ma xiping

Dr. ma xiping


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
MXma xiping
ma xiping
WZWenxi Zhen
Wenxi Zhen
HRHaodong Ren
Haodong Ren
GZGuangru Zhang
Guangru Zhang
KZKai Zhang
Kai Zhang
HDHaiying Dong
Haiying Dong
To address the issues arising from the integration of a high proportion of distributed generation (DG) into the distribution network, which has led to the transition from traditional single-source to multi-source distribution systems, resulting in increased complexity of the distribution network topology and difficulties in fault localization, this paper proposes a fault localization method based on graph convolutional networks (GCNs) for distribution networks with a high proportion of distributed generation. By abstracting busbars and lines into graph structure nodes and edges, GCN captures spatial coupling relationships between nodes, using key electrical quantities such as node voltage magnitude, current magnitude, power, and phase angle as input features to construct a fault localization model. A multi-type fault dataset is generated using the Matpower toolbox, and model training is evaluated using K-fold cross-validation. The training process is optimized through early stopping mechanisms and learning rate scheduling. Simulations are conducted based on the IEEE 33-node distribution network benchmark, with photovoltaic generation, wind generation, and energy storage systems connected at specific nodes, validating the model’s fault localization capability under various fault types (single-phase ground fault, phase-to-phase short circuit, and line open circuit). Experimental results demonstrate that the proposed model can effectively locate fault nodes in complex distribution networks with high DG integration, achieving an accuracy of 98.5% and an AUC value of 0.9997. It still shows strong robustness in noisy environments and is significantly higher than convolutional neural networks and other methods in terms of model localization accuracy, training time, F1 score, AUC value, and single fault detection inference time, which has good potential for practical application.

16 July 2022 in Energies
Verified
Journal Article
Open access
PDF file
YLYuying Li
Yuying Li
MXma xiping
ma xiping
LCliang chen
liang chen
YLYaxin Li
Yaxin Li
ZCZhou Cai
Zhou Cai
TJTong Jiang
Tong Jiang
In order to find the causes of statistical line loss abnormalities and propose better loss reduction strategies, it is necessary to improve the accuracy of theoretical line loss calculations. Since Distributed Generation (DG) access to the distribution network causes variability of power flow in the distribution network within a short period, the error of the traditional line loss calculation method increases. For the line loss calculation of medium-voltage distribution networks containing DGs with high-density collection data, a continuous line loss calculation method for the distribution network was proposed, aiming at improving the accuracy compared with the traditional line loss calculation method. The proposed method makes full use of the high-density collection data on the dispatch side and DG side, distributing the supply power to each load node by power to calculate real-time power flow, thus obtaining a more credible line loss value. The effectiveness and accuracy of the proposed method were verified in the IEEE 17-node distribution system.

3 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
HLHongwei Li
Hongwei Li
LXLi Xingmin
Li Xingmin
SCSiyu Chen
Siyu Chen
Shuaibing LiShuaibing Li
Shuaibing Li
YKYongqiang Kang
Yongqiang Kang
MXma xiping
ma xiping
To realize the low-carbon operation of integrated energy systems (IESs), this paper proposes a low-carbon optimal scheduling method. First of all, considering the integrated demand response of price-based electricity and heating, an economic scheduling model of the IES integrated demand response based on chance-constrained programming is proposed to minimize the integrated operating cost in an uncertain environment. Through the comprehensive demand response model, the impact of the demand response ratio on the operating economy of the IES is explored. Afterward, the carbon emission index is introduced, and gas turbines and energy storage devices are used as the actuators of multi-energy coupling to further explore the potential interactions between the coupling capacities of various heterogeneous energy sources and carbon emissions. Finally, the original uncertainty model is transformed into a mixed-integer linear-programming model and solved using sequence operation theory and the linearization method. The results show that the operating economy of the IES is improved by coordinating the uncertainty of the integrated demand response and renewable energy. In addition, the tradeoff between the working economy and reliability of the EIS can be balanced via the setting of an appropriate confidence level for the opportunity constraints.

6 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
LCliang chen
liang chen
CCChen Chang
Chen Chang
WWWeizhou Wang
Weizhou Wang
MXma xiping
ma xiping
YLYuying Li
Yuying Li
TJTong Jiang
Tong Jiang
Data collection is more difficult in distribution network than transmission networks since the structure of distribution networks is more complex. As a result, data could be partly abnormal or missing, which cannot completely describe the operation status of distribution network. In addition, access of distributed generation (DG) to distribution network further aggravates the variability of power flow in distribution network. The traditional deterministic line loss calculation method has some limitations in accurately estimating the line loss of distribution network with DG. A line loss interval calculation method based on power flow calculation and linear optimization is proposed, considering abnormal data collection and distribution network power flow variability. The linear optimization model is established according to sensitivity of line loss to the injected power and sensitivity of transmission power of first branch to the injected power. Introducing the scheduling information into the optimization model, a reliable line loss fluctuation interval can be obtained which actual line loss locates. The effectiveness of the proposed algorithm is verified in IEEE 33-bus distribution network system.

11 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
MXma xiping
ma xiping
RJRong Jia
Rong Jia
LCliang chen
liang chen
HDHaodong Du
Haodong Du
XDXiaoyang Dong
Xiaoyang Dong
MDMan Ding
Man Ding
One of the primary causes of additional losses in dry-type distribution transformers is harmonic disturbances in the distribution network. It is critical to investigate the change law of trans-former losses under harmonic conditions. The effect of harmonics on transformer core losses and winding losses is first investigated in this paper. The field-circuit coupling method is then used to create a finite element model of a three-phase phase dry type distribution transformer. Finally, the relationship between core loss and harmonic voltage, winding loss and harmonic current is calculated and analyzed for each harmonic frequency. The AC resistance factor model is found to be more accurate than the conventional model in calculating transformer harmonic winding losses. This paper’s findings have significant theoretical implications for the analysis of harmonic losses and loss reduction in distribution networks.

28 August 2024 in Electronics
Verified
Journal Article
Open access
PDF file
MXma xiping
ma xiping
RJRong Jia
Rong Jia
LCliang chen
liang chen
RXRui Xu
Rui Xu
In view of the current problem of insufficient consideration being taken of the effect of voltage control and the adjustment cost in the voltage control strategy of distribution networks containing photovoltaic (PV) and energy storage (ES), a multi-stage optimization control method considering grouping collaboration is proposed. Firstly, the mechanism by which the access of the PV and ES to the distribution network impacts the node voltage is explored. Then, the unit regulation cost of a photovoltaic inverter and energy storage power is studied. On this basis, the voltage–cost sensitivity is proposed based on the traditional node power–node voltage sensitivity. According to the differences between each group of regulation resources, a multi-stage voltage over-run control strategy based on grouping cooperation is proposed. Finally, the improved 33-node model is taken as an example to verify the correctness and effectiveness of the proposed method.