This study was conducted as part of the Joint Crediting Mechanism (JCM) of the Japanese Ministry of Economy, Trade and Industry, and the Ministry of the Environment project’s preparation in Vietnam. Samples were taken from hot and cold water supplies from guest rooms’ faucets in 12 hotels in Hanoi city, Vietnam, and 13 hotels in Japan for comparison. A simple water quality measurement and determination of Legionella was carried out. The results showed that residual effective chlorine—which guarantees bactericidal properties—was not detected in tap water supplied in hotel rooms in Vietnam, and nitrite (an indicator of water pollution) was detected in 40% of buildings. In the hotels in Japan, the prescribed residual chlorine concentration met the prescribed levels, and nitrite was not detected. Additionally, while there was no Legionella detected in the Japanese cases, it was detected in most of the Vietnamese hotels, which were found to manage the hot water storage tank at low temperatures of 40–50 °C. It was found that there were deficiencies in cold and hot water supply quality, and that there was no effective system in place for building operation maintenance and management.
The purpose of this study was to construct a scheme that makes it possible to compare the relationship between water usage, satisfaction, and physical properties in three countries. The physical properties of the shower were measured using physical properties testing apparatus of water-saving standard or scheme for showerheads issued in several water-saving countries and data for users satisfaction evaluation was acquired through bathing experiments. In this paper, we analyzed the result from Taiwanese and Vietnamese individuals to compare them to of Japanese subjects analyzed in the previous study. We compared the physical properties of showers assessed low in satisfaction by Taiwanese, Vietnamese and Japanese subjects. It was assumed that spray pattern tends to decrease satisfaction when the water volume ratio within 100 mm and 150 mm of a measuring device is located a 450 mm distance from the showerhead is low, and that, because all three countries showed the same value, it was imagined that there were no differences in the water volume ratio of high-satisfaction showerheads among three countries. On the other hand, the values of Spray Force-per-Hole, Temperature Drop, and Spray Angle were different among three countries. We speculated that these differences are affected respectively by ethnic differences in pain tolerance, thermoregulatory response and bathing habit.
In a previous study, we showed that widespread adoption of water-saving equipment had the potential to reduce CO2 emissions by 1% in Japan. The usage of already diffused equipment was used as an evaluation baseline. This was an evaluation model of developed countries. In order to evaluate the potential benefits of water-saving in developing countries, it is necessary to set the baseline, as cities in developing countries are expected to have the necessary infrastructure in place in the near future. In this paper, the potential for reducing CO2 emissions by water saving in Vietnam was evaluated. Based on the development of water infrastructure, and envisioning a society in which the latest high-efficiency flush toilet bowls and showers installed in Hanoi and Ho Chi Minh City are used in all Vietnamese houses as a near future baseline, we evaluated the potential reduction when a water-saving project is implemented. Under these conditions, an 8.8% reduction in CO2 emissions in Vietnam would be achieved by the widespread adoption of water-saving equipment. Following the recognition of the large environmental contribution potential of water saving, a water-saving project has been planned for implementation in Vietnam in the near future.
Water saving is a key issue in rapidly developing countries, such as Vietnam, that face various water resource management challenges. This study investigated water-use patterns in a hotel in Ho Chi Minh City in Vietnam. It aimed to quantify the efficiency of water-saving devices through modeling toilet and shower usage patterns, including water consumption. The shift in hourly consumption of cold and hot water was also identified. Analysis revealed that, on average, a full toilet flush occurs 3.3 times/day, a half flush 3.0 times/day, water consumption due to shower usage is 48.1 L/day, showering time is 7.3 min/day and the shower water temperature is 37.7 °C. Shifting levels of hot and cold water use revealed high activity in the morning time and that there are two peaks, occurring in the morning and at night.
To investigate the effect of the COVID-19 (coronavirus) pandemic on residential water use behavior in Japan, we conducted a web-based survey of 1310 people throughout Japan in March 2021, one year after the initial spread of coronavirus. The survey was designed to provide an average picture of Japan. The survey revealed that the time respondents spent at home increased during the pandemic for both men and women in all age groups by an average of 1 h, an increase of 9%. Changes in water use behavior increased almost in proportion to the increase in time spent at home, except for the frequency of defecation, which was limited to once a day. The amount of time spent in the washroom increased by 13%, an increase of more than 1.4 times the increase in the amount of time spent at home. The additional 40% increase could be considered an effect of the awareness of disease prevention. The coronavirus pandemic is expected to end in the near future. In Japan, the pandemic has led to a strong push for the reform of work styles. Therefore, even in a post-coronavirus-pandemic society, changes in work styles may normalize the increased time spent at home and the proportional increase in water use. However, because the change in water use behavior caused by quarantine awareness is a result of the fear of coronavirus infection, it is possible that water use will gradually return to pre-pandemic levels once the source of the fear is removed. To reflect the changes in water use behavior in the design of facilities in the post-coronavirus-pandemic society, it is necessary to continue this survey even once the pandemic has ended.
In Vietnam, the rapid expansion of cities is exceeding the supply capacity for water and electricity, and restrictions on water supply and blackouts occur on a daily basis. In this study, the authors examined whether water-saving equipment could solve these problems. This paper focused on toilet bowls that consumed a large amount of water, and on showers for which heat consumption was high. In Vietnam, the main heat source for showers is the electric water heater, typically having a power consumption of 2500–4500 W. Although the current diffusion rate of such water heaters is just 13%, their use will spread widely in the future. These heaters have already placed a peak load on electricity consumption in winter when a large amount of energy is consumed for heating water, and they will become a significant factor in blackout risks as their use becomes commonplace nationwide. It is clear that the introduction of water-saving showers will allow not only a more efficient use of water resources, but will also mitigate against the risk of blackouts.