Laura Mezzanotte

Dr. Laura Mezzanotte

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Trends in Biotechnology
Verified
Journal Article
Closed access
LMLaura Mezzanotte
Laura Mezzanotte
MRMoniek van ‘t Root
Moniek van ‘t Root
HKHacer Karatas
Hacer Karatas
EGElena Goun
Elena Goun
CLClemens W.G.M. Löwik
Clemens W.G.M. Löwik

11 July 2010 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Elisa MicheliniElisa Michelini
Elisa Michelini
LCLuca Cevenini
Luca Cevenini
LMLaura Mezzanotte
Laura Mezzanotte
ACAndrea Coppa
Andrea Coppa
ARAldo Roda
Aldo Roda

9 January 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
MHMary P. Hall
Mary P. Hall
CWCarolyn C. Woodroofe
Carolyn C. Woodroofe
MWMonika G. Wood
Monika G. Wood
IQIvo Que
Ivo Que
MRMoniek Van’t Root
Moniek Van’t Root
LMLaura Mezzanotte
Laura Mezzanotte
The sensitivity of bioluminescence imaging in animals is primarily dependent on the amount of photons emitted by the luciferase enzyme at wavelengths greater than 620 nm where tissue penetration is high. This area of work has been dominated by firefly luciferase and its substrate, D-luciferin, due to the system’s peak emission (~ 600 nm), high signal to noise ratio, and generally favorable biodistribution of D-luciferin in mice. Here we report on the development of a codon optimized mutant of click beetle red luciferase that produces substantially more light output than firefly luciferase when the two enzymes are compared in transplanted cells within the skin of black fur mice or in deep brain. The mutant enzyme utilizes two new naphthyl-luciferin substrates to produce near infrared emission (730 nm and 743 nm). The stable luminescence signal and near infrared emission enable unprecedented sensitivity and accuracy for performing deep tissue multispectral tomography in mice.

14 March 2016 in Clinical Cancer Research
Verified
Journal Article
Closed access
PDF file
JKJan Willem Kleinovink
Jan Willem Kleinovink
PDPieter B. van Driel
Pieter B. van Driel
TSThomas J. Snoeks
Thomas J. Snoeks
NPNatasa Prokopi
Natasa Prokopi
MFMarieke F. Fransen
Marieke F. Fransen
FOFerry Ossendorp
Ferry Ossendorp
Purpose: The efficacy of immunotherapy against advanced cancer may be improved by combination strategies. Photodynamic therapy (PDT) is a local tumor ablation method based on localized activation of a photosensitizer, leading to oxygen radical-induced tumor cell death. PDT can enhance antitumor immune responses by release of antigen and danger signals, supporting combination protocols of PDT with immunotherapy. Experimental Design: We investigated the local and systemic immune effects of PDT after treatment of established tumors. In two independent aggressive mouse tumor models, TC-1 and RMA, we combined PDT with therapeutic vaccination using synthetic long peptides (SLP) containing epitopes from tumor antigens. Results: PDT of established tumors using the photosensitizer Bremachlorin resulted in significant delay of tumor outgrowth. Combination treatment of PDT with therapeutic SLP vaccination cured one third of mice. Importantly, all cured mice were fully protected against subsequent tumor rechallenge, and combination treatment of primary tumors led to eradication of distant secondary tumors, indicating the induction of a systemic antitumor immune response. Indeed, PDT by itself induced a significant CD8+ T-cell response against the tumor, which was increased when combined with SLP vaccination and essential for the therapeutic effect of combination therapy. Conclusions: We show that immunotherapy can be efficiently combined with PDT to eradicate established tumors, based on strong local tumor ablation and the induction of a robust systemic immune response. These results suggest combination of active immunotherapy with tumor ablation by PDT as a feasible novel treatment strategy for advanced cancer. Clin Cancer Res; 22(6); 1459–68. ©2015 AACR.

1 November 2013 in Contrast Media & Molecular Imaging
Verified
Journal Article
Closed access
LMLaura Mezzanotte
Laura Mezzanotte
MAMarkus Aswendt
Markus Aswendt
ATAnnette Tennstaedt
Annette Tennstaedt
RHRob Hoeben
Rob Hoeben
MHMathias Hoehn
Mathias Hoehn
CLClemens Löwik
Clemens Löwik

22 April 2011 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LMLaura Mezzanotte
Laura Mezzanotte
IQIvo Que
Ivo Que
EKEric Kaijzel
Eric Kaijzel
BBBruce Branchini
Bruce Branchini
ARAldo Roda
Aldo Roda
CLClemens Löwik
Clemens Löwik
Despite a plethora of bioluminescent reporter genes being cloned and used for cell assays and molecular imaging purposes, the simultaneous monitoring of multiple events in small animals is still challenging. This is partly attributable to the lack of optimization of cell reporter gene expression as well as too much spectral overlap of the color-coupled reporter genes. A new red emitting codon-optimized luciferase reporter gene mutant of Photinus pyralis, Ppy RE8, has been developed and used in combination with the green click beetle luciferase, CBG99. Human embryonic kidney cells (HEK293) were transfected with vectors that expressed red Ppy RE8 and green CBG99 luciferases. Populations of red and green emitting cells were mixed in different ratios. After addition of the shared single substrate, D-luciferin, bioluminescent (BL) signals were imaged with an ultrasensitive cooled CCD camera using a series of band pass filters (20 nm). Spectral unmixing algorithms were applied to the images where good separation of signals was observed. Furthermore, HEK293 cells that expressed the two luciferases were injected at different depth in the animals. Spectrally-separate images and quantification of the dual BL signals in a mixed population of cells was achieved when cells were either injected subcutaneously or directly into the prostate. We report here the re-engineering of different luciferase genes for in vitro and in vivo dual color imaging applications to address the technical issues of using dual luciferases for imaging. In respect to previously used dual assays, our study demonstrated enhanced sensitivity combined with spatially separate BL spectral emissions using a suitable spectral unmixing algorithm. This new D-luciferin-dependent reporter gene couplet opens up the possibility in the future for more accurate quantitative gene expression studies in vivo by simultaneously monitoring two events in real time.