Yanjian Liao

Dr. Yanjian Liao


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
XLXing Liu
Xing Liu
MLMi Li
Mi Li
JZJiahui Zheng
Jiahui Zheng
XZXiaoling Zhang
Xiaoling Zhang
JZJunyi Zeng
Junyi Zeng
NHNing Hu
Ning Hu
The traditional quantitative analysis methods of ascorbic acid (AA), which require expensive equipment, a large amount of samples and professional technicians, are usually complex and time-consuming. A low-cost and high-efficiency AA detection device is reported in this work. It integrates a three-electrode sensor module prepared by screen printing technology, and a microfluidic chip with a finger-actuated micropump peeled from the liquid-crystal display (LCD) 3D printing resin molds. The AA detection process on this device is easy to operate. On-chip detection has been demonstrated to be 2.48 times more sensitive than off-chip detection and requires only a microliter-scale sample volume, which is much smaller than that required in traditional electrochemical methods. Experiments show that the sample and buffer can be fully mixed in the microchannel, which is consistent with the numerical simulation results wherein the mixing efficiency is greater than 90%. Commercially available tablets and beverages are also tested, and the result shows the reliability and accuracy of the device, demonstrating its broad application prospects in the field of point-of-care testing (POCT).

29 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
QWQiong Wang
Qiong Wang
JDJinan Deng
Jinan Deng
NHNing Hu
Ning Hu
YLYanjian Liao
Yanjian Liao
Jun YangJun Yang
Jun Yang
Blood coagulation tests are crucial in the clinical management of cardiovascular diseases and preoperative diagnostics. However, the widespread adoption of existing detection devices, such as thromboelastography (TEG) instruments, is hindered by their bulky size, prohibitive cost, and lengthy detection times. In contrast, magnetoelastic sensors, known for their low cost and rapid response, have garnered attention for their potential application in various coagulation tests. These sensors function by detecting resonant frequency shifts in response to changes in blood viscosity during coagulation. Nevertheless, the frequency-based detection approach necessitates continuous and precise frequency scanning, imposing stringent demands on equipment design, processing, and analytical techniques. In contrast, amplitude-based detection methods offer superior applicability in many sensing scenarios. This paper presents a comprehensive study on signal acquisition from magnetoelastic sensors. We elucidate the mathematical relationship between the resonant amplitude of the response signal and liquid viscosity, propose a quantitative viscosity measurement method based on the maximum amplitude of the signal, and construct a corresponding sensing device. The proposed method was validated using glycerol solutions, demonstrating a sensitivity of 13.83 V−1/Pa0.5s0.5Kg0.5m−1.5 and a detection limit of 0.0817 Pa0.5s0.5Kg0.5m−1.5. When applied to real-time monitoring of the coagulation process, the resulting coagulation curves and maximum amplitude (MA) parameters exhibited excellent consistency with standard TEG results (R2 values of 0.9552 and 0.9615, respectively). Additionally, other TEG parameters, such as R-time, K-time, and α-angle, were successfully obtained, effectively reflecting viscosity changes during blood coagulation.