Ladan Eslamian

Prof. Dr. Ladan Eslamian

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
LELadan Eslamian
Ladan Eslamian
Ali Borzabadi-FarahaniAli Borzabadi-Farahani
Ali Borzabadi-Farahani
SKShahedeh Karimi
Shahedeh Karimi
SSSepideh Saadat
Sepideh Saadat
MBMohammad Reza Badiee
Mohammad Reza Badiee
This study evaluated the effect of incorporating silver nanoparticles (AgNPs) into conventional orthodontic adhesive on its antibacterial activity and the shear bond strength (SBS) to stainless steel orthodontic brackets. Thirty-four extracted premolars were randomly allocated into two groups (n = 17). Orthodontic adhesive (Transbond XT, 3M Unitek) was blended with AgNPs (50 nm, 0.3% w/w) to form a nano-adhesive. In order to bond stainless steel twin brackets (0.022-inch, American Orthodontics), Transbond XT (n = 17) and nano-adhesive (n = 17) were used in each group, respectively, after acid etching (37% phosphoric acid, 30 s) and rinsing with water (15 s). SBS and the adhesive remnant index (ARI) scores were recorded. Antibacterial activity against Streptococcus mutans in both groups after 24 h and 30 days was assessed (Disc agar diffusion test) and the inhibition zone diameter around each specimen was measured and recorded. Adding AgNPs significantly (p = 0.009) reduced the mean (SD) SBS in the nano-adhesive group [10.51(7.15) MPa] compared to Transbond XT [17.72(10.55) MPa]. The ARI scores on the Transbond XT and nano-adhesive showed no statistically significant difference (p = 0.322). Nano-adhesive with AgNPs showed significant antibacterial activity against Streptococcus mutans at 24 h and 30 days (p < 0.001). In both groups, no significant decline in the zones of inhibition was detected after 30 days (p = 0.907). The findings suggest that SBS decreased after incorporation of AgNPs [0.3% (w/w)], but was still above the recommended SBS of 5.9–7.8 MPa. The nano-adhesive showed significant antibacterial activity which did not change much after 30 days.

1 May 2011 in Australasian Orthodontic Journal
Verified
Journal Article
Open access
PDF file
LELadan Eslamian
Ladan Eslamian
Ali Borzabadi-FarahaniAli Borzabadi-Farahani
Ali Borzabadi-Farahani
NMNasin Mousavi
Nasin Mousavi
AGAmir Ghasemi
Amir Ghasemi
Objective: To compare the shear bond strengths (SBS) of stainless steel brackets bonded to artificially-aged composite restorations after different surface treatments. Methods: Forty-five premolar teeth were restored with a nano-hybrid composite (Tetric EvoCeram), stored in deionised water for one week and randomly divided into three equal groups: Group I, the restorations were exposed to 5 per cent hydrofluoric acid for 60 seconds; Group II, the restorations were abraded with a micro-etcher (50 μm alumina particles); Group III, the restorations were roughened with a coarse diamond bur. Similar premolar brackets were bonded to each restoration using the same resin adhesive and the specimens were then cycled in deionised water between 5 °C and 55 °C (500 cycles). The shear bond strengths were determined with a universal testing machine at a crosshead speed of 1 mm/min. The teeth and brackets were examined under a stereomicroscope and the adhesive remnants on the teeth scored with the adhesive remnant index (ARI). Results: Specimens treated with the diamond bur had a significantly higher SBS (Mean: 18.45 ± 3.82 MPa) than the group treated with hydrofluoric acid (Mean: 12.85 ± 5.20 MPa). The mean SBS difference between the air-abrasion (Mean: 15.36 ± 4.92 MPa) and hydrofluoric acid groups was not significant. High ARI scores occurred following abrasion with a diamond bur (100 per cent) and micro-etcher (80 per cent). In approximately two thirds of the teeth no adhesive was left on the restoration after surface treatment with hydofluoric acid. Conclusion: Surface treatment with a diamond bur resulted in a high bond strength between stainless steel brackets and artificially-aged composite restorations and was considered to be a safe and effective method of surface treatment. Most of the adhesive remained on the tooth following surface treatment with either the micro-etcher or the diamond bur.

4 February 2009 in European Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
LELadan Eslamian
Ladan Eslamian
AGAmir Ghassemi
Amir Ghassemi
FAFariborz Amini
Fariborz Amini
AJAlireza Jafari
Alireza Jafari
MAMona Afrand
Mona Afrand
The purpose of this in vitro study was to determine a safe and efficient method for bonding brackets to resin composite (RC), permitting the brackets to tolerate shear forces and allowing removal without causing surface damage to the aesthetic restoration. The shear bond strength (SBS) of 60 brackets bonded to silanated and non-silanated RC surfaces were compared. A Bis-GMA containing orthodontic adhesive system was used to bond stainless steel upper lateral incisor brackets to 60 composite discs, half of which had surface treatment with a silane coupling agent. SBS testing was performed with an Instron universal testing machine. After debond, the bracket base and corresponding RC discs were examined under a stereomicroscope and analyzed using the Adhesive Remnant Index (ARI). Non-parametric tests (Mann–Whitney U) indicated significant differences between the two groups (P < 0.009). Lower bond strengths were found for the silanated group implying that silane agents may be an unnecessary step. However, both groups had a clinically acceptable mean SBS [silanated group = 13.1 megapascals (Mpa), non-silanated group = 19.4 MPa]. Bond failure occurred at the bracket–adhesive interface in both groups. There would appear to be no advantage in using a silane agent when bonding metal orthodontic brackets to filled RCs.

25 September 2006 in European Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
LELadan Eslamian
Ladan Eslamian
ALAmir Peyman Leilazpour
Amir Peyman Leilazpour
The aims of this study were to determine the location and movements of the tongue on the palate during pronunciation of Persian consonants and selected words in subjects with and without a tongue thrust (TT). Ten patients with a TT and 10 control subjects, 9-13 years of age, matched for age, gender, ethnicity, type and severity of malocclusion, with no history of orthodontic treatment, surgery, or systemic disease were selected. Maxillary alginate impressions were taken to construct upper removable appliances with 12 electrodes. Fine wires connected the electrodes to a specially designed electropalatovision (EPU) device. The removable appliance was inserted in the upper arch and then the Persian consonants and some selected words were pronounced by both groups. An electromechanical marker was included on each electrode which showed the tongue movements on the palate. Tongue movements, the quantity of the tongue contacts, and the location of the tongue were compared using t - and Chi-square tests. In the TT group, the tongue had more contact with the palate on six electrodes ( P < 0.001). When pronouncing the consonants, the tongue made contact anteriorly on the palate in the TT group. The quantity of tongue contacts with the palate was similar in both groups. During pronunciation of selected words, the contact points of the tongue to the palate were similar in both groups.

1 January 2024 in Australasian Orthodontic Journal
Verified
Journal Article
Open access
PDF file
Ali Borzabadi-FarahaniAli Borzabadi-Farahani
Ali Borzabadi-Farahani
HOHatice Kübra Olkun
Hatice Kübra Olkun
LELadan Eslamian
Ladan Eslamian
FEFaezeh Eslamipour
Faezeh Eslamipour
Purpose: The present study aimed to explore the malocclusion trends, sagittal skeletal discrepancies, and the index of orthognathic functional treatment need (IOFTN) scores in a sample of Iranian and Turkish orthognathic patients. Methods: Four hundred and three orthognathic patients were retrospectively examined (203 Iranian/200 Turkish, 229 females/174 males, aged between 16 and 50 years). The following variables were recorded: malocclusion type (incisor-based), overjet, sagittal skeletal relationship (ANB angle) and IOFTN scores. The sagittal skeletal relationships and malocclusion patterns of the orthognathic patients were statistically examined using Chi-square tests and further explored graphically. The relationship between the IOFTN scores and overjet, as well as the sagittal skeletal discrepancies (ANB angle) was evaluated using box plots and at the 95% confidence interval (CI) in different IOFTN treatment categories (1–3,4,5). The characteristics of a subgroup sample of orthognathic patients and previous studies that identified with low IOFTN scores (1–3) were also explored. Results: Class III malocclusions and Class III skeletal patterns were the most prevalent (62.3%), forming 69% and 55.7% of the Turkish and Iranian samples, respectively. Turkish and Iranian samples had more Class III [Mean (SD) ANB angle = -1.24° (4.75°)] and Class II cases [Mean (SD) ANB angle=1.06° (5.63°)], respectively. The mean overjet and reverse overjet for Class II and III malocclusions were 6.96 mm (95% CI, 6.40–7.53 mm) and 3.26 mm (95% CI, 2.87–3.65 mm), respectively. The mean ANB angle for Class II and III malocclusions was 6.64° (95% CI, 6.15°–7.13°) and -3.57° (95% CI, -3.92° to -3.21°), respectively. IOFTN scores of 4 or 5 were identified in 93.8% of the sample. Patients with low IOFTN scores (<4) presented with a nearly normal overjet (mean = 3.19 mm, 95% CI, 2.62-3.76 mm, range = 1–5 mm), accompanied by a wide range of ANB angles [mean (SD)=3.44° (3.86°), range = -4° to 9°] Conclusions: The findings at the 95% CI for overjet and the ANB angle can be used as identifiers for patients who would benefit from orthognathic surgery. Analysing patients with a low IOFTN score, particularly with scores of 3.3, 3.10, 2.8, and 1.14, revealed that IOFTN could be used in conjunction with a clinical examination plus diagnostic imaging to facilitate the identification of orthognathic surgery patients.

1 December 2019 in Dental Press Journal of Orthodontics
Verified
Journal Article
Open access
PDF file
LELadan Eslamian
Ladan Eslamian
MTMaryam Torshabi
Maryam Torshabi
SMSaeed Reza Motamedian
Saeed Reza Motamedian
YHYasamin Babaee Hemmati
Yasamin Babaee Hemmati
SMSeyed Alireza Mortazavi
Seyed Alireza Mortazavi
Introduction: Pain related to orthodontic tooth movement is common and cause dissatisfaction and discomfort. Objective: The present study aimed to compare the efficacy of naproxen patches in pain control during orthodontic tooth separation, by means of visual analogue scale (VAS) and interleukin 1β (IL-1β) levels in gingival crevicular fluid (GCF). Methods: In this split-mouth triple-blind clinical trial, with 40 patients following separation, 5% naproxen or placebo patches were randomly placed on the upper right or left first molars every 8 hours. Pain intensity scores were determined after 2 and 6 hours, sleep time, 24 hours, days 2, 3 and 7 by the patients using a 100-mm VAS ruler. IL-1β levels in GCF were evaluated by ELISA at baseline, 1 and 24 hours and 7 days. Paired samples t-tests and two-way repeated measures ANOVA analysis of variance with a significance level of 0.05 were applied. Results: A total number of 30 patients (13 males and 17 females) finished the trial. Significant differences were found in pain scores (p< 0.0001) and IL-1β levels (p= 0.047) between naproxen and placebo groups. Lower pain scores were reported for the patients using naproxen patches at all time points, except 1 hour after separation. IL-1β levels were lower for the patients using naproxen patches only 1 hour after separation (p= 0.047). The peak of pain scores and IL-1β levels were calculated at 24 hours. Conclusion: In the light of VAS scores and IL-1β levels, naproxen patches reduced the pain caused by separator placement.