Park Ji Su

Dr. Park Ji Su

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PSPark Ji Su
Park Ji Su
CLChang Min Lee
Chang Min Lee
SKSang-Mo Koo
Sang-Mo Koo
CKChoong Hyun Kim
Choong Hyun Kim
Traditional gait analysis systems based on 3D motion capture system require large, expensive equipment and specialists to operate the system, presenting time and space constraints. Although various studies have been conducted on developing wearable gait analysis devices, the results were discontinuous, there were limitations in dividing the gait phases, and appropriate responses to changes in physical conditions and walking speed were not demonstrated. To overcome these problems, the present study developed an insole device fitted with force sensing resistors for the measurement of the ground reaction force, and designed a gait analysis technique based on results from a gait experiment conducted on eight healthy male adults. This novel gait analysis algorithm examined the forward and lateral centers of the pressure values generated during gait, ratio of these two values for the division of the gait cycle into eight phases, and identification of the point when the weight support transition between the two feet occurred. The data acquisition system (DAS), comprising the developed insole device and wireless data transceiver, is expected to be applicable for activities of daily living because it can be manufactured as a small, lightweight wearable device, and the proposed gait analysis technique is unaffected by the walking speed and physical conditions of the wearer.

6 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PSPark Ji Su
Park Ji Su
CKChoong Hyun Kim
Choong Hyun Kim
Gait assessment is an important tool for determining whether a person has a gait disorder. Existing gait analysis studies have a high error rate due to the heel-contact-event-based technique. Our goals were to overcome the shortcomings of existing gait analysis techniques and to develop more objective indices for assessing gait disorders. This paper proposes a method for assessing gait disorders via the observation of changes in the center of pressure (COP) in the medial–lateral direction, i.e., COPx, during the gait cycle. The data for the COPx were used to design a gait cycle estimation method applicable to patients with gait disorders. A polar gaitogram was drawn using the gait cycle and COPx data. The difference between the areas inside the two closed curves in the polar gaitogram, area ratio index (ARI), and the slope of the tangential line common to the two closed curves were proposed as gait analysis indices. An experimental study was conducted to verify that these two indices can be used to differentiate between stroke patients and healthy adults. The findings indicated the potential of using the proposed polar gaitogram and indices to develop and apply wearable devices to assess gait disorders.

18 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
PSPark Ji Su
Park Ji Su
SKSang-Mo Koo
Sang-Mo Koo
CKChoong Hyun Kim
Choong Hyun Kim
The operation of wearable robots, such as gait rehabilitation robots, requires real-time classification of the standing or walking state of the wearer. This report explains a technique that measures the ground reaction force (GRF) using an insole device equipped with force sensing resistors, and detects whether the insole wearer is standing or walking based on the measured results. The technique developed in the present study uses the waveform length that represents the sum of the changes in the center of pressure within an arbitrary time window as the determining factor, and applies this factor to a conventional threshold method and an artificial neural network (ANN) model for classification of the standing and walking states. The results showed that applying the newly developed technique could significantly reduce classification errors due to shuffling movements of the patient, typically noticed in the conventional threshold method using GRF, i.e., real-time classification of the standing and walking states is possible in the ANN model. The insole device used in the present study can be applied not only to gait analysis systems used in wearable robot operations, but also as a device for remotely monitoring the activities of daily living of the wearer.

11 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PSPark Ji Su
Park Ji Su
BLBohyun Lee
Bohyun Lee
SPShinsuk Park
Shinsuk Park
CKChoong Hyun Kim
Choong Hyun Kim
Stride length (SL), foot clearance (FC), and foot progression angle (FPA) are the key parameters for diagnosing gait disorders. This study used the distance data between two feet measured by ultra-wideband (UWB) sensors installed on shoes and proposed a method for estimating the three gait parameters. Here, a method of compensating the offset of the UWB sensor and estimating the distances between a base sensor installed on one foot during the stance phase and three UWB sensors on the other during the swing phase was applied. Foot trajectory was acquired in a gait experiment with ten healthy adults walking on a treadmill. The results were compared with those obtained using a motion capture system (MCS). The UWBs sensor displayed average errors of 45.84 mm, 7.60 mm, and 2.82° for SL, FC, and FPA, respectively, compared with the MCS. A similar accuracy level was achieved in a previous study that used an inertial measurement unit (IMU). Thus, these results suggest that UWB sensors can be extensively applied to sensor systems used to analyze mobile gait systems.

9 January 2023 in Micro
Verified
Journal Article
Open access
PDF file
PSPark Ji Su
Park Ji Su
SKSang-Mo Koo
Sang-Mo Koo
CKChoong Hyun Kim
Choong Hyun Kim
In order to operate a gait rehabilitation device, it is necessary to accurately classify the states appearing in activities of daily living (ADLs). In the case of force sensing resistors (FSRs), which are often used as pressure sensors in gait analysis, it is desirable to replace them with other sensors because of their low durability. In the present study, capacitive-type pressure sensors, as an alternative to FSRs, were developed, and their performance was evaluated. In addition, the timed up and go test was performed to measure the ground reaction force in healthy individuals, and a machine learning technique was applied to the calculated biosignal parameters for the classification of five types of ADLs. The performance evaluation results showed that a sensor with thermoplastic polyurethane (substrate and dielectric layer material) and multiwall carbon nanotubes (conductive layer) has sufficient sensitivity and durability for use as a gait analysis pressure sensor. Moreover, when an overlapping filter was applied to the four-layer long short-term memory (LSTM) or the five-layer LSTM model developed for motion classification, the precision was greater or equal to 95%, and unstable errors did not occur. Therefore, when the pressure sensor and ADLs classification algorithm developed in this study are applied, it is expected that motion classification can be completed within a time range that does not affect the control of the gait rehabilitation device.

27 September 2023 in International Journal of Precision Engineering and Manufacturing
Verified
Journal Article
Open access
PDF file
BLBohyun Lee
Bohyun Lee
PSPark Ji Su
Park Ji Su
SPShinsuk Park
Shinsuk Park
CKChoong Hyun Kim
Choong Hyun Kim
Gait disorders can lower the quality of life of patients. Drop foot, a causative factor of deviated gait patterns, renders patients unable to lift their forefoot towards the body. Hence, a light and compact ankle–foot orthosis (AFO), which is the most common treatment for drop foot, must be designed, especially for patients with impaired lower limb muscles as oxygen consumption increases by 30% per 1.96 N load on their foot. Furthermore, the limited range of ankle angles in the first 10% of the gait cycle (GC) is a major drawback for patients with drop foot compared to healthy individuals. This limited range of ankle angles can be improved by gaining support from an AFO composed of shape memory alloy (SMA) actuators (SMA-AFO). Therefore, in this study, an SMA was used to fabricate a soft actuator to reduce the weight of the AFO. An adaptive frequency oscillator (AO) was implemented in real time for continuous gait phase detection. Walk tests were performed on a treadmill with the SMA-AFO attached to the participants (N = 3). The experimental results showed that the participants could lift their forefoot in the dorsiflexion direction with an ankle angle of 8.75° in the first 10% of the GC. Furthermore, the current required to operate the SMA actuator can be supplied to only 45.3% of the GC, reducing the power consumption. Therefore, the proposed SMA-AFO can be used in patients with drop foot.