABArne De Brabandere
Arne De Brabandere
YVYves Vanrompay
Yves Vanrompay
JVJulie Vranken
Julie Vranken
VSValerie Storms
Valerie Storms
Annick TimmermansAnnick Timmermans
Annick Timmermans
(1) Background: Joint loading is an important parameter in patients with osteoarthritis (OA). However, calculating joint loading relies on the performance of an extensive biomechanical analysis, which is not possible to do in a free-living situation. We propose the concept and design of a novel blended-care app called JOLO (Joint Load) that combines free-living information on activity with lab-based measures of joint loading in order to estimate a subject’s functional status. (2) Method: We used an iterative design process to evaluate the usability of the JOLO app through questionnaires. The user interfaces that resulted from the iterations are described and provide a concept for feedback on functional status. (3) Results: In total, 44 people (20 people with OA and 24 health-care providers) participated in the testing of the JOLO app. OA patients rated the latest version of the JOLO app as moderately useful. Therapists were predominantly positive; however, their intention to use JOLO was low due to technological issues. (4) Conclusion: We can conclude that JOLO is promising, but further technological improvements concerning activity recognition, the development of personalized joint loading predictions and a more comfortable means to carry the device are needed to facilitate its integration as a blended-care program.

28 July 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ABArne De Brabandere
Arne De Brabandere
CCChristos Chatzichristos
Christos Chatzichristos
WPWim Van Paesschen
Wim Van Paesschen
MVMaarten De Vos
Maarten De Vos
JDJesse Davis
Jesse Davis
Epileptic seizure detection aims to replace unreliable seizure diaries by a model that automatically detects seizures based on electroencephalography (EEG) sensors. However, developing such a model is difficult and time consuming as it requires manually searching for relevant features from complex EEG data. Domain experts may have a partial understanding of the EEG characteristics that indicate seizures, but this knowledge is often not sufficient to exhaustively enumerate all relevant features. To address this challenge, we investigate how automated feature construction may complement hand-crafted features for epileptic seizure detection. By means of an empirical comparison on a real-world seizure detection dataset, we evaluate the ability of automated feature construction to come up with new relevant features. We show that combining hand-crafted and automated features results in more accurate models compared to using hand-crafted features alone. Our findings suggest that future studies on developing EEG-based seizure detection models may benefit from features constructed using a combination of hand-crafted and automated feature engineering.