Photovoltaics and batteries can be connected to a traction power supply system through a railway power conditioner (RPC) to switch between different control strategies. This can address power quality issues or provide emergency traction for locomotives that unexpectedly lose power and even break through traditional energy barriers in the railway field, achieving a low-carbon power supply for railway energy, and a mutual backup with substations. However, methods to coordinate the control strategies of PV and the battery locomotive traction have not been clearly revealed, nor has the actual stability of the system. In this study, to address the above issues, an emergency power supply scheme is proposed for the first time that utilizes a dual-mode RPC inverter combined with a coordinated control strategy for the PV and battery, achieving the traction of locomotives. In addition, a one-dimensional impedance model was established for the PV system, battery system, locomotive (CRH3), and RPC projected onto the dq coordinate system, and the critical amplitude margin (CAM) was defined to quantitatively analyze the sensitivity and laws of different parameters concerning the low-frequency stability of the system. At the same time, impedance ratios and passive criteria were used to reveal the stability mechanism, and parameter adjustment criteria and design suggestions were put forward. Finally, the feasibility of the emergency power supply scheme of the “PV–battery locomotive network” coupling system and the correctness of the low-frequency stability study were verified using the Starsim semi-physical experiment platform.
To reduce the current harmonics on the input side of a multi-pulse rectifier, this paper proposes a low harmonic current source series multi-pulse rectifier based on an auxiliary passive injection circuit at the DC side. The rectifier only needs to add an auxiliary passive injection circuit on the DC side of the series 12-pulse rectifier, which can change its AC input voltage from 12-step waves to 24-step waves. We analyzed the working mode of the rectifier, optimized the optimal turn ratio of the injection transformer from the perspective of minimizing the total harmonic distortion (THD) value of the input voltage on the AC side, and analyzed the diode open circuit fault in the auxiliary passive injection circuit. Test verification shows that, after using the passive harmonic injection circuit, the THD value of the input voltage of the AC side of the rectifier is reduced from 14.03% to 4.86%. The THD value of the input current is reduced from 5.30% to 2.16%. The input power factor has been increased from 98.86% to 99.83%, and the power quality has been improved.
High-speed railways generate a large amount of regenerative braking energy during operation but this energy is not utilized efficiently. In order to realize the recycling of regenerative braking energy of high-speed railways, the hybrid energy storage type railway power conditioner (RPC) system is proposed. The working principle and the control strategy of the system are studied. The energy management strategy consisting of a hybrid energy storage system charging and discharging strategy and variational modal decomposition (VMD) power allocation strategy is proposed. Three system operation modes are proposed: the power of the hybrid energy storage system is decomposed by VMD and an interrelationship number is proposed to determine the lithium battery and supercapacitor power. The hardware-in-the-loop test experiments are conducted by the StarSim power electronics small-step real-time simulator from Modeling Tech and the validation analysis is carried out on MATLAB/Simulink with the actual measurement data of a traction substation on the Lanzhou–Xinjiang line. The results verify that the proposed strategy can effectively recycle the regenerative braking energy, realize the peak-shaving effect on the load, and reduce the energy consumption of the train.
To solve the problem of the large size of traditional industrial frequency phase-shift transformers and the harmonic distortion of multi-pulse wave rectifier systems, this paper proposes a three-stage shunt zigzag power electronic phase-shift transformer based on a double-tap multi-pulse wave rectifier, which combines the power factor correction (PFC) converter with the voltage-type SPWM inverter circuit to form a power electronic converter to realize the frequency boost and power factor correction. Through AC–DC–AC conversion, the frequency of the three-phase AC input voltage is increased, the number of core and coil turns in the transformer is reduced to reduce the size of the phase-shifter transformer, a zigzag structure of the phase-shifter transformer is used to solve the unbalanced distribution of current between the diode bridges, and a passive harmonic suppression method on the DC side is used to generate a loop current by using a group of single-phase rectifier bridges to regulate the input line current of the phase-shifter transformer. The phase-shifted voltage is input into two three-phase diode rectifier bridges to rectify and supply power to the load. Simulation and semi-physical test results show that the proposed method reduces the total harmonic distortion (THD) value of the input current of the phase-shifted transformer to 7.17%, and the THD value of the grid-side input current is further reduced to 2.49%, which meets the harmonic standard and realizes the purpose of power factor correction as well as being more suitable for high-power applications.
Active control of pantograph is an effective method to improve the current received quality in electrified railway systems. To alleviate the negative impact of time delay in pantograph actuator, a Controlled Auto-Regressive Integrated Moving Average (CARIMA) model was designed for pantograph active control. In conjunction with the Euler-Bernoulli catenary model, an improved generalized predictive control (IGPC) algorithm was proposed, and its stability was analyzed. Then, the control performance was verified and discussed through testing. Subsequently, the effects of external disturbances and time delay on control performance were discussed. The results indicate that the proposed controller with a larger control gain, exhibits better performance in reducing fluctuation in contact force between pantograph and catenary, despite being affected by external disturbance and actuator time delay, it still shows significant control performance.