The aim of this study was to test the hypothesis that there is no difference in salivary metal ion content between subjects with fixed orthodontic appliances and their same-gender sister or brother without any orthodontic appliance. This retrospective study was carried out on 28 subjects (16 females and 12 males) who had undergone fixed orthodontic therapy for a duration of 12–18 months. In order to limit the effects of dietary and hygiene habits on salivary metal ion concentration, a same-gender brother or sister (total of 28 subjects) was selected as a control. Approximately 5 ml of saliva was collected from each subject, and the samples were analysed using an atomic absorption spectrophotometer. The detection limit of the method for sample solutions was 1 ng/ml. Since some variables were not normally distributed, non-parametric tests (Mann–Whitney U and Wilcoxon W ) were used for statistical analysis. The mean salivary nickel (Ni) content in subjects with and without a fixed orthodontic appliance was 18.5 ± 13.1 and 11.9 ± 11.4 ng/ml, respectively. A statistically significant difference (P < 0.035) was found between the two groups. The mean salivary chromium (Cr) ion level recorded was 2.6 ± 1.6 ng/ml in the study group and 2.2 ± 1.6 ng/ml in the control group. The difference, however, was statistically insignificant. Within the limits of this in vivo study, it can be concluded that the presence of fixed orthodontic appliances leads to an increased concentration of metal ions in salivary secretions.
4 February 2009 in European Journal of Orthodontics
The purpose of this in vitro study was to determine a safe and efficient method for bonding brackets to resin composite (RC), permitting the brackets to tolerate shear forces and allowing removal without causing surface damage to the aesthetic restoration. The shear bond strength (SBS) of 60 brackets bonded to silanated and non-silanated RC surfaces were compared. A Bis-GMA containing orthodontic adhesive system was used to bond stainless steel upper lateral incisor brackets to 60 composite discs, half of which had surface treatment with a silane coupling agent. SBS testing was performed with an Instron universal testing machine. After debond, the bracket base and corresponding RC discs were examined under a stereomicroscope and analyzed using the Adhesive Remnant Index (ARI). Non-parametric tests (Mann–Whitney U) indicated significant differences between the two groups (P < 0.009). Lower bond strengths were found for the silanated group implying that silane agents may be an unnecessary step. However, both groups had a clinically acceptable mean SBS [silanated group = 13.1 megapascals (Mpa), non-silanated group = 19.4 MPa]. Bond failure occurred at the bracket–adhesive interface in both groups. There would appear to be no advantage in using a silane agent when bonding metal orthodontic brackets to filled RCs.
To investigate the associations between both unilateral/bilateral palatal impactions of the maxillary canine and a long list of various dentoalveolar anatomical measurements and parameters. This case-control study was performed on CBCTs of 3 groups of 23 subjects each (control, unilateral impaction, bilateral impaction, n = 138 hemimaxillae in 69 patients). Examined were the mesiodistal and buccolingual widths of the 1–6 teeth on the right and left sides, all their roots’ lengths, maxillary arch widths on the axial plane at the basal bone and the alveolar bone levels, at the distances 5, 10, 20, 30, and 40 mm from the most anterior point, and maxillary arch circumferences. Moreover, primary canine retention was assessed as well. The groups were compared using chi-square, t-test, ANOVA, and Tukey tests (α = 0.05). Significant comparisons (P < 0.05) included: At the basal bone level, the arch width of the most anterior section was smaller in the control group compared to the unilateral impaction group only, while interestingly at the alveolar bone level, it was larger in control group compared only to bilateral impaction cases at the most anterior segment. First molar roots were longer in bilateral canine impaction cases compared to control. The buccolingual sizes of premolars/first molar was smaller in control compared to canine impaction. The 5-to-5 arch circumference was smaller in bilateral impaction cases compared the control or unilateral impaction cases (P < 0.05). Several dentoalveolar variables were linked to canine impaction.
Molar movement control is a fundamental aspect of orthodontic treatment, particularly in managing anchorage and achieving desired occlusal outcomes. The transpalatal arch (TPA) is a commonly used passive or active appliance designed to provide anchorage reinforcement and facilitate specific molar movements. Despite its widespread application, there is limited consensus regarding its quantitative effectiveness. This systematic review and meta-analysis assesses the effectiveness of the TPA in molar movement during orthodontic treatment. An extensive search of major electronic databases was conducted up to the year 2023 to identify studies evaluating the application of the TPA in molar movement. Data regarding study design, participant characteristics, types of TPA used, and numerical outcomes related to molar displacement were systematically extracted. For each outcome, point estimates and corresponding 95% confidence intervals were computed to assess pre- and post-treatment changes. Fourteen studies underwent detailed qualitative synthesis, with 2 classified as low risk, 7 with some concerns, and 5 as high risk of bias. Nine studies were included in the meta-analysis. The pooled change in mesial movement U6-PTV (mm) for the TPA group was 2.73 (95% CI: 1.90-3.50), vertical movement U6-PP (mm) was 1.24 (95% CI: 0.96-1.52), vertical movement U6-FH (mm) was 1.34 (95% CI: 0.36-2.32), and mesial tipping U6-FH (°) was 2.94 (95% CI: 1.51-4.37). This review underscores the TPA's versatility and effectiveness as an anchorage device. Evaluating TPA's full range of applications, beyond comparisons with skeletal devices, is crucial. Future research should incorporate three-dimensional digital models and consider pubertal growth stages for more accurate assessments.