Jaime Octavio Guerra-Pulido

Dr. Jaime Octavio Guerra-Pulido


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
MMMario Nicola Mazziotta
Mario Nicola Mazziotta
AAA.R. Altamura
A.R. Altamura
LCLiliana Congedo
Liliana Congedo
GRG. De Robertis
G. De Robertis
AMAntonio D Mauro
Antonio D Mauro
GVGiacomo Volpe
Giacomo Volpe
A dedicated R&D is ongoing for the charged particle identification system of the ALICE 3 experiment proposed for the LHC Run 5 and beyond. One of the subsystems for the high-energy charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector. The possibility of integrating Cherenkov-based charged particle timing measurements is currently under study. The proposed system is based on a proximity-focusing RICH configuration including an aerogel radiator separated from a SiPM array layer by an expansion gap. A thin high-refractive index window of transparent material, acting as a second Cherenkov radiator, is glued on the SiPM array to enable time-of-flight measurements of charged particles by exploiting the yield of Cherenkov photons in the thin window. We assembled a small-scale prototype instrumented with different Hamamatsu SiPM array sensors with pitches ranging from 1 to 3 mm, readout by custom boards equipped with the front-end Petiroc 2A ASICs to measure charges and times. The primary Cherenkov radiator consisted of a 2 cm thick aerogel tile, while various window materials, including SiO2 and MgF2, were used as secondary Cherenkov radiators. The prototype was successfully tested in a campaign at the CERN PS T10 beam line with pions and protons. This paper summarizes the results achieved in the 2023 test beam campaign.

26 May 2025 in The European Physical Journal C
Verified
Journal Article
Open access
PDF file
AAA. R. Altamura
A. R. Altamura
LCLiliana Congedo
Liliana Congedo
GRG. De Robertis
G. De Robertis
DBD. Di Bari
D. Di Bari
AMAntonio D Mauro
Antonio D Mauro
GVGiacomo Volpe
Giacomo Volpe
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Runs 5 and beyond. In this context, a key subsystem for high-energy charged particle identification will be a proximity-focusing ring-imaging Cherenkov detector using aerogel as radiator and silicon photomultipliers (SiPMs) as photon sensors. We assembled a small-scale prototype instrumented with Hamamatsu S13352 and S13361-3075AE-08 SiPM arrays, readout by custom boards equipped with front-end Petiroc 2A ASICs. The Cherenkov radiator consisted of a 2 cm thick hydrophobic aerogel tile with a refractive index of 1.03 separated from the SiPM plane by a 23 cm expansion gap. The prototype was successfully tested in a campaign at the CERN PS T10 beam line with the goal of validating the design bRICH specifications in terms to achieve the target separation power. We measured a single photon angular resolution of 3.8 mrad at the Cherenkov angle saturation value of 242 mrad, as well as the expected scaling of the angular resolution with the increasing number of detected photons. We also studied the contribution of uncorrelated and correlated background sources with respect to the signal and proved the effectiveness of time matching between charged tracks and photon hits to achieve efficient suppression of the SiPM dark count rate background. In this paper, the detector concept, the description of the tested prototype layout and the main beam test results are reported.

3 October 2018 in Computer Applications in Engineering Education
Verified
Journal Article
Closed access
PDF file
JGJaime Octavio Guerra-Pulido
Jaime Octavio Guerra-Pulido

10 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AAAlexis Aguilar-Arevalo
Alexis Aguilar-Arevalo
XBXavier Bertou
Xavier Bertou
CCCarles Canet
Carles Canet
MCMiguel Angel Cruz-Pérez
Miguel Angel Cruz-Pérez
ADAlexander Deisting
Alexander Deisting
JWJoseph Walding
Joseph Walding
This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g., 210Pb, producing γ-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of X-rays and low energy γ-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2%. The Neo sCMOS is not sensitive to X-rays with energies below ∼10 keV. The smallest detectable rate is 40±3mHz, corresponding to an incident activity on the chip of 7±4Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08(2)% (0.0011(2)%) at 26.3keV (59.5keV). Taking calorimetric information into account we measure a minimal detectable rate of 4±1mHz (1.5±1mHz) for 26.3keV (59.5keV) γ-rays, which corresponds to an incident activity of 1.0±6Bq (57±33Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a γ- and X-ray detector with sensitivity at the few to 100 ppb level for 210Pb in a sample.

7 January 2025 in Communications Engineering
Verified
Journal Article
Open access
PDF file
ADAdriana Dias
Adriana Dias
MAM. Alvarez
M. Alvarez
YGY. Gándola
Y. Gándola
ADAlexander Deisting
Alexander Deisting
EPE. Alba Posse
E. Alba Posse
MMM. L. Vazquez Miranda
M. L. Vazquez Miranda
This paper reports the design of a biosensor for sensitive, low-cost measurement of lead in drinking water. The biosensor uses a genetically-modified strain of Escherichia coli, which serves as both signal amplifier and reporter of lead in water, measured via colour change. We developed the PlomBOX measurement platform to image this colour change and we demonstrate its capability to detect concentrations as low as the World Health Organisation upper limit for drinking water of 10 ppb. Our approach does not require expensive infrastructure or expert operators, and its automated sensing, detection and result visualisation platform is user-friendly and robust compared to existing lead biosensors—critical features to enable measurement by non-experts at the point of use.

14 July 2011 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JGJaime Octavio Guerra-Pulido
Jaime Octavio Guerra-Pulido
PPPablo Perez
Pablo Perez
Phase velocity of a surface acoustic wave (SAW) varies when the electric field associated with the wave interacts with a conductive material located above the propagation plane. In this paper, we propose a general method to approximate the scattering matrix when the conductive structure has a specific geometry. This structure has reflective properties of SAW. As an example, we considered a previously reported SAW-MEMS microaccelerometer which mainly consists of a slotted beam. By applying this method, we obtained the relationship between acceleration and the reflection and transmission coefficients. The dynamic of the slotted beam was studied using the finite element method (FEM). It was observed that relatively small variations in the size of the microstructure could cause significant changes in the reflection and transmission coefficients. We also show that the slotted beam acts as an acoustic wave bandpass filter, and its response is similar to that of reflective gratings, but with linear phase.