Covalent organic frameworks (COFs) are an emerging class of photoactive materials, solely composed of light elements. Their ordered structure, crystallinity, and high porosity led to enormous worldwide attention in many research fields. The extensive π-electron conjugation, light-harvesting and charge transport characteristics make them a fascinating polymer for photocatalytic systems. Versatile selection of building blocks and innumerable synthetic methodologies enable them to be a robust platform for solar energy production. In this mini-review, we summarized recent progress and challenges of the design, construction, and applications of COFs-based photocatalysts, and also presented some perspectives on challenges.
The continuous advancement of science and technology has led to the widespread application of nuclear technology across a diverse spectrum of fields, including scientific research, industrial processes, and particularly the medical domain for diagnostics and therapeutics. This proliferation, while beneficial, necessitates stringent protective measures for personnel who may be exposed to various forms of ionizing radiation, such as X-rays, γ-rays, and neutrons. In this context, polymer-based composite materials have emerged as a pivotal class of shielding solutions. These materials are typically fabricated by incorporating functional fillers—containing elements with high atomic numbers for photon attenuation or neutron-absorbing isotopes—into a continuous polymer matrix. This design strategy synergizes the processability and lightweight nature of polymers with the superior radiation shielding efficacy of the dispersed fillers, thereby offering robust and adaptable protection for individuals in nuclear-related occupations. This paper provides a comprehensive analysis of this material system. It begins by elucidating the fundamental attenuation and shielding mechanisms that govern the interaction of radiation with matter, establishing the theoretical foundation for material design. Subsequently, the paper offers a detailed review of the development history and recent research progress in polymer-based radiation shielding, tracing its evolution from conventional lead-impregnated rubbers to modern nanocomposites. The current research status of various material types is systematically summarized, highlighting technical achievements and innovative breakthroughs, such as the use of multi-layered structures or hybrid fillers. Furthermore, the paper analyzes the critical selection criteria for polymer matrices, considering factors like radiation resistance, thermal stability, and mechanical properties. Finally, it synthesizes the key challenges that remain to be addressed in current materials and provides a forward-looking perspective on future development directions, aiming to guide subsequent research and development efforts in this critical field.
Conventional radiation-shielding composites usually contain lead, which results in high toxicity and poor portability. Tungsten (W) is an ideal radiation-shielding element that can replace lead due to its high atomic number and non-toxicity. In this work, radiation-shielding composites were prepared using natural rubber (NR) as a matrix and three different particle size powders, namely W, WO3 and WC, as fillers. The results show that, for X-rays, the linear attenuation coefficient of radiation-shielding composites based on natural rubber containing WC with a particle size of 50 μm (50 WC/NR) is 27.005 cm−1 at an X-ray tube voltage of 40 kV, which is more than 14 times the linear attenuation coefficient of NR. For γ-rays, a linear attenuation coefficient of 50 WC/NR achieves 8.320 cm−1 at 81 keV, which is over 55 times the linear attenuation coefficient of NR. In addition, 50 WC/NR had the highest elongation at break at 548.989% and had the lowest hardness at 62 HA. In summary, 50 WC/NR can be used as an alternative to traditional radiation-shielding materials containing lead and has wide application prospects.
Fluorine resin membranes with excellent chemical resistance have great potential for the application of high-performance chemical protective clothing. However, it is difficult to integrate fluorine resins into other materials such as fabrics due to their lower surface energy and poor bondability, making the fabrication of composite fabrics and the further seal splicing challenging. In this study, atmospheric pressure dielectric barrier discharge (DBD) plasma in helium (He) and helium/acrylic acid (He/AA) mixture atmospheres were used to modify two kinds of fluorine resins, ethylene tetrafluoroethylene (ETFE) and polytetrafluoroethylene (PTFE) membrane. The surface chemical properties, physical morphology, hydrophilicity and adhesion strength of the fluororesin membranes before and after plasma treatments were systematically analyzed. The results showed that the plasma treatment can modify the membrane surface at the nanoscale level without damaging the main body of the membrane. The hydrophilicity of the plasma-treated membrane was improved with the water contact angle decreasing from 95.83° to 49.9° for the ETFE membrane and from 109.9° to 67.8° for the PTFE membrane, respectively. The He plasma creates active sites on the membrane surface as well as etching the membrane surface, increasing the surface roughness. The He/AA plasma treatment introduces two types of polyacrylic acid (PAA)—deposited polyacrylic acid (d-PAA) and grafted polyacrylic acid (g-PAA)—on the membrane surface. Even after ultrasonic washing with acetone, g-PAA still existed stably and, as a result, improved the polarity and adhesion strength of fluororesin membranes. This work provides useful insights into the modification mechanism of DBD plasma on fluorine resins, with implications for developing effective strategies of integrating fluorine resin membrane to chemical protective clothing fabrics.
This study involved the preparation of natural rubber-based composites incorporating varying proportions of heavy metals and rare earth oxides (Sm2O3, Ta2O5, and Bi2O3). The investigation analyzed several parameters of the samples, including mass attenuation coefficients (general, photoelectric absorption, and scattering), linear attenuation coefficients (μ), half-value layers (HVLs), tenth-value layers (TVLs), mean free paths (MFPs), and radiation protection efficiencies (RPEs), utilizing the Monte Carlo simulation software Geant4 and the WinXCom database across a gamma-ray energy spectrum of 40–150 keV. The study also compared the computational discrepancies among these measurements. Compared to rubber composites doped with single-component fillers, multi-component mixed shielding materials significantly mitigate the shielding deficiencies observed with single-component materials, thereby broadening the γ-ray energy spectrum for which the composites provide effective shielding. Subsequently, the simulation outcomes were juxtaposed with experimental data derived from a 133Ba (80 keV) γ-source. The findings reveal that the simulated results align closely with the experimental observations. When compared to the WinXCom database, the Geant4 software demonstrates superior accuracy in deriving radiation shielding parameters and notably enhances experimental efficiency.
Nerve agents always pose a serious threat to human safety and health as a result of their extremely high toxicity and convenient transport, which has prompted much effort to develop some methods with fast response and high selectivity for detecting nerve agents. Herein, we designed and synthesized two simple rhodamine phenol-based derivatives (RBNP and RBMP). From spectral experiments, we found that RBNP exhibited a significant change of absorption and fluorescence intensity with the nerve agent simulant diethylchlorophosphate (DCP), which could give rise to a fast response within 10 s and high sensitivity with an extremely low detection limit of 1.4 nM in the solution. The sensing mechanism could be attributed to it forming a stable five-membered ring by intramolecular bonding under protonation on the basis of experimental and theoretical calculations. Furthermore, test strips were successfully prepared by immersing TLC plates into the probe RBNP solution and these also achieved a visual system for detecting GB vapor. Therefore, a fast and convenient prospective test method is reported for visually detecting real nerve agents.