Qiong Wang

Dr. Qiong Wang

Chongqing City Management College
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
QWQiong Wang
Qiong Wang
WLWenman Li
Wenman Li
NHNing Hu
Ning Hu
XCXi Chen
Xi Chen
TFTing Fan
Ting Fan
Jun YangJun Yang
Jun Yang

16 January 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
QWQiong Wang
Qiong Wang
XZXiaoling Zhang
Xiaoling Zhang
TFTing Fan
Ting Fan
ZYZhong Yang
Zhong Yang
XCXi Chen
Xi Chen
Jun YangJun Yang
Jun Yang
A giant unilamellar vesicle (GUV), with similar properties to cellular membrane, has been widely studied. Electroformation with its simplicity and accessibility has become the most common method for GUV production. In this work, GUV electroformation in devices with traditional 3D and new 2D electrode structures were studied with respect to the applied electric field. An optimal frequency (10 kHz in the 3D and 1 kHz in the 2D systems) was found in each system. A positive correlation was found between GUV formation and applied voltage in the 3D electrode system from 1 to 10 V. In the 2D electrode system, the yield of the generated GUV increased first but decreased later as voltage increased. These phenomena were further confirmed by numerically calculating the load that the lipid film experienced from the generated electroosmotic flow (EOF). The discrepancy between the experimental and numerical results of the 3D electrode system may be because the parameters that were adopted in the simulations are quite different from those of the lipid film in experiments. The lipid film was not involved in the simulation of the 2D system, and the numerical results matched well with the experiments.

29 March 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
XCXi Chen
Xi Chen
QWQiong Wang
Qiong Wang
JDJinan Deng
Jinan Deng
NHNing Hu
Ning Hu
YLYanjian Liao
Yanjian Liao
Jun YangJun Yang
Jun Yang
Blood coagulation tests are crucial in the clinical management of cardiovascular diseases and preoperative diagnostics. However, the widespread adoption of existing detection devices, such as thromboelastography (TEG) instruments, is hindered by their bulky size, prohibitive cost, and lengthy detection times. In contrast, magnetoelastic sensors, known for their low cost and rapid response, have garnered attention for their potential application in various coagulation tests. These sensors function by detecting resonant frequency shifts in response to changes in blood viscosity during coagulation. Nevertheless, the frequency-based detection approach necessitates continuous and precise frequency scanning, imposing stringent demands on equipment design, processing, and analytical techniques. In contrast, amplitude-based detection methods offer superior applicability in many sensing scenarios. This paper presents a comprehensive study on signal acquisition from magnetoelastic sensors. We elucidate the mathematical relationship between the resonant amplitude of the response signal and liquid viscosity, propose a quantitative viscosity measurement method based on the maximum amplitude of the signal, and construct a corresponding sensing device. The proposed method was validated using glycerol solutions, demonstrating a sensitivity of 13.83 V−1/Pa0.5s0.5Kg0.5m−1.5 and a detection limit of 0.0817 Pa0.5s0.5Kg0.5m−1.5. When applied to real-time monitoring of the coagulation process, the resulting coagulation curves and maximum amplitude (MA) parameters exhibited excellent consistency with standard TEG results (R2 values of 0.9552 and 0.9615, respectively). Additionally, other TEG parameters, such as R-time, K-time, and α-angle, were successfully obtained, effectively reflecting viscosity changes during blood coagulation.

26 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
QWQiong Wang
Qiong Wang
XZXiaoling Zhang
Xiaoling Zhang
DYDanfen Yin
Danfen Yin
JDJinan Deng
Jinan Deng
Jun YangJun Yang
Jun Yang
NHNing Hu
Ning Hu
Cell separation plays an important role in the fields of analytical chemistry and biomedicine. To solve the blockage problem and improve the separation throughput in the traditional microstructure filtration-based separation approach, a continuous cell separation and collection approach via micropost array railing on a microfilter and negative dielectrophoresis combined chip is proposed. By tilting the micropost array at a certain angle, microparticles or cells enter the collection area under micropost array railing. The effects of the inclination angle of the micropost array and the electrode distance on the microparticle collection efficiency were investigated. Based on the optimized microfluidic chip structure, 37- and 16.3-μm particles were collected with 85% and 89% efficiencies, respectively. Additionally, algal cells were separated and collected by using the optimized microchip. The chip also had good separation and collection effects on biological samples, which effectively solved the blockage problem and improved the separation throughput, laying a foundation for subsequent microstructure filtration separation-based research and application.

27 May 2021 in Processes
Verified
Journal Article
Open access
PDF file
QWQiong Wang
Qiong Wang
NHNing Hu
Ning Hu
JLJincan Lei
Jincan Lei
QQQiurong Qing
Qiurong Qing
JHJing Huang
Jing Huang
Jun YangJun Yang
Jun Yang
Lipid vesicles, especially giant lipid vesicles (GLVs), are usually adopted as cell membrane models and their preparation has been widely studied. However, the effects of some nonelectrolytes on GLV formation have not been specifically studied so far. In this paper, the effects of the nonelectrolytes, including sucrose, glucose, sorbitol and ethanol, and their coexistence with sodium chloride, on the lipid hydration and GLV formation were investigated. With the hydration method, it was found that the sucrose, glucose and sorbitol showed almost the same effect. Their presence in the medium enhanced the hydrodynamic force on the lipid membranes, promoting the GLV formation. GLV formation was also promoted by the presence of ethanol with ethanol volume fraction in the range of 0 to 20 percent, but higher ethanol content resulted in failure of GLV formation. However, the participation of sodium chloride in sugar solution and ethanol solution stabilized the lipid membranes, suppressing the GLV formation. In addition, the ethanol and the sodium chloride showed the completely opposite effects on lipid hydration. These results could provide some suggestions for the efficient preparation of GLVs.

19 February 2026 in Biosensors
Verified
Journal Article
Open access
PDF file
MQMou Qiongyao
Mou Qiongyao
PZPeiyi Zhang
Peiyi Zhang
DLDaijing Li
Daijing Li
QWQiong Wang
Qiong Wang
Jun YangJun Yang
Jun Yang
Microfluidics-based preparation methods for cell-laden hydrogel microspheres are well-suited for large-scale comparative analysis of single or few cells. However, in existing studies, the preparation of cell-laden hydrogel microspheres and the cell culture process are typically separated, requiring the fabricated microspheres to be eluted and transferred from the preparation device to cell culture dishes or plates for cultivation. This transfer process can easily compromise sterility, while conventional cell culture methods consume more reagents and cause microsphere stacking, hindering single-cell observation and analysis. To address these issues, this paper presents an integrated microfluidic chip that sequentially enables droplet generation with cell encapsulation, gel droplet solidification, hydrogel microsphere trapping, and microsphere-based cell culture and analysis, facilitating the cultivation and observation of single or small numbers of cells. Integrating cell-laden microsphere preparation and 3D cell culture within a sealed chip structure reduces contamination risks associated with cell transfer, enables automation of multiple cell analysis workflows, and minimizes reagent and sample consumption. Using polydimethylsiloxane (PDMS) with good gas permeability and processability as the chip material, biocompatible fluorinated oil was selected as the oil phase for microsphere preparation. A mild sodium alginate-calcium ion gelation system was employed, where calcium ions were released under acidic conditions after droplet generation to trigger solidification, yielding uniform hydrogel microspheres. Under optimized conditions, the single-cell encapsulation efficiency for test samples of human myeloid leukemia cells (K562) was 33.8% ± 1.8%, with a size uniformity coefficient of variation (CV) reaching 3.85%. Cells encapsulated within hydrogel microspheres were cultured in 286 on-chip independent cell culture chambers, achieving >95% viability after 24 h.