This paper presents a new algorithm for the detection of ferroresonance oscillations in medium voltage (MV) power systems. The proposed method is based on an analysis of estimated flux resulting from the voltage in open delta voltage transformer (VT) connection. The testing results proved that the new solution is capable of identifying quickly and reliably ferroresonance oscillations and it does not maloperate during faults. In addition, this method is simple for hardware implementation. The developed solution has been thoroughly tested on simulation runs (from the MATLAB2019b/Simulink program), as well as recorded signals.
In this paper, the analysis and simulation of shunt reactor turn-to-turn faults, as well as the algorithms for their detection, are presented. A simple equivalent circuit of a shunt reactor applicable for a small number of short-circuited turns was developed and applied to simulate such faults. It is shown why the commonly applied differential relays are not able to detect turn-to-turn faults. Then three new algorithms are introduced and their performance is analyzed for simulated internal faults. The proposed methods are based on zero-sequence reactance, negative-sequence reactance, and phase impedance. The sensitivity and security of the presented methods are discussed. The proposed algorithms’ performance has been tested with the signals generated with the use of the MATLAB/Simulink program. The results confirm that the proposed algorithm can effectively improve the detection of turn-to-turn faults. The paper ends with recommendations for the setting of the proposed protection schemes.
Superconducting fault current limiters (SFCL) can be an alternative to conventional devices limiting short-circuit currents in power systems. SFCL use high-temperature superconducting tapes of the second generation (HTS 2G) in SFCL, which, after reaching the characteristic critical current of the tape, go into the resistive state (quenching), limiting the short-circuit current. The critical current determines the moment of activation of the SFCL. Therefore, its value should not change during the operation of the device due to repeated limitation of short-circuit currents. The constancy of the critical current is a prerequisite for proper cooperation with the power system protection devices. Multiple quenching can cause microdamage in the superconducting layers responsible for lowering of the value of the critical current of the HTS tapes. The article presents the research results on the degradation processes of 2G HTS tapes intended for the construction of SFCL due to the action of prospective short-circuit currents with values exceeding the critical current of the tested tapes. The decrease in the value of the critical current of the HTS tape as a result of multiple transitions to the resistive state was investigated. The amount of energy emitted during the test current pulse of 0.2 s duration was determined. The limitation values of the voltage drop on the tape, which does not cause accelerated degradation processes, were defined. The microstructural tests of cross-sections of new HTS tapes subjected to prospective short-circuit currents were performed.
In this paper, superconducting fault current limiter (SFCL) operation in the presence of a long-duration fault is presented. The SFCL device utilizes second-generation high-temperature superconducting (2G HTS) tapes, which exhibit zero resistance under normal operating conditions. When the current exceeds the critical threshold specific to the superconducting tape, then it undergoes a transition to a resistive state—a phenomenon known as quenching. As a consequence, this leads to introducing impedance into the circuit, effectively limiting the magnitude of the fault current. Additionally, this transition dissipates electrical energy as heat within the material. The generated energy corresponds to the product of the voltage drop across the quenched region and the current flowing through it during the fault duration. In specific configurations of the power system, it is expected that the SFCL should limit the fault current for an extended period of time. In such a situation, a certain amount of energy will be generated, and it must be verified that the tape loses its properties or parameters (e.g., lowering the critical current value) or is destroyed. Therefore, experimental tests of the tapes were conducted for various short-circuit current, voltage drop, and short-circuit duration values to assess the effect of the amount of generated energy on the 2G HTS tape. Additionally, recommendations are presented on how to protect the SFCL during long-lasting short circuits.
The electrical protection of power networks with fault contribution from inverter-based power sources imposes new application challenges that have to be dealt with by protection engineers. This paper describes the development of a study case model of an HVDC-MMC link for testing the protection behaviour of connected converter transformers. The paper summarises the implementation and validation of the converter control as well as enhancements to provide Fault Ride-Through capability and fast fault current injection as required by the German Technical Connection Rules for HVDC. The grid code standard requires positive- and negative-sequence reactive current injection in the case of grid faults. A Doubled Decoupled Synchronous Reference Frame Phase Locked Loop (DDSRF-PLL) for Vector Current Control (VCC) is implemented. Additionally, a Fault Detection and Fault Ride-Through Reference Generator with a Current Limitation strategy is introduced. Though these techniques are well described in the literature, the DDSRF is improved for current control stability. The relationship between the parameters of the PLL and the control, as well as the behaviour of the protection system, are demonstrated. Grid faults with large voltage dips pose a significant challenge to the stability of the control system. Nevertheless, it is shown that with the developed model, it is possible to make general statements about the protection behaviour in an inverter-based environment.
Current differential protection, using either phase currents or negative-sequence components, is commonly applied for the sensitive protection of power transformers. However, this method proves insufficient for autotransformers, particularly when their tertiary winding is fully loaded, as demonstrated in this paper. To address this limitation, the authors’ previously proposed negative-sequence integral approach for power transformers has been adapted and evaluated for three-winding autotransformers. The results show that this integral protection offers significantly higher sensitivity than current differential schemes while maintaining security during external faults with current transformer saturation.